In‐situ near infrared spectroscopy to monitor key analytes in mammalian cell cultivation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The use of in‐situ near infrared spectroscopy (NIRS) as a tool for monitoring four key analytes in a CHO‐K1 animal cell culture was investigated. Previous work using on‐line NIRS to monitor bioprocesses has involved its application ex‐situ where the analyzer is physically outside the fermentor, or to microbial bioprocesses. This novel application of NIRS to monitor analytes within an animal cell culture using a steam sterilizable in‐situ fiber optic probe is very important for furthering the use of NIRS within the bioprocessing industry. The method of calibration used to develop the models involved the use of large data sets so that all likely variation in stoichiometry was incorporated within the models. Successful models for glucose, lactate, glutamine, and ammonia were built with Standard Error of Predictions (SEP's) of 0.072 (g/L), 0.0144 (g/L), 0.308 (m M), and 0.036 (m M), respectively of the total concentration range. © 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 84: 13–19, 2003.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alison Arnold, S., Matheson, L., Harvey, L. M., & McNeil, B. (2001) · Biotechnology Letters · doi:10.1023/a:1010343828947 · Cited by 20 · cited 1×
“…1996; Macaloney et al. 1996, 1997), as well as rather more complicated (longer cultivation periods and non-Newtonian fluids) processes such as fungal bioprocesses (Vaidyanathan et al. 2001a; 2001b) and filamentous bacterial bioprocesses (Arnold et al. 2000, 2001; Vaidyanathan et al. 2000, 2001c).”
BackgroundSelf-citation
Cited by
A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies
Roggo, Y., Chalus, P., Maurer, L., Lema-Martinez, C., Edmond, A., & Jent, N. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.03.023 · Cited by 1,131
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
“This approach for generation of the calibration dataset and model validation has been successfully applied to NIR applications (Arnold et al., 2003; Card et al., 2008; Cervera et al., 2009).”
MethodBioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275
“fermentation monitoring because of interferences from stirring and gas bubbles [65], from temperature changes, aeration, and feeding [66], and from water and other sources of variability [67].”
BackgroundSoft sensors in bioprocessing: A status report and recommendations
Luttmann, R., Bracewell, D. G., Cornelissen, G., Gernaey, K. V., Glassey, J., Hass, V. C., Kaiser, C., Preusse, C., Striedner, G., & Mandenius, C. (2012) · Biotechnology Journal · doi:10.1002/biot.201100506 · Cited by 238
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
Metadata
- Authors
- Arnold, S. A., Crowley, J., Woods, N., Harvey, L. M., & McNeil, B.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2003-07-28
- Volume
- 84
- Issue
- 1
- Pages
- 13-19
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W1987572064
- Cited by
- 149
- References
- 1
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.