Development of a perfusion fed bioreactor for embryonic stem cell‐derived cardiomyocyte generation: Oxygen‐mediated enhancement of cardiomyocyte output
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Cell transplantation is emerging as a promising new approach to replace scarred, nonfunctional myocardium in a diseased heart. At present, however, generating the numbers of donor cardiomyocytes required to develop and test animal models is a major limitation. Embryonic stem (ES) cells may be a promising source for therapeutic applications, potentially providing sufficient numbers of functionally relevant cells for transplantation into a variety of organs. We developed a single‐step bioprocess for ES cell‐derived cardiomyocyte production that enables both medium perfusion and direct monitoring and control of dissolved oxygen. Implementation of the bioprocess required combining methods to prevent ES cell aggregation (hydrogel encapsulation) and to purify for cardiomyocytes from the heterogeneous cell populations (genetic selection), with medium perfusion in a controlled bioreactor environment. We used this bioprocess to investigate the effects of oxygen on cardiomyocyte generation. Parallel vessels (250 mL culture volume) were run under normoxic (20% oxygen tension) or hypoxic (4% oxygen tension) conditions. After 14 days of differentiation (including 5 days of selection), the cardiomyocyte yield per input ES cell achieved in hypoxic vessels was 3.77 ± 0.13, higher than has previously been reported. We have developed a bioprocess that improves the efficiency of ES cell‐derived cardiomyocyte production, and allows the investigation of bioprocess parameters on ES cell‐derived cardiomyogenesis. Using this system we have demonstrated that medium oxygen tension is a culture parameter that can be manipulated to improve cardiomyocyte yield. © 2005 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilineage embryonic hematopoiesis requires hypoxic ARNT activity
Adelman, D. M., Maltepe, E., & Simon, M. C. (1999) · Genes & Development · doi:10.1101/gad.13.19.2478 · Cited by 185
Cited by
Laflamme, M. A., Chen, K. Y., Naumova, A. V., Muskheli, V., Fugate, J. A., Dupras, S. K., Reinecke, H., Xu, C., Hassanipour, M., Police, S., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1327 · Cited by 2,206
Mummery, C. L., Zhang, J., Ng, E. S., Elliott, D. A., Elefanty, A. G., & Kamp, T. J. (2012) · Circulation Research · doi:10.1161/circresaha.110.227512 · Cited by 713
Engineered Microenvironments for Controlled Stem Cell Differentiation
Burdick, J. A., & Vunjak-Novakovic, G. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0131 · Cited by 485
“50,51 Another example is a similar system with medium recirculation for the expansion of neural mouse stem cells, shown to out-perform several nonperfused systems, including static culture, stirred flasks, and rotating bioreactors.”
Ungrin, M. D., Joshi, C., Nica, A., Bauwens, C., & Zandstra, P. W. (2008) · PLoS ONE · doi:10.1371/journal.pone.0001565 · Cited by 413
Self-citationCell Delivery Mechanisms for Tissue Repair
Mooney, D. J., & Vandenburgh, H. (2008) · Cell Stem Cell · doi:10.1016/j.stem.2008.02.005 · Cited by 357
Metadata
- Authors
- Bauwens, C., Yin, T., Dang, S., Peerani, R., & Zandstra, P. W.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2005-03-18
- Volume
- 90
- Issue
- 4
- Pages
- 452-461
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2104953790
- Cited by
- 149
- References
- 1
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a perfusion fed bioreactor for embryonic stem cell‐derived cardiomyocyte generation: Oxygen‐mediated enhancement of cardiomyocyte output. https://app.cochat.ai/papers/10.1002/bit.20445
- The paper
- Bauwens, C., Yin, T., Dang, S., Peerani, R., & Zandstra, P. W. (2005). Development of a perfusion fed bioreactor for embryonic stem cell‐derived cardiomyocyte generation: Oxygen‐mediated enhancement of cardiomyocyte output. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.20445
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.