A theoretical study of oxygen transfer including cell necrosis for the design of a bioartificial pancreas
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In an extravascular bioartificial pancreas (BAP), islet functions are probably limited by diffusive mass transfer and local consumption, leading to low oxygenation. A mathematical model based on finite elements and focusing on local oxygen transport in both the alginate core and the islets of Langerhans has been proposed to help design an efficient pancreas supply. It was possible to randomly localize islets in a hollow fiber at different densities, and the effects of hypoxia and necrosis were included in the mass transfer simulations. Thorough study of the numerical results first led to the analysis of several relevant parameters, such as necrosis factor and efficacy in terms of insulin secretion, as a way to optimize fiber geometry. The approach was then to calculate the number of islets that needed to be implanted in order to obtain a correct response in terms of insulin secretion. In most configurations, it was found to be much higher than that of ultimately functional islets, because of hypoxia and necrosis. Fiber length should thus be adjusted accordingly. Finally, we demonstrated that the compromise to be found between the reduction of the number of implanted islets and fiber length and diameter did not correspond to realistic hollow fiber systems. The alternative of using flat geometry was also envisaged with more optimistic feasibility assessments. Biotechnol. Bioeng. 2007;96:990–998. © 2006 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microencapsulated Islets as Bioartificial Endocrine Pancreas
Lim, F., & Sun, A. M. (1980) · Science · doi:10.1126/science.6776628 · Cited by 2,377 · cited 1×
“Extravascular BAPs with different shapes (e.g., beads (Darquy and Reach, 1985; De Vos et al., 1999; Lim and Sun, 1980), hollow fiber (Altman et al., 1981; Lacy et al., 1991), and chambers (Rafael et al., 1997; Suzuki et al., 1998; Theodorou and Howell, 1979)) have been developed to host pancreatic…”
Background
Cited by
Medical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
“) Besides, Dulong and Legallais [241,242] estimaed the relevant parameters of a bioartificial pancreas.”
BackgroundInfluentialAdvances in islet encapsulation technologies
Desai, T., & Shea, L. D. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.232 · Cited by 427
Scharp, D. W., & Marchetti, P. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.018 · Cited by 314
Injectable hydrogels for central nervous system therapy
Pakulska, M. M., Ballios, B. G., & Shoichet, M. S. (2012) · Biomedical Materials · doi:10.1088/1748-6041/7/2/024101 · Cited by 216
Challenges and emerging technologies in the immunoisolation of cells and tissues
Wilson, J. T., & Chaikof, E. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.034 · Cited by 198
Metadata
- Authors
- Dulong, J., & Legallais, C.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2006-08-08
- Volume
- 96
- Issue
- 5
- Pages
- 990-998
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2154778848
- Cited by
- 74
- References
- 1
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.