Engineered blood and lymphatic capillaries in 3‐D VEGF‐fibrin‐collagen matrices with interstitial flow
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In vitro endothelial cell organization into capillaries is a long standing challenge of tissue engineering. We recently showed the utility of low level interstitial flow in guiding the organization of endothelial cells through a 3‐D fibrin matrix‐containing covalently bound vascular endothelial growth factor (VEGF). Here this synergistic phenomenon was extended to explore the effects of matrix composition on in vitro capillary morphogenesis of human blood versus lymphatic endothelial cells (BECs and LECs). Different mixtures of fibrin and collagen were used in conjunction with constant concentrations of matrix‐bound VEGF and slow interstitial flow over 10 days. Interestingly, the BECs and LECs each showed a distinct preference in terms of organization for matrix composition: LECs organized the most extensively in a fibrin‐only matrix, while BEC organization was optimized in the compliant collagen‐containing matrices. Furthermore, the BECs and LECs produced architecturally different structures; while BECs organized in thick, branched networks containing wide lumen, the LECs were elongated into slender, overlapping networks with fine lumen. These data demonstrate the importance of the 3‐D matrix composition in facilitating and coordinating BEC and LEC capillary morphogenesis, which is important for in vitro vascularization of engineered tissues. Biotechnol. Bioeng. 2007;96: 167–176. © 2006 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biology of VEGF and its receptors
Ferrara, N., Gerber, H.-P., & LeCouter, J. (2003) · Nature Medicine · doi:10.1038/nm0603-669 · Cited by 9,591 · cited 7×
“In addition, when applied as an implanted fibrin matrix in vivo, this matrix-binding variant of VEGF121 produced patent capillary vessels as opposed to the leaky variety elicited by soluble VEGF121 in the same system (Ehrbar et al., 2004).”
BackgroundInfluentialSinger, A. J., & Clark, R. A. F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909023411006 · Cited by 6,106
Cited by
3D bioprinting of tissues and organs for regenerative medicine
Vijayavenkataraman, S., Yan, W.-C., Lu, W. F., Wang, C.-H., & Fuh, J. Y. H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.004 · Cited by 630
Interstitial Flow and Its Effects in Soft Tissues
Swartz, M. A., & Fleury, M. E. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151850 · Cited by 598
Self-citationProvenzano, P. P., & Keely, P. J. (2011) · Journal of Cell Science · doi:10.1242/jcs.067009 · Cited by 494
In Vitro Perfused Human Capillary Networks
Moya, M. L., Hsu, Y.-H., Lee, A. P., Hughes, C. C. W., & George, S. C. (2013) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0430 · Cited by 387
A driving force for change: interstitial flow as a morphoregulator
Rutkowski, J. M., & Swartz, M. A. (2007) · Trends in Cell Biology · doi:10.1016/j.tcb.2006.11.007 · Cited by 302
Self-citation
Metadata
- Authors
- Helm, C. E., Zisch, A., & Swartz, M. A.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2006-08-31
- Volume
- 96
- Issue
- 1
- Pages
- 167-176
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2150305156
- Cited by
- 143
- References
- 2
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Engineered blood and lymphatic capillaries in 3‐D VEGF‐fibrin‐collagen matrices with interstitial flow. https://app.cochat.ai/papers/10.1002/bit.21185
- The paper
- Helm, C. E., Zisch, A., & Swartz, M. A. (2007). Engineered blood and lymphatic capillaries in 3‐D VEGF‐fibrin‐collagen matrices with interstitial flow. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.21185
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.