Comparisons of optical pH and dissolved oxygen sensors with traditional electrochemical probes during mammalian cell culture
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Small‐scale upstream bioprocess development often occurs in flasks and multi‐well plates. These culturing platforms are often not equipped to accurately monitor and control critical process parameters; thus they may not yield conditions representative of manufacturing. In response, we and others have developed optical sensors that enable small‐scale process monitoring. Here we have compared two parameters critical to control in industrial cell culture, pH and dissolved oxygen (DO), measured with our optical sensors versus industrially accepted electrochemical probes. For both optical sensors, agreement with the corresponding electrochemical probe was excellent. The Pearson Correlations between the optical sensors and electrochemical probes were 98.7% and 99.7%, for DO and pH, respectively. Also, we have compared optical pH sensor performance in regular (320 mOsm/kg) and high‐osmolality (450 mOsm/kg) cell culture media to simulate the increase in osmolality in pH‐controlled cultures. Over a pH range of 6.38–7.98 the average difference in pH readings in the two media was 0.04 pH units. In summary, we have demonstrated that these optical sensors agree well with standard electrochemical probes. The accuracy of the optical probes demonstrates their ability to detect potential parameter drift that could have significant impact on growth, production kinetics, and protein product quality. We have also shown that an increase in osmolality that could result from controlling pH or operating the reactor in fed‐batch mode has an insignificant impact on the functionality of the pH patches. Biotechnol. Bioeng. 2007;97: 833–841. © 2007 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Borys, M. C., Linzer, D. I. H., & Papoutsakis, E. T. (1993) · Nature Biotechnology · doi:10.1038/nbt0693-720 · Cited by 171 · cited 3×
“, 1998; Ozturk and Palsson, 1990) and pH (Borys et al., 1993; Hayter et al., 1992; Muthing et al., 2003; Ozturk and Palsson, 1991).”
BackgroundInfluentialpH, pCO 2 , and Temperature Effect on R‐Adenovirus Production
Jardon, M., & Garnier, A. (2003) · Biotechnology Progress · doi:10.1021/bp025585a · Cited by 47
Cited by
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Indicators for optical oxygen sensors
Quaranta, M., Borisov, S. M., & Klimant, I. (2012) · Bioanalytical Reviews · doi:10.1007/s12566-012-0032-y · Cited by 452
Combinatorial and High-Throughput Development of Sensing Materials: The First 10 Years
Potyrailo, R. A., & Mirsky, V. M. (2008) · Chemical Reviews · doi:10.1021/cr068127f · Cited by 258
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
“They showed that optical sensors enabled small-scale monitoring and that the measurement results are comparable to standard electrochemical probes [95].”
BackgroundModern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Metadata
- Authors
- Hanson, M. A., Ge, X., Kostov, Y., Brorson, K. A., Moreira, A. R., & Rao, G.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2007-05-24
- Volume
- 97
- Issue
- 4
- Pages
- 833-841
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2027556857
- Cited by
- 106
- References
- 2
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.