Microfluidic biochip for the perifusion of precision‐cut rat liver slices for metabolism and toxicology studies
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Early detection of kinetic, metabolic, and toxicity (ADME‐Tox) profiles for new drug candidates is of crucial importance during drug development. This article describes a novel in vitro system for the incubation of precision‐cut liver slices (PCLS) under flow conditions, based on a poly(dimethylsiloxane) (PDMS) device containing 25‐µL microchambers for integration of the slices. The microdevice is coupled to a perifusion system, which enables a constant delivery of nutrients and oxygen and a continuous removal of waste products. Both a highly controlled incubation environment and high metabolite detection sensitivity could be achieved using microfluidics. Liver slices were viable for at least 24 h in the microdevice. The compound, 7‐ethoxycoumarin (7‐EC), was chosen to test metabolism, since its metabolism includes both phase I and phase II metabolism and when tested in the conventional well plate system, correlates well with the in vivo situation (De Kanter et al. 2004. Xenobiotica 34(3): 229–241.). The metabolic rate of 7‐EC was found to be 214 ± 5 pmol/min/mg protein in the microdevice, comparable to well plates, and was constant over time for at least 3 h. This perifusion system better mimics the in vivo situation, and has the potential to significantly contribute to drug metabolism and toxicology studies of novel chemical entities. Biotechnol. Bioeng. 2010;105: 184–194. © 2009 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Can the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Cited by
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Self-citationde Graaf, I. A. M., Olinga, P., de Jager, M. H., Merema, M. T., de Kanter, R., van de Kerkhof, E. G., & Groothuis, G. M. M. (2010) · Nature Protocols · doi:10.1038/nprot.2010.111 · Cited by 411
Self-citationMarx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“…of architecture – the entire liver lobule – has not yet been reached, but a chip-based microfluidic approach to containing a major part of a liver lobule has been made by van Midwoud and colleagues (van Midwoud et al., 2010a), who cultivated 3 mg of liver slice tissue in a microfluidic chip (Fig.”
van Midwoud, P. M., Janse, A., Merema, M. T., Groothuis, G. M. M., & Verpoorte, E. (2012) · Analytical Chemistry · doi:10.1021/ac300771z · Cited by 274
Self-citationvan Midwoud, P. M., Merema, M. T., Verpoorte, E., & Groothuis, G. M. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00043d · Cited by 203
Self-citation
Metadata
- Authors
- van Midwoud, P. M., Groothuis, G. M. M., Merema, M. T., & Verpoorte, E.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2009-10-08
- Volume
- 105
- Issue
- 1
- Pages
- 184-194
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2139542130
- Cited by
- 135
- References
- 2
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.