CoChat

Perfusion of 3D encapsulated hepatocytes—A synergistic effect enhancing long‐term functionality in bioreactors

Tostões, Rui M., Leite, Sofia B., Miranda, Joana P., Sousa, Marcos, Wang, Daniel I.C., Carrondo, Manuel J.T., Alves, Paula M. · 2011 · Biotechnology and Bioengineering
Cited by 86

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Long‐term primary cultures of hepatocytes are essential for bioartificial liver (BAL) devices and to reduce and replace animal tests in lead candidate optimization in drug discovery and toxicology tests. The aim of this work was to improve bioreactor cultures of hepatocyte spheroids by adding a more physiological perfusion feeding regime to these bioreactor systems. A continuous perfusion feeding was compared with 50% medium replacement (routinely used for in vitro tests) at the same dilution rate, 0.125 day−1, for three operative weeks. Perfusion feeding led to a 10‐fold improvement in albumin synthesis in bioreactors containing non‐encapsulated hepatocyte spheroids; no significant improvement was observed in phase I drug metabolizing activity. When ultra high viscous alginate encapsulated spheroids were cultured in perfusion, urea synthesis, phase I drug metabolizing activity and oxygen consumption had a threefold improvement over the 50% medium replacement regime; albumin production was the same for both feeding regimes. The effective diffusion of albumin in the alginate capsules was 7.75.10−9 cm 2 s−1 and no diffusion limitation for this protein was observed using these alginate capsules under our operational conditions. In conclusion, perfusion feeding coupled with alginate encapsulation of hepatocyte spheroids showed a synergistic effect with a threefold improvement in three independent liver‐specific functions of long‐term hepatocyte spheroid cultures. Biotechnol. Bioeng. 2011; 108:41–49. © 2010 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.22920

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 86

Metadata

Authors
Tostões, R. M., Leite, S. B., Miranda, J. P., Sousa, M., Wang, D. I. C., Carrondo, M. J. T., & Alves, P. M.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2010-09-30
Volume
108
Issue
1
Pages
41-49
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2078388258
Cited by
86
References
6
FWCI
9.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Perfusion of 3D encapsulated hepatocytes—A synergistic effect enhancing long‐term functionality in bioreactors. https://app.cochat.ai/papers/10.1002/bit.22920
The paper
Tostões, R. M., Leite, S. B., Miranda, J. P., Sousa, M., Wang, D. I. C., Carrondo, M. J. T., & Alves, P. M. (2011). Perfusion of 3D encapsulated hepatocytes—A synergistic effect enhancing long‐term functionality in bioreactors. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.22920

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.