Synchronous fluorescence spectroscopy as a novel tool to enable PAT applications in bioprocesses
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this work, synchronous fluorescence spectroscopy (SFS) is evaluated as a new tool for real‐time bioprocess monitoring of animal cell cultures. This technique presents several advantages over the traditional two‐dimensional (2D) fluorometry since it provides data on various fluorescent compounds in a single spectrum, showing improved peak resolution and recording speed. Bioreactor cultures of three monoclonal antibody‐producing CHO cell lines were followed in situ by both 2D and synchronous fluorometry techniques. The time profiles of the main spectral features in each data type present some differences, but principal component analysis indicated both as containing enough information to distinguish the cultures. Partial least squares regression models were then independently developed for viable cell density and antibody levels on the basis of the different fluorescence signals recorded, hiding half of the dataset for subsequent validation purposes. Regardless of the signal used, model predictions fit very well the off‐line measurements; still, the synchronous spectra collected at a wavelength difference of 20 nm allowed comparable and superior performances for cell density and antibody titer, respectively, with validation accuracies higher than 91%. Therefore, SFS compares favorably with the traditional 2D approach, becoming an improved, faster option for real‐time monitoring of cells and product titer over culture time. The readiness in data acquisition facilitates the design of process control strategies meeting the requirements of a PAT application. Biotechnol. Bioeng. 2011; 108:1852–1861. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-Dimensional Fluorescence Spectroscopy: A New Tool for On-Line Bioprocess Monitoring
Marose, S., Lindemann, C., & Scheper, T. (1998) · Biotechnology Progress · doi:10.1021/bp970124o · Cited by 190
Cited by
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
Modern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Pais, D. A. M., Portela, R. M. C., Carrondo, M. J. T., Isidro, I. A., & Alves, P. M. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27117 · Cited by 36
Self-citationMishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“[76] used synchronous fluorescence spectroscopy (SFS) as a new tool for real-time monitoring of animal cell cultures in bioprocesses.”
Metadata
- Authors
- Teixeira, A. P., Duarte, T. M., Carrondo, M. J. T., & Alves, P. M.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2011-03-24
- Volume
- 108
- Issue
- 8
- Pages
- 1852-1861
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2142001565
- Cited by
- 39
- References
- 1
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Synchronous fluorescence spectroscopy as a novel tool to enable PAT applications in bioprocesses. https://app.cochat.ai/papers/10.1002/bit.23131
- The paper
- Teixeira, A. P., Duarte, T. M., Carrondo, M. J. T., & Alves, P. M. (2011). Synchronous fluorescence spectroscopy as a novel tool to enable PAT applications in bioprocesses. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.23131
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.