CoChat

Collisional fragmentation of central carbon metabolites in LC‐MS/MS increases precision of 13C metabolic flux analysis

Open access
Rühl, Martin, Rupp, Beat, Nöh, Katharina, Wiechert, Wolfgang, Sauer, Uwe, Zamboni, Nicola · 2012 · Biotechnology and Bioengineering
Cited by 97

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Experimental determination of fluxes by 13 C‐tracers relies on detection of 13 C‐patterns in metabolites or by‐products. In the field of 13 C metabolic flux analysis, the most recent developments point toward recording labeling patterns by liquid chromatography (LC)‐mass spectrometry (MS)/MS directly in intermediates in central carbon metabolism (CCM) to increase temporal resolution. Surprisingly, the flux studies published so far with LC‐MS measurements were based on intact metabolic intermediates—thus neglected the potential benefits of using positional information to improve flux estimation. For the first time, we exploit collisional fragmentation to obtain more fine‐grained 13 C‐data on intermediates of CCM and investigate their impact in 13 C metabolic flux analysis. For the case study of Bacillus subtilis grown in mineral medium with 13 C‐labeled glucose, we compare the flux estimates obtained by iterative isotopologue balancing of 13 C‐data obtained either by LC‐MS/MS for solely intact intermediates or LC‐MS/MS for intact and fragmented intermediates of CCM. We show that with LC‐MS/MS data, fragment information leads to more precise estimates of fluxes in pentose phosphate pathway, glycolysis, and to the tricarboxylic acid cycle. Additionally, we present an efficient analytical strategy to rapidly acquire large sets of 13 C‐patterns by tandem MS, and an in‐depth analysis of the collisional fragmentation of primary intermediates. In the future, this catalogue will enable comprehensive in silico calculability analyses to identify the most sensitive measurements and direct experimental design. Biotechnol. Bioeng. 2012; 109:763–771. © 2011 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.24344

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 97

Metadata

Authors
Rühl, M., Rupp, B., Nöh, K., Wiechert, W., Sauer, U., & Zamboni, N.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2011-10-28
Volume
109
Issue
3
Pages
763-771
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2008204246
Cited by
97
References
1
FWCI
3.53
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Collisional fragmentation of central carbon metabolites in LC‐MS/MS increases precision of 13C metabolic flux analysis. https://app.cochat.ai/papers/10.1002/bit.24344
The paper
Rühl, M., Rupp, B., Nöh, K., Wiechert, W., Sauer, U., & Zamboni, N. (2012). Collisional fragmentation of central carbon metabolites in LC‐MS/MS increases precision of 13C metabolic flux analysis. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.24344

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.