A tool for selective inline quantification of co‐eluting proteins in chromatography using spectral analysis and partial least squares regression
The DOI matches its Crossref record.
Abstract
Selective quantification of co‐eluting proteins in chromatography is usually performed by offline analytics. This is time‐consuming and can lead to late detection of irregularities in chromatography processes. To overcome this analytical bottleneck, a methodology for selective protein quantification in multicomponent mixtures by means of spectral data and partial least squares regression was presented in two previous studies. In this paper, a powerful integration of software and chromatography hardware will be introduced that enables the applicability of this methodology for a selective inline quantification of co‐eluting proteins in chromatography. A specific setup consisting of a conventional liquid chromatography system, a diode array detector, and a software interface to Matlab® was developed. The established tool for selective inline quantification was successfully applied for a peak deconvolution of a co‐eluting ternary protein mixture consisting of lysozyme, ribonuclease A, and cytochrome c on SP Sepharose FF. Compared to common offline analytics based on collected fractions, no loss of information regarding the retention volumes and peak flanks was observed. A comparison between the mass balances of both analytical methods showed, that the inline quantification tool can be applied for a rapid determination of pool yields. Finally, the achieved inline peak deconvolution was successfully applied to make product purity‐based real‐time pooling decisions. This makes the established tool for selective inline quantification a valuable approach for inline monitoring and control of chromatographic purification steps and just in time reaction on process irregularities. Biotechnol. Bioeng. 2014;111: 1365–1373. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
Bioprocess Control: Current Progress and Future Perspectives
Rathore, A. S., Mishra, S., Nikita, S., & Priyanka, P. (2021) · Life · doi:10.3390/life11060557 · Cited by 141
Rolinger, L., Rüdt, M., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02407-z · Cited by 126
Self-citationOpportunities and challenges of real-time release testing in biopharmaceutical manufacturing
Jiang, M., Severson, K. A., Love, J. C., Madden, H., Swann, P., Zang, L., & Braatz, R. D. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26383 · Cited by 118
Helgers, H., Schmidt, A., Lohmann, L. J., Vetter, F. L., Juckers, A., Jensch, C., Mouellef, M., Zobel-Roos, S., & Strube, J. (2021) · Processes · doi:10.3390/pr9010172 · Cited by 52
Rolinger, L., Rüdt, M., Diehm, J., Chow-Hubbertz, J., Heitmann, M., Schleper, S., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02318-8 · Cited by 46
Self-citation
Metadata
- Authors
- Brestrich, N., Briskot, T., Osberghaus, A., & Hubbuch, J.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2014-02-13
- Volume
- 111
- Issue
- 7
- Pages
- 1365-1373
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2102791608
- Cited by
- 60
- References
- 0
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.