Shuttle‐mediated nanoparticle transport across an in vitro brain endothelium under flow conditions
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The blood brain barrier (BBB) represents a challenge in the development of new nano‐delivery systems able to reach the central nervous system (CNS). In order to test the efficacy of these nanocarriers, it is fundamental to use in vitro models that resemble the in vivo cell culture conditions. Here, we demonstrate for the first time the ability of a membranotropic peptide, namely gH625, to transport a cargo—acting as a shuttle—across the BBB layer under flow conditions that mimic the blood flow rate. To this aim, a BBB microfluidic device was designed based on a transparent polyester porous membrane sandwiched between a top and a bottom overlying channel made of poly(methyl methacrylate) (PMMA). Our data clearly indicate that this microfluidic system allows the growth of brain endothelial bEnd.3 cells and the formation of a confluent layer at 7 days of culture that hinders the passage of nanoparticles compared to porous membrane alone. The device was validated at a 5 μL/min working flow rate, where the capability of the model to remain intact after nanoparticle passage was shown. Very interestingly, the decoration with the gH625 peptide enhances the adhesion of nanoparticles to the endothelial layer and the BBB crossing in flow conditions, thus confirming the efficacy of the gH625 as a delivery platform to the brain. Biotechnol. Bioeng. 2017;114: 1087–1095. © 2016 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834 · cited 2×
“These organs-on-chips have the potential to be used as human-relevant disease models, and additionally provide detailed insights into drug effects (Huh et al., 2011; van der Meer et al., 2010).”
BackgroundLuissint, A.-C., Artus, C., Glacial, F., Ganeshamoorthy, K., & Couraud, P.-O. (2012) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-9-23 · Cited by 654 · cited 1×
“Moreover, this flow rate value corresponding to 0.15 dynes/cm2, fell in the physiological range (0.01–10 dynes/ cm2) (Luissint et al., 2012).”
BackgroundInfluential
Cited by
Xuan, L., Ju, Z., Skonieczna, M., Zhou, P., & Huang, R. (2023) · MedComm · doi:10.1002/mco2.327 · Cited by 807
Development of Polymeric Nanoparticles for Blood–Brain Barrier Transfer—Strategies and Challenges
Zhang, W., Mehta, A., Tong, Z., Esser, L., & Voelcker, N. H. (2021) · Advanced Science · doi:10.1002/advs.202003937 · Cited by 430
Cell Penetrating Peptides as Molecular Carriers for Anti-Cancer Agents
Borrelli, A., Tornesello, A., Tornesello, M., & Buonaguro, F. (2018) · Molecules · doi:10.3390/molecules23020295 · Cited by 295
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
In Vitro Models of Biological Barriers for Nanomedical Research
Carton, F., & Malatesta, M. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23168910 · Cited by 34
Metadata
- Authors
- Falanga, A. P., Pitingolo, G., Celentano, M., Cosentino, A., Melone, P., Vecchione, R., Guarnieri, D., & Netti, P. A.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2016-11-24
- Volume
- 114
- Issue
- 5
- Pages
- 1087-1095
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2553821176
- Cited by
- 64
- References
- 2
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shuttle‐mediated nanoparticle transport across an in vitro brain endothelium under flow conditions. https://app.cochat.ai/papers/10.1002/bit.26221
- The paper
- Falanga, A. P., Pitingolo, G., Celentano, M., Cosentino, A., Melone, P., Vecchione, R., Guarnieri, D., & Netti, P. A. (2017). Shuttle‐mediated nanoparticle transport across an in vitro brain endothelium under flow conditions. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.26221
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.