CoChat

Determination of critical shear stress for maturation of human pluripotent stem cell‐derived endothelial cells towards an arterial subtype

Open access
Arora, Seep, Lam, Adele Jing Ying, Cheung, Christine, Yim, Evelyn K. F., Toh, Yi‐Chin · 2019 · Biotechnology and Bioengineering
Cited by 46

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Human pluripotent stem cell‐derived endothelial cells (hPSC‐ECs) present an attractive alternative to primary EC sources for vascular grafting. However, there is a need to mature them towards either an arterial or venous subtype. A vital environmental factor involved in the arteriovenous specification of ECs during early embryonic development is fluid shear stress; therefore, there have been attempts to employ adult arterial shear stress conditions to mature hPSC‐ECs. However, hPSC‐ECs are naïve to fluid shear stress, and their shear responses are still not well understood. Here, we used a multiplex microfluidic platform to systematically investigate the dose‐time shear responses on hPSC‐EC morphology and arterial‐venous phenotypes over a range of magnitudes coincidental with physiological levels of embryonic and adult vasculatures. The device comprised of six parallel cell culture chambers that were individually linked to flow‐setting resistance channels, allowing us to simultaneously apply shear stress ranging from 0.4 to 15 dyne/cm 2. We found that hPSC‐ECs required up to 40 hr of shear exposure to elicit a stable phenotypic change. Cell alignment was visible at shear stress <1 dyne/cm 2, which was independent of shear stress magnitude and duration of exposure. We discovered that the arterial markers NOTCH1 and EphrinB2 exhibited a dose‐dependent increase in a similar manner beyond a threshold level of 3.8 dyne/cm 2, whereas the venous markers COUP‐TFII and EphB4 expression remained relatively constant across different magnitudes. These findings indicated that hPSC‐ECs were sensitive to relatively low magnitudes of shear stress, and a critical level of ~4 dyne/cm 2 was sufficient to preferentially enhance their maturation into an arterial phenotype for future vascular tissue engineering applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.26910

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 46

Metadata

Authors
Arora, S., Lam, A. J. Y., Cheung, C., Yim, E. K. F., & Toh, Y.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2019-01-23
Volume
116
Issue
5
Pages
1164-1175
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2907949444
Cited by
46
References
3
FWCI
1.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of critical shear stress for maturation of human pluripotent stem cell‐derived endothelial cells towards an arterial subtype. https://app.cochat.ai/papers/10.1002/bit.26910
The paper
Arora, S., Lam, A. J. Y., Cheung, C., Yim, E. K. F., & Toh, Y. (2019). Determination of critical shear stress for maturation of human pluripotent stem cell‐derived endothelial cells towards an arterial subtype. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.26910

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.