Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Multicentre phase II trial of near-infrared imaging in elective colorectal surgery

Open access
Ris, F, Liot, E, Buchs, N C, Kraus, R, Ismael, G, Belfontali, V, Douissard, J, Cunningham, C, Lindsey, I, Guy, R, Jones, O, George, B, Morel, P, Mortensen, N J, Hompes, R, Cahill, R A·2018·British Journal of Surgery

Abstract

Background: Decreasing anastomotic leak rates remain a major goal in colorectal surgery. Assessing intraoperative perfusion by indocyanine green (ICG) with near-infrared (NIR) visualization may assist in selection of intestinal transection level and subsequent anastomotic vascular sufficiency. This study examined the use of NIR-ICG imaging in colorectal surgery. Methods: This was a prospective phase II study (NCT02459405) of non-selected patients undergoing any elective colorectal operation with anastomosis over a 3-year interval in three tertiary hospitals. A standard protocol was followed to assess NIR-ICG perfusion before and after anastomosis construction in comparison with standard operator visual assessment alone. Results: Five hundred and four patients (median age 64 years, 279 men) having surgery for neoplastic (330) and benign (174) pathology were studied. Some 425 operations (85·3 per cent) were started laparoscopically, with a conversion rate of 5·9 per cent. In all, 220 patients (43·7 per cent) underwent high anterior resection or reversal of Hartmann's operation, and 90 (17·9 per cent) low anterior resection. ICG angiography was achieved in every patient, with a median interval of 29 s to visualization of the signal after injection. NIR-ICG assessment resulted in a change in the site of bowel division in 29 patients (5·8 per cent) with no subsequent leaks in these patients. Leak rates were 2·4 per cent overall (12 of 504), 2·6 per cent for colorectal anastomoses and 3 per cent for low anterior resection. When NIR-ICG imaging was used, the anastomotic leak rates were lower than those in the participating centres from over 1000 similar operations performed with identical technique but without NIR-ICG technology. Conclusion: Routine NIR-ICG assessment in patients undergoing elective colorectal surgery is feasible. NIR-ICG use may change intraoperative decisions, which may lead to a reduction in anastomotic leak rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bjs.10844

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 204

Metadata

Authors
Ris, F., Liot, E., Buchs, N. C., Kraus, R., Ismael, G., Belfontali, V, Douissard, J., Cunningham, C., Lindsey, I., Guy, R., Jones, O., George, B., Morel, P., Mortensen, N. J., Hompes, R., & Cahill, R. A.
Venue
British Journal of Surgery
Published
2018-04-16
Volume
105
Issue
10
Pages
1359-1367
ISSN
  • 0007-1323 (ISSN-L)
  • 1365-2168
OpenAlex
W2810267871
Cited by
204
References
1
FWCI
17.95
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.