The DOI matches its Crossref record.
Vascularization of small liver metastases
Abstract
The portal vein contributes little to the blood supply of established liver metastases in the presence of a patent hepatic artery. However, its role in the perfusion of early metastatic liver disease remains controversial. We have quantified the relative contribution of the portal vein and hepatic artery to the internal circulation of small liver tumours. These studies were conducted in a new rat model of liver metastases generated by the intraportal injection of cultured tumour spheroids. A total of 633 lesions were studied in 18 animals using radioisotope tracer microspheres. Nodules ranged from 0·5 to 6·0 mm in diameter, 92 per cent being 3·0 mm or less. The ratio of radioactivity in tumour compared with normal tissue (T:N ratio) was determined after simultaneously injecting microspheres into the portal and arterial circulation of each animal. The mean hepatic artery T:N ratio was significantly greater than that of the portal vein for all tumour sizes studied (P < 0·01). Nodules 0·5 mm in diameter had a mean (s.e.m.) hepatic artery T:N ratio of 1·50 (0·12) in comparison with a mean portal vein ratio of 0·13 (0·04). Tumour nodules 2·0 mm in diameter had a mean (s.e.m.) hepatic artery T:N ratio of 1·26 (0·11) in comparison with a mean portal vein ratio of 0·06 (0·01). The overall T:N ratio for both routes decreased with increasing tumour size. These results indicate that hepatic tumours as small as 0·5 mm already have an established internal vasculature perfused predominantly by the hepatic artery. In contrast, the portal vein contributes insignificantly to the internal perfusion of these lesions. These results have significant implications for adjuvant locoregional therapy in gastrointestinal cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical applications of magnetic nanoparticles for hyperthermia
Thiesen, B., & Jordan, A. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730802104757 · Cited by 829
Magnetically mediated hyperthermia: current status and future directions
Moroz, P., Jones, S. K., & Gray, B. N. (2002) · International Journal of Hyperthermia · doi:10.1080/02656730110108785 · Cited by 538
Self-citationGray, B., Van Hazel, G., Hope, M., Burton, M., Moroz, P., Anderson, J., & Gebski, V. (2001) · Annals of Oncology · doi:10.1023/a:1013569329846 · Cited by 526
Self-citationLorenz, M., Müller, H.-H., Schramm, H., Gassel, H.-J., Rau, H.-G., Ridwelski, K., Hauss, J., Stieger, R., Jauch, K.-W., Bechstein, W. O., et al. (1998) · Annals of Surgery · doi:10.1097/00000658-199812000-00006 · Cited by 356
Kokudo, N., Tada, K., Seki, M., Ohta, H., Azekura, K., Ueno, M., Ohta, K., Yamaguchi, T., Matsubara, T., Takahashi, T., et al. (2001) · Hepatology · doi:10.1053/jhep.2001.26513 · Cited by 339
Metadata
- Authors
- Archer, S. G., & Gray, B. N.
- Venue
- Journal of British Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 1989-06-01
- Volume
- 76
- Issue
- 6
- Pages
- 545-548
- ISSN
- 0007-1323 (ISSN-L)
- 1365-2168
- OpenAlex
- W2050864654
- Cited by
- 158
- References
- 0
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vascularization of small liver metastases. https://app.cochat.ai/papers/10.1002/bjs.1800760607
- The paper
- Archer, S. G., & Gray, B. N. (1989). Vascularization of small liver metastases. Journal of British Surgery. https://doi.org/10.1002/bjs.1800760607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.