CoChat

Intraoperative fluorescence-based enhanced reality laparoscopic real-time imaging to assess bowel perfusion at the anastomotic site in an experimental model

Open access
Diana, M, Agnus, V, Halvax, P, Liu, Y -Y, Dallemagne, B, Schlagowski, A -I, Geny, B, Diemunsch, P, Lindner, V, Marescaux, J · 2015 · British Journal of Surgery
Cited by 130

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Fluorescence videography is a promising technique for assessing bowel perfusion. Fluorescence-based enhanced reality (FLER) is a novel concept, in which a dynamic perfusion cartogram, generated by computer analysis, is superimposed on to real-time laparoscopic images. The aim of this experimental study was to assess the accuracy of FLER in detecting differences in perfusion in a small bowel resection–anastomosis model. Methods: A small bowel ischaemic segment was created laparoscopically in 13 pigs. Animals were allocated to having anastomoses performed at either low perfusion (25 per cent; n = 7) or high perfusion (75 per cent; n = 6), as determined by FLER analysis. Capillary lactate levels were measured in blood samples obtained by serosal puncturing in the ischaemic area, resection lines and vascularized areas. Pathological inflammation scoring of the anastomosis was carried out. Results: Lactate levels in the ischaemic area (mean(s.d.) 5·6(2·8) mmol/l) were higher than those in resection lines at 25 per cent perfusion (3·7(1·7) mmol/l; P = 0·010) and 75 per cent perfusion (2·9(1·3) mmol/l; P < 0·001), and higher than levels in vascular zones (2·5(1·0) mmol/l; P < 0·001). Lactate levels in resection lines with 75 per cent perfusion were lower than those in lines with 25 per cent perfusion (P < 0·001), and similar to those in vascular zones (P = 0·188). Levels at resection lines with 25 per cent perfusion were higher than those in vascular zones (P = 0·001). Mean(s.d.) global inflammation scores were higher in the 25 per cent perfusion group compared with the 75 per cent perfusion group for mucosa/submucosa (2·1(0·4) versus 1·2(0·4); P = 0·003) and serosa (1·8(0·4) versus 0·8(0·8); P = 0·014). A ratio of preanastomotic lactate levels in the ischaemic area relative to the resection lines of 2 or less was predictive of a more severe inflammation score. Conclusion: In an experimental model, FLER appeared accurate in discriminating bowel perfusion levels. Surgical relevanceClinical assessment has limited accuracy in evaluating bowel perfusion before anastomosis. Fluorescence videography estimates intestinal perfusion based on the fluorescence intensity of injected fluorophores, which is proportional to bowel vascularization. However, evaluation of fluorescence intensity remains a static and subjective measure.Fluorescence-based enhanced reality (FLER) is a dynamic fluorescence videography technique integrating near-infrared endoscopy and specific software. The software generates a virtual perfusion cartogram based on time to peak fluorescence, which can be superimposed on to real-time laparoscopic images. This experimental study demonstrates the accuracy of FLER in detecting differences in bowel perfusion in a survival model of laparoscopic small bowel resection–anastomosis, based on biochemical and histopathological data.It is concluded that real-time imaging of bowel perfusion is easy to use and accurate, and should be translated into clinical use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bjs.9725

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 13

  1. Karliczek, 2009, Surgeons lack predictive accuracy for anastomotic leakage in gastrointestinal surgery, Int J Colorectal Dis, 24, 569, 10.1007/s00384-009-0658-6 · DOI · Paper page
  2. Nachiappan, 2014, Intraoperative assessment of colorectal anastomotic integrity: a systematic review, Surg Endosc, 28, 2513, 10.1007/s00464-014-3520-z · DOI
  3. Carus, 2012, Laparoscopic fluorescence angiography with indocyanine green to control the perfusion of gastrointestinal anastomoses intraoperatively, Surg Technol Int, 22, 27
  4. Hellan, 2014, The influence of fluorescence imaging on the location of bowel transection during robotic left-sided colorectal surgery, Surg Endosc, 28, 1695, 10.1007/s00464-013-3377-6 · DOI
  5. Jafari, 2013, The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery, Surg Endosc, 27, 3003, 10.1007/s00464-013-2832-8 · DOI · Paper page
  6. Ris, 2014, Near-infrared (NIR) perfusion angiography in minimally invasive colorectal surgery, Surg Endosc, 28, 2221, 10.1007/s00464-014-3432-y · DOI · Paper page
  7. Diana, 2014, Probe-based confocal laser endomicroscopy and fluorescence-based enhanced reality for real-time assessment of intestinal microcirculation in a porcine model of sigmoid ischemia, Surg Endosc, 28, 3224, 10.1007/s00464-014-3595-6 · DOI
  8. Diana, 2014, Real-time navigation by fluorescence-based enhanced reality for precise estimation of future anastomotic site in digestive surgery, Surg Endosc, 28, 3108, 10.1007/s00464-014-3592-9 · DOI
  9. Nair, 1974, Role of proteolytic enzyme in the prevention of postoperative intraperitoneal adhesions, Arch Surg, 108, 849, 10.1001/archsurg.1974.01350300081019 · DOI · Paper page
  10. Noll, 2012, Local but not systemic capillary lactate is a reperfusion biomarker in experimental acute limb ischaemia, Eur J Vasc Endovasc Surg, 43, 339, 10.1016/j.ejvs.2011.12.015 · DOI
  11. Charles, 2011, Effect of postconditioning on mitochondrial dysfunction in experimental aortic cross-clamping, Br J Surg, 98, 511, 10.1002/bjs.7384 · DOI · Paper page
  12. Thaveau, 2007, Ischemic preconditioning specifically restores complexes I and II activities of the mitochondrial respiratory chain in ischemic skeletal muscle, J Vasc Surg, 46, 541, 10.1016/j.jvs.2007.04.075 · DOI
  13. Selka, 2014, Fluorescence-based enhanced reality for colorectal endoscopic surgery, Biomedical Image Registration, 8545, 114, 10.1007/978-3-319-08554-8_12 · DOI

Cited by

See all 130

Metadata

Authors
Diana, M., Agnus, V, Halvax, P., Liu, Y. Y., Dallemagne, B., Schlagowski, A. I., Geny, B., Diemunsch, P., Lindner, V, & Marescaux, J.
Venue
British Journal of Surgery
Published
2015-01
Volume
102
Issue
2
Pages
e169-e176
ISSN
  • 0007-1323 (ISSN-L)
  • 1365-2168
OpenAlex
W1564793325
Cited by
130
References
4
FWCI
8.62
Type
journal article
Language
en
Open access
bronze
Funders
KarlStorz Endoskope Tuttlingen, Germany

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.