The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Near-infrared (NIR) perfusion angiography in minimally invasive colorectal surgery
Open accessAbstract
BACKGROUND: Anastomotic leakage is a devastating complication of colorectal surgery. However, there is no technology indicative of in situ perfusion of a laparoscopic colorectal anastomosis. METHODS: We detail the use of near-infrared (NIR) laparoscopy (PinPoint System, NOVADAQ, Canada) in association with fluorophore [indocyanine green (ICG), 2.5 mg/ml] injection in 30 consecutive patients who underwent elective minimally invasive colorectal resection using the simultaneous appearance of the cecum or distal ileum as positive control. RESULTS: The median (range) age of the patients was 64 (40-81) years with a median (range) BMI of 26.7 (20-35.5) kg/m(2). Twenty-four patients had left-sided resections (including six low anterior resections) and six had right-sided resections. Of the total, 25 operations were cancer resections and five were for benign disease [either diverticular strictures (n = 3) or Crohn's disease (n = 2)]. A high-quality intraoperative ICG angiogram was achieved in 29/30 patients. After ICG injection, median (range) time to perfusion fluorescence was 35 (15-45) s. Median (range) added time for the technique was 5 (3-9) min. Anastomotic perfusion was documented as satisfactory in every successful case and encouraged avoidance of defunctioning stomas in three patients with low anastomoses. There were no postoperative anastomotic leaks. CONCLUSION: Perfusion angiography of colorectal anastomosis at the time of their laparoscopic construction is feasible and readily achievable with minimal added intraoperative time. Further work is required to determine optimum sensitivity and threshold levels for assessment of perfusion sufficiency, in particular with regard to anastomotic viability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dindo, D., Demartines, N., & Clavien, P.-A. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000133083.54934.ae · Cited by 31,378
Enhanced-Reality Video Fluorescence: A Real-Time Assessment of Intestinal Viability
Diana, M., Noll, E., Diemunsch, P., Dallemagne, B., Benahmed, M. A., Agnus, V., Soler, L., Barry, B., Namer, I. J., Demartines, N., et al. (2014) · Annals of Surgery · doi:10.1097/sla.0b013e31828d4ab3 · Cited by 168 · cited 1×
“Finally, analytic measures to objectively quantify signal intensity are already evolving and require investment for their development and correlation with clinically important outcomes [18].”
Background
Cited by
Indocyanine Green: Historical Context, Current Applications, and Future Considerations
Reinhart, M. B., Huntington, C. R., Blair, L. J., Heniford, B. T., & Augenstein, V. A. (2016) · Surgical Innovation · doi:10.1177/1553350615604053 · Cited by 517
Blanco-Colino, R., & Espin-Basany, E. (2018) · Techniques in Coloproctology · doi:10.1007/s10151-017-1731-8 · Cited by 344
van Manen, L., Handgraaf, H. J. M., Diana, M., Dijkstra, J., Ishizawa, T., Vahrmeijer, A. L., & Mieog, J. S. D. (2018) · Journal of Surgical Oncology · doi:10.1002/jso.25105 · Cited by 322
De Nardi, P., Elmore, U., Maggi, G., Maggiore, R., Boni, L., Cassinotti, E., Fumagalli, U., Gardani, M., De Pascale, S., Parise, P., et al. (2020) · Surgical Endoscopy · doi:10.1007/s00464-019-06730-0 · Cited by 320
Joosten, J. J., Longchamp, G., Khan, M. F., Lameris, W., van Berge Henegouwen, M. I., Bemelman, W. A., Cahill, R. A., Hompes, R., & Ris, F. (2022) · Surgical Endoscopy · doi:10.1007/s00464-022-09136-7 · Cited by 36
Self-citation
Metadata
- Authors
- Ris, F., Hompes, R., Cunningham, C., Lindsey, I., Guy, R., Jones, O., George, B., Cahill, R. A., & Mortensen, N. J.
- Venue
- Surgical Endoscopy
- Published
- 2014-02-25
- Volume
- 28
- Issue
- 7
- Pages
- 2221-2226
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W1999980972
- Cited by
- 186
- References
- 2
- FWCI
- 14.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-infrared (NIR) perfusion angiography in minimally invasive colorectal surgery. https://app.cochat.ai/papers/10.1007/s00464-014-3432-y
- The paper
- Ris, F., Hompes, R., Cunningham, C., Lindsey, I., Guy, R., Jones, O., George, B., Cahill, R. A., & Mortensen, N. J. (2014). Near-infrared (NIR) perfusion angiography in minimally invasive colorectal surgery. Surgical Endoscopy. https://doi.org/10.1007/s00464-014-3432-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.