CoChat

Stereospecific determination of cis‐ and trans‐resveratrol in rat plasma by HPLC: application to pharmacokinetic studies

Chen, Xijing, He, Hui, Wang, Guangji, Yang, Bing, Ren, Weichao, Ma, Le, Yu, Qiaoling · 2007 · Biomedical Chromatography
Cited by 91

The DOI matches its Crossref record.

Abstract

A simple, accurate, precise, specific and reproducible high‐performance liquid chromatography (HPLC) method was developed for simultaneous determination of resveratrol isomers in rat plasma. Cis‐resveratrol was made by exposure of a trans‐resveratrol solution to sunlight for 5 days followed by separation by HPLC and identification by mass spectrometry (MS). The assay procedure involved simple liquid–liquid extraction of resveratrol isomers and internal standard (IS, caffeine) from a small plasma volume directly into acetonitrile. The supernatant liquid was added an equal volume of water and injected onto a Hypersil ODS 2 C 18 column (5 µm, 4.6 × 250 mm). Mobile phase consisting of methanol and distilled water was used at a flow rate of 1.0 mL/min for the effective separation of cis‐, trans‐resveratrol and caffeine (IS). The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 303 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of cis‐, trans‐resveratrol and IS were 3.2, 4.3 and 6.1 min, respectively. The calibration curve was linear ranging from 0.066 to 6.64 and 0.134 to 13.4 µg/mL with correlation coefficients of 0.9998 and 0.9997 for trans and cis isomers, respectively. The absolute recovery of both isomers was more than 85%. The inter‐ and intra‐day precisions in the measurement of quality control (QC) samples, 0.066, 0.664 and 6.64 µg/mL of trans‐resveratrol, were in the range 2.37–6.95% relative standard deviation (RSD) and 0.77–6.97% RSD, respectively. The inter‐ and intra‐day precisions in the measurement of quality control (QC) samples, 0.134, 1.34 and 13.4 µg/mL of cis‐resveratrol, were in the range 1.93–3.72% relative standard deviation (RSD) and 1.13–6.57% RSD, respectively. Both analytes and IS were stable in the battery of stability studies and freeze–thaw cycles. Resveratrol isomers were found to be stable for a period of 30 days on storage at −20°C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described. Copyright © 2007 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bmc.747

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Chen, X., He, H., Wang, G., Yang, B., Ren, W., Ma, L., & Yu, Q.
Venue
Biomedical Chromatography
Publisher
Wiley
Published
2007-02-12
Volume
21
Issue
3
Pages
257-265
ISSN
  • 0269-3879 (ISSN-L)
  • 1099-0801
OpenAlex
W1993009149
Cited by
91
References
0
FWCI
1.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.