CoChat

A microprocessor controlled mass spectrometer for the fully automated purification and isotopic analysis of breath carbon dioxide

Schoeller, D. A., Klein, P. D. · 1979 · Biological Mass Spectrometry
Cited by 72

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Breath tests that measure the oxidative utilization of 13C labeled substrates have been shown to be clinically useful, but have failed to gain wide acceptance because of the slow and costly isotopic analysis of the breath samples. Therefore we have developed a fully automated, microprocessor controlled CO2 purification and isotopic analysis system. The breath CO2 is cryogenically purified by passage through cold traps of -94 degrees C and -196 degrees to condense water and CO2, respectively. The CO2 is intorduced into a dual inlet, peak-stepping mass spectrometer and analyzed for isotopic content by comparison with a known standard. Thirty samples can be analyzed without operator intervention. Analysis time average 14 minutes per sample, and the analysis has a precision of 0.3% which corresponds to 3 parts excess 13C per 10(6) parts CO2. The speed of analysis is comparable with scintillation counting and permits next day reporting of clinical breath test results. The precision is sufficient for clinical applications as it is less than 0.7% isotopic variation in basal breath CO2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bms.1200060809

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 72

Metadata

Authors
Schoeller, D. A., & Klein, P. D.
Venue
Biological Mass Spectrometry
Publisher
Wiley
Published
1979-08
Volume
6
Issue
8
Pages
350-355
ISSN
  • 1076-5174 (ISSN-L)
  • 0306-042X
  • 1096-9888
OpenAlex
W2032685655
Cited by
72
References
2
FWCI
2.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A microprocessor controlled mass spectrometer for the fully automated purification and isotopic analysis of breath carbon dioxide. https://app.cochat.ai/papers/10.1002/bms.1200060809
The paper
Schoeller, D. A., & Klein, P. D. (1979). A microprocessor controlled mass spectrometer for the fully automated purification and isotopic analysis of breath carbon dioxide. Biological Mass Spectrometry. https://doi.org/10.1002/bms.1200060809

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.