CoChat

Micro‐anatomy of the renal sympathetic nervous system: A human postmortem histologic study

Atherton, Daniel S., Deep, Nicholas L., Mendelsohn, Farrell O. · 2012 · Clinical Anatomy
Cited by 157

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Hypertension remains an epidemic uncontrolled with pharmacologic therapies. A novel catheter inserted into the renal artery has been shown to lower blood pressure by ablating the renal sympathetic nerves with radiofrequency energy delivered through the arterial wall. We report a histologic study describing the anatomic substrate for this technique, specifically the renal sympathetic nervous system. Histological sections from proximal, middle, and distal renal artery segments from nine renal arteries (five human autopsies) were analyzed. Nerves were manually counted and their distance from the lumen‐intima interface was measured using a micrometer. The nerves were then categorized by location into 0.5‐mm‐wid e “rings” that were arranged circumferentially around the renal artery lumen. Of all nerves detected, 1.0% was in the 0–0.5 mm ring, 48.3% were in the 0.5–1.0 mm ring, 25.6% were in the 1.0–1.5 mm ring, 15.5% were in the 1.5–2.0 mm ring, and 9.5% were in the 2.0–2.5 mm ring. Beyond 0.5 mm, the proportion of nerves tended to decrease as the distance from the lumen increased. Totally, 90.5% of all nerves in this study existed within 2.0 mm of the renal artery lumen. Additionally, the number of nerves tended to increase along the length of the artery from proximal to distal segments (proximal = 216; middle = 323; distal = 417). In conclusion, our analysis indicates that a great proportion of renal sympathetic nerves have close proximity to the lumen‐intima interface and should thus be accessible via renal artery interventional approaches such as catheter ablation. This data provides important anatomic information for the development of ablation and other type devices for renal sympathetic denervation. Clin. Anat. 25:628–633, 2012. © 2011 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ca.21280

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 157

Metadata

Authors
Atherton, D. S., Deep, N. L., & Mendelsohn, F. O.
Venue
Clinical Anatomy
Publisher
Wiley
Published
2011-10-04
Volume
25
Issue
5
Pages
628-633
ISSN
  • 0897-3806 (ISSN-L)
  • 1098-2353
OpenAlex
W2071812952
Cited by
157
References
2
FWCI
12.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.