The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Design of Gold Nanoparticle‐Based Colorimetric Biosensing Assays
Abstract
Gold nanoparticle (AuNP)‐based colorimetric biosensing assays have recently attracted considerable attention in diagnostic applications due to their simplicity and versatility. This Minireview summarizes recent advances in this field and attempts to provide general guidance on how to design such assays. The key to the AuNP‐based colorimetric sensing platform is the control of colloidal AuNP dispersion and aggregation stages by using biological processes (or analytes) of interest. The ability to balance interparticle attractive and repulsive forces, which determine whether AuNPs are stabilized or aggregated and, consequently, the color of the solution, is central in the design of such systems. AuNP aggregation in these assays can be induced by an “interparticle‐crosslinking” mechanism in which the enthalpic benefits of interparticle bonding formation overcome interparticle repulsive forces. Alternatively, AuNP aggregation can be guided by the controlled loss of colloidal stability in a “noncrosslinking‐aggregation” mechanism. In this case, as a consequence of changes in surface properties, the van der Waals attractive forces overcome interparticle repulsive forces. Using representative examples we illustrate the general strategies that are commonly used to control AuNP aggregation and dispersion in AuNP‐based colorimetric assays. Understanding the factors that play important roles in such systems will not only provide guidance in designing AuNP‐based colorimetric assays, but also facilitate research that exploits these principles in such areas as nanoassembly, biosciences and colloid and polymer sciences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beiträge zur Optik trüber Medien, speziell kolloidaler Metallösungen
Mie, G. (1908) · Annalen der Physik · doi:10.1002/andp.19083300302 · Cited by 11,537
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Cited by
Wu, X., Song, Y., Yan, X., Zhu, C., Ma, Y., Du, D., & Lin, Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.010 · Cited by 328
Stress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Chen, T., Hu, Y., Cen, Y., Chu, X., & Lu, Y. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4035939 · Cited by 308
Miranda, B., Rea, I., Dardano, P., De Stefano, L., & Forestiere, C. (2021) · Biosensors · doi:10.3390/bios11040107 · Cited by 63
Metadata
- Authors
- Zhao, W., Brook, M. A., & Li, Y.
- Venue
- ChemBioChem
- Publisher
- Wiley
- Published
- 2008-10-06
- Volume
- 9
- Issue
- 15
- Pages
- 2363-2371
- ISSN
- 1439-4227 (ISSN-L)
- 1439-7633
- OpenAlex
- W1998651976
- Cited by
- 768
- References
- 2
- FWCI
- 15.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of Gold Nanoparticle‐Based Colorimetric Biosensing Assays. https://app.cochat.ai/papers/10.1002/cbic.200800282
- The paper
- Zhao, W., Brook, M. A., & Li, Y. (2008). Design of Gold Nanoparticle‐Based Colorimetric Biosensing Assays. ChemBioChem. https://doi.org/10.1002/cbic.200800282
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.