Nondestructive, Histologically Compatible Tissue Imaging by Desorption Electrospray Ionization Mass Spectrometry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Maintaining your integrity: Morphologically friendly DESI-MS imaging of tissue can be performed prior to histochemical and immuno-histochemical analysis on same tissue section by using new solvent systems. This novel DESI-MS imaging capability allows chemical information to be obtained while preserving tissue integrity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MALDI imaging mass spectrometry of human tissue: method challenges and clinical perspectives
Seeley, E. H., & Caprioli, R. M. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.12.002 · Cited by 197
Cited by
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Self-citationMass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Classifying Human Brain Tumors by Lipid Imaging with Mass Spectrometry
Eberlin, L. S., Norton, I., Dill, A. L., Golby, A. J., Ligon, K. L., Santagata, S., Cooks, R. G., & Agar, N. Y. R. (2012) · Cancer Research · doi:10.1158/0008-5472.can-11-2465 · Cited by 294
Self-citationIntraoperative mass spectrometry mapping of an onco-metabolite to guide brain tumor surgery
Santagata, S., Eberlin, L. S., Norton, I., Calligaris, D., Feldman, D. R., Ide, J. L., Liu, X., Wiley, J. S., Vestal, M. L., Ramkissoon, S. H., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1404724111 · Cited by 258
Self-citationShroff, E. H., Eberlin, L. S., Dang, V. M., Gouw, A. M., Gabay, M., Adam, S. J., Bellovin, D. I., Tran, P. T., Philbrick, W. M., Garcia-Ocana, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1507228112 · Cited by 255
“Note that, by using DMF:ACN as the solvent system, the tissue morphology was preserved in the stained tissue sections after the DESI-MSI process (34).”
MethodSelf-citationMolecular assessment of surgical-resection margins of gastric cancer by mass-spectrometric imaging
Eberlin, L. S., Tibshirani, R. J., Zhang, J., Longacre, T. A., Berry, G. J., Bingham, D. B., Norton, J. A., Zare, R. N., & Poultsides, G. A. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1400274111 · Cited by 225
“The histologically compatible solvent system dimethylformamide:acetonitrile (DMF:ACN) 1:1 (vol/vol) was used for analysis (20), at a flow rate of 0.”
MethodSelf-citationBanerjee, S., Zare, R. N., Tibshirani, R. J., Kunder, C. A., Nolley, R., Fan, R., Brooks, J. D., & Sonn, G. A. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1700677114 · Cited by 211
“DESI-MSI was performed in the negative ion mode (−5 kV) from m/z 50–1,000 with a spatial resolution of 200 μm (spray spot diameter) using a histologically compatible solvent system 1:1 (vol/vol) dimethylformamide/acetonitrile (DMF/ACN) (43) at a flow rate of 0.”
MethodInfluentialPirro, V., Alfaro, C. M., Jarmusch, A. K., Hattab, E. M., Cohen-Gadol, A. A., & Cooks, R. G. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1706459114 · Cited by 194
“DESI-MS was performed using dimethylformamide-acetonitrile (1:1 vol/vol), a solvent that preserves tissue morphology (26).”
MethodSelf-citationQuantitative Mass Spectrometry Imaging of Biological Systems
Unsihuay, D., Mesa Sanchez, D., & Laskin, J. (2021) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-061020-053416 · Cited by 189
“In DESI experiments, dimethylformamide has been used to preserve the morphological structure of tissue sections (47).”
MethodAmbient Ionization Mass Spectrometry for Cancer Diagnosis and Surgical Margin Evaluation
Ifa, D. R., & Eberlin, L. S. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2014.237172 · Cited by 177
Self-citationContrast Agent Mass Spectrometry Imaging Reveals Tumor Heterogeneity
Tata, A., Zheng, J., Ginsberg, H. J., Jaffray, D. A., Ifa, D. R., & Zarrine-Afsar, A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01992 · Cited by 34
Self-citationExploiting metabolic vulnerabilities after anti-VEGF antibody therapy in ovarian cancer
Glassman, D., Kim, M. S., Spradlin, M., Badal, S., Taki, M., Bhattacharya, P., Dutta, P., Kingsley, C. V., Foster, K. I., Animasahun, O., et al. (2023) · iScience · doi:10.1016/j.isci.2023.106020 · Cited by 15
Self-citation
Metadata
- Authors
- Eberlin, L. S., Ferreira, C. R., Dill, A. L., Ifa, D. R., Cheng, L., & Cooks, R. G.
- Venue
- ChemBioChem
- Publisher
- Wiley
- Published
- 2011-07-26
- Volume
- 12
- Issue
- 14
- Pages
- 2129-2132
- ISSN
- 1439-4227 (ISSN-L)
- 1439-7633
- OpenAlex
- W2073441760
- Cited by
- 150
- References
- 1
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.