Aspirin alone antiplatelet regimen after intracoronary placement of the Carbostent™: The Antares study
The DOI matches its Crossref record.
Abstract
The effect of stent coatings in preventing early thrombotic occlusion remains to be proved. The purpose of this study was to evaluate the safety and efficacy of the Carbostent™, a new coronary stent with a nonthrombogenic coating (Carbofilm™), in 110 consecutive patients (73.6% men, mean age 61 ± 9 years) who met prespecified clinical and angiographic inclusion criteria and were treated with aspirin monotherapy after stenting. Stable angina (75.5%), unstable angina (18.2%), and silent ischemia (6.3%) were clinical indications for coronary revascularization. Patients received 10,000 U of heparin and no IIb/IIIa inhibitors or postprocedural heparin. Complex lesion characteristics (B2, C) were present in 39 out of 129 (30.2%) lesions. Mean lesion length was 15.6 ± 7.4 mm, and 32% of the lesions were >15 mm (range 16–52 mm). Small coronary vessels (<3.0 mm) were treated in 28% of the cases. A total of 165 Carbostent™ were used in 129 coronary lesions of the 110 patients. Single‐vessel stenting was performed in 97 (88%) patients and multivessel stent placement in 13 (12%) patients. The mean length of the stented segment was 21 ± 13 mm (range 9–95 mm). Procedural and clinical success was achieved in all patients. At 1‐month follow‐up, there were no stent thrombosis or other major adverse cardiac events. We observed 2 (1.8%) non‐Q‐wave myocardial infarctions and 2 (1.8%) vascular complications. This study indicates that the Carbostent™ may prevent stent thrombosis in selected patients treated with aspirin only. A randomized study comparing aspirin alone versus combined ticlopidine and aspirin after Carbostent™ implantation will be needed to confirm these results. Cathet Cardiovasc Intervent 2002;55:150–156. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical applications of diamond‐like carbon coatings: A review
Roy, R. K., & Lee, K. (2007) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30768 · Cited by 496
Wilson, S. H., Fasseas, P., Orford, J. L., Lennon, R. J., Horlocker, T., Charnoff, N. E., Melby, S., & Berger, P. B. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00622-3 · Cited by 460
Kidane, A. G., Salacinski, H., Tiwari, A., Bruckdorfer, K. R., & Seifalian, A. M. (2004) · Biomacromolecules · doi:10.1021/bm0344553 · Cited by 166
Novel thromboresistant materials
Jordan, S. W., & Chaikof, E. L. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.02.048 · Cited by 153
Metadata
- Authors
- Bartorelli, A. L., Trabattoni, D., Montorsi, P., Fabbiocchi, F., Galli, S., Ravagnani, P., Grancini, L., Cozzi, S., & Loaldi, A.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2002-01-25
- Volume
- 55
- Issue
- 2
- Pages
- 150-156
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W1992989545
- Cited by
- 42
- References
- 0
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.