The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Percutaneous radial artery approach for coronary angiography
Abstract
Percutaneous entry into the distal radial artery and selective coronarography using a French 5 sheath and preshaded catheters were attempted in 100 patients with a normal Allen test. Cannulation of the radial artery was not possible in ten patients, and selective catheterization of the coronary arteries was unsuccessful in two. Manipulation of catheters presented no problem, and arterial spasm was rarely observed, only before the use of a 23‐cm‐long sheath. Only two complications without symptoms were observed: arterial dissection of the brachial artery in one patient and occlusion of the radial artery in another. With experience, this approach may become as effective and possibly safer than the transbrachial entry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hessel, S. J., Adams, D. F., & Abrams, H. L. (1981) · Radiology · doi:10.1148/radiology.138.2.7455105 · Cited by 640
On the Safety of Radial Artery Cannulation
Slogoff, S., Keats, A. S., & Arlund, C. (1983) · Anesthesiology · doi:10.1097/00000542-198307000-00008 · Cited by 355
Long-term radial artery cannulation
Bedford, R. F. (1978) · Critical Care Medicine · doi:10.1097/00003246-197801000-00016 · Cited by 79
Cited by
Radial versus femoral approach for percutaneous coronary diagnostic and interventional procedures
Agostoni, P., Biondi-Zoccai, G. G. L., De Benedictis, M. L., Rigattieri, S., Turri, M., Anselmi, M., Vassanelli, C., Zardini, P., Louvard, Y., & Hamon, M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.034 · Cited by 993
Kiemeneij, F., Laarman, G. J., Odekerken, D., Slagboom, T., & van der Wieken, R. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00064-8 · Cited by 957
Saito, S., Ikei, H., Hosokawa, G., & Tanaka, S. (1999) · Catheterization and Cardiovascular Interventions · doi:10.1002/(sici)1522-726x(199902)46:2<173::aid-ccd12>3.0.co;2-4 · Cited by 484
Hamon, M., Pristipino, C., Di Mario, C., Nolan, J., Ludwig, J., Tubaro, M., Sabate, M., Mauri-Ferré, J., Huber, K., Niemelä, K., et al. (2013) · EuroIntervention · doi:10.4244/eijv8i11a192 · Cited by 417
Barbeau, G. R., Arsenault, F., Dugas, L., Simard, S., & Larivière, M. M. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.10.038 · Cited by 414
Metadata
- Authors
- Campeau, L.
- Venue
- Catheterization and Cardiovascular Diagnosis
- Publisher
- Wiley
- Published
- 1989-01
- Volume
- 16
- Issue
- 1
- Pages
- 3-7
- ISSN
- 0098-6569 (ISSN-L)
- 1097-0304
- OpenAlex
- W2092685454
- Cited by
- 892
- References
- 3
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.