The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby
Abstract
Stent implantation in the youngest patients with a congenital heart disease implicates limitations concerning further vessel growth, the need of staged redilation, and later surgical removal. The search to overcome these restrictions led to open stent designs, with a wide adaptability to the vessel growth and recently to the development of bioabsorbable stent materials. A preterm baby born at 26 weeks of gestation was referred to our clinic following inadvertent ligation of the left pulmonary artery. Despite efficient debanding, the left lung perfusion was absent. Implantation of a biodegradable 3 mm magnesium stent was performed in a hybrid procedure when the baby weighed 1.7 kg. Reperfusion of the left lung was established and persisted throughout the 4-month follow-up period during which the gradual degradation process of the stent completed. Additional interventions, should they become necessary, seem not to be limited. Despite the small size of the baby, the degradation process was clinically well tolerated. The mechanical and degradation characteristics of the magnesium stent proved to be adequate to secure reperfusion of the previously occluded left pulmonary artery. Bioabsorbable stents with different diameters may help develop new strategies in the therapy of vessel stenosis in pediatric patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Drug‐Eluting Bioabsorbable Magnesium Stent
DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., et al. (2004) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2004.04081.x · Cited by 428
Implantation and intermediate-term follow-up of stents in congenital heart disease.
OʼLaughlin, M. P., Slack, M. C., Grifka, R. G., Perry, S. B., Lock, J. E., & Mullins, C. E. (1993) · Circulation · doi:10.1161/01.cir.88.2.605 · Cited by 331
Peeters, P., Bosiers, M., Verbist, J., Deloose, K., & Heublein, B. (2005) · Journal of Endovascular Therapy · doi:10.1583/04-1349r.1 · Cited by 275
Outcome of cardiac surgery in low birth weight and premature infants*1
Oppido, G., Napoleone, C. P., Formigari, R., Gabbieri, D., Pacini, D., Frascaroli, G., & Gargiulo, G. (2004) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2004.04.004 · Cited by 100
Ewert, P., Riesenkampff, E., NEUSS, M. B., Kretschmar, O., Nagdyman, N., & Lange, P. (2004) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20136 · Cited by 48
Cited by
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Metadata
- Authors
- Zartner, P., Cesnjevar, R., Singer, H., & Weyand, M.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2005
- Volume
- 66
- Issue
- 4
- Pages
- 590-594
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W2053996514
- Cited by
- 347
- References
- 6
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.