The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
Abstract
OBJECTIVE: We aimed to determine the safety and efficacy of biobasorbable magnesium alloy stents in porcine coronary arteries. Bioabsorbable magnesium stents carry the potential to overcome the limitations posed by permanent metallic stents such as chronic inflammation, late stent thrombosis, prolonged antiplatelet therapy, and artifacts when imaged by multislice-computed tomography or magnetic resonance imaging. METHODS: Magnesium alloy stents or stainless steel stents were randomly deployed in coronary arteries of domestic or minipigs. Domestic pigs were sacrificed at 3 days (n = 2) or 28 days, and minipigs at 3 months. RESULTS: At 3 days, magnesium alloy stents were intact, but started to show signs of degradation by 28 days. There was no evidence of stent particle embolization, thrombosis, excess inflammation, or fibrin deposition. At 28 days and 3 months, neointimal area was significantly less in magnesium alloy stent segments (2.44 +/- 0.88 mm(2) and 1.16 +/- 0.19 mm(2)) as compared with the stainless steel stent segments (5.03 +/- 1.5 mm(2) and 1.72 +/- 0.68 mm(2), P < 0.001 and 0.02). Quantitative coronary analysis indicates that percentage area stenosis and percentage diameter stenosis in magnesium alloy stent segments improved significantly at 3 months as compared to 28 days. Despite decreased neointimal hyperplasia, lumen area of the magnesium alloy stented vessels did not improve significantly. CONCLUSION: Magnesium alloy stents are safe and are associated with less neointima formation; however, reduced neointima did not result in larger lumen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Schwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Kornowski, R., Hong, M. K., Tio, F. O., Bramwell, O., Wu, H., & Leon, M. B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00450-6 · Cited by 844
Self-citationBiocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Self-citationInitial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Drug‐Eluting Bioabsorbable Magnesium Stent
DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., et al. (2004) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2004.04081.x · Cited by 428
Self-citationDrug-eluting stents: caution and concerns for long-term outcome
Virmani, R., Farb, A., Guagliumi, G., & Kolodgie, F. D. (2004) · Coronary Artery Disease · doi:10.1097/00019501-200409000-00003 · Cited by 231
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Degradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Self-citationProgress and Challenge for Magnesium Alloys as Biomaterials
Zeng, R., Dietzel, W., Witte, F., Hort, N., & Blawert, C. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200800035 · Cited by 680
Developments in metallic biodegradable stents☆
Hermawan, H., Dubé, D., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 604
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Feyerabend, F., Fischer, J., Holtz, J., Witte, F., Willumeit, R., Drücker, H., Vogt, C., & Hort, N. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.09.024 · Cited by 598
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Ding, Y., Wen, C., Hodgson, P., & Li, Y. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21746a · Cited by 531
Onuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Current status and outlook on the clinical translation of biodegradable metals
Han, H.-S., Loffredo, S., Jun, I., Edwards, J., Kim, Y.-C., Seok, H.-K., Witte, F., Mantovani, D., & Glyn-Jones, S. (2019) · Materials Today · doi:10.1016/j.mattod.2018.05.018 · Cited by 423
Haude, M., Erbel, R., Erne, P., Verheye, S., Degen, H., Böse, D., Vermeersch, P., Wijnbergen, I., Weissman, N., Prati, F., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61765-6 · Cited by 423
Self-citationYang, H., Wang, C., Liu, C., Chen, H., Wu, Y., Han, J., Jia, Z., Lin, W., Zhang, D., Li, W., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.08.022 · Cited by 399
Fe–Mn alloys for metallic biodegradable stents: Degradation and cell viability studies☆
Hermawan, H., Purnama, A., Dube, D., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.025 · Cited by 372
Robinson, D. A., Griffith, R. W., Shechtman, D., Evans, R. B., & Conzemius, M. G. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.007 · Cited by 351
Corrosion fatigue behaviors of two biomedical Mg alloys – AZ91D and WE43 – In simulated body fluid
Gu, X. N., Zhou, W. R., Zheng, Y. F., Cheng, Y., Wei, S. C., Zhong, S. P., Xi, T. F., & Chen, L. J. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.07.026 · Cited by 350
Haude, M., Ince, H., Abizaid, A., Toelg, R., Lemos, P. A., von Birgelen, C., Christiansen, E. H., Wijns, W., Neumann, F.-J., Kaiser, C., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00447-x · Cited by 349
Self-citationBornapour, M., Muja, N., Shum-Tim, D., Cerruti, M., & Pekguleryuz, M. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.07.045 · Cited by 287
Biodegradable Magnesium Alloys: A Review of Material Development and Applications
Persaud-Sharma, D., & McGoron, A. (2012) · Journal of Biomimetics, Biomaterials and Tissue Engineering · doi:10.4028/www.scientific.net/jbbte.12.25 · Cited by 287
Bioresorbable scaffolds: rationale, current status, challenges, and future
Iqbal, J., Onuma, Y., Ormiston, J., Abizaid, A., Waksman, R., & Serruys, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht542 · Cited by 269
Self-citationCurrent Status of Bioresorbable Scaffolds in the Treatment of Coronary Artery Disease
Wiebe, J., Nef, H. M., & Hamm, C. W. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.041 · Cited by 255
Surface modification of biodegradable magnesium and its alloys for biomedical applications
Tian, P., & Liu, X. (2015) · Regenerative Biomaterials · doi:10.1093/rb/rbu013 · Cited by 218
Wu, J., Jin, L., Tan, J.-Y., Chen, X.-F., Wang, Q.-Q., Yuan, G.-Y., & Chen, T.-X. (2021) · Annals of Translational Medicine · doi:10.21037/atm-21-1375 · Cited by 17
Metadata
- Authors
- Waksman, R., Pakala, R., Kuchulakanti, P. K., Baffour, R., Hellinga, D., Seabron, R., Tio, F. O., Wittchow, E., Hartwig, S., Harder, C., Rohde, R., Heublein, B., Andreae, A., Waldmann, K.-H., & Haverich, A.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2006
- Volume
- 68
- Issue
- 4
- Pages
- 607-617
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W2043023006
- Cited by
- 330
- References
- 14
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.