Abstract
Since the first description of balloon pulmonary valvuloplasty in 1982 by Kan, the procedure has been extensively utilized by several groups of workers for relief of pulmonary valve stenosis. It is generally recommended that the procedure be performed for peak‐to‐peak gradients in excess of 50 mmHg. The technique involves positioning one or more balloon catheters across the stenotic valve, usually over an extra‐stiff guide wire and inflating the balloons with diluted contrast material, thus producing valvotomy. The procedural details are described in this paper. The currently recommended balloon/annulus ratio is 1.2 to 1.25. Immediate reduction of gradient, increase in jet width and free motion of the pulmonary valve leaflets with less doming have been observed following balloon dilatation. Improvement of right ventricular function, tricuspid insufficiency and right‐to‐left shunt has also occurred. Complication can occur, but are rare and minimal. At mid‐term follow‐up, both catheterization measured peak‐to‐peak gradients and Doppler‐measured peak instantaneous gradients remain improved for the group as a whole. However, restenosis, defined as gradient ≥50 mmHg, has been observed in nearly 10% of children. Predictors of restenosis include balloon/annulus ratio <1.2 and immediate post‐valvuloplasty gradient ≥30 mmHg. Small pulmonary valve annulus, earlier study year and post‐surgical complex pulmonary stenosis have also been identified as factors predictive of restenosis. Redilatation with balloons that are larger than those used at the time of initial balloon valvuloplasty produces excellent results and redilatation is the procedure of choice in the management of restenosis after previous balloon pulmonary valvuloplasty. Long‐term follow‐up results are scanty, but the limited data reveal minimal additional restenosis, event‐free rates in mid‐80s and mid‐70s at 10 and 15 years respectively and significant increase in prevalence of pulmonary insufficiency. Balloon pulmonary valvuloplasty is equally successful in neonates as well as in adult subjects. In conclusion, balloon pulmonary valvuloplasty is the treatment of choice for relief of pulmonary valve stenosis. Use of balloons 1.2 to 1.25 times larger than pulmonary valve annulus may produce optimal results. Life‐long follow‐up to identify the significance of residual pulmonary insufficiency is indicated. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonoperative Dilatation of Coronary-Artery Stenosis: Percutaneous Transluminal Coronary Angioplasty
Grüntzig, A. R., Senning, Å., & Siegenthaler, W. E. (1979) · New England Journal of Medicine · doi:10.1056/nejm197907123010201 · Cited by 2,419
Percutaneous Balloon Valvuloplasty: A New Method for Treating Congenital Pulmonary-Valve Stenosis
Kan, J. S., White, R. I., Mitchell, S. E., & Gardner, T. J. (1982) · New England Journal of Medicine · doi:10.1056/nejm198208263070907 · Cited by 731 · cited 1×
“[5] applied the technique of Gruntzig et al.”
Rocchini, A. P., Beekman, R. H., Shachar, G. B., Benson, L., Schwartz, D., & Kan, J. S. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)91388-m · Cited by 308
Dalton, H. W. (1951) · PubMed · Cited by 272
Stanger, P., Cassidy, S. C., Girod, D. A., Kan, J. S., Lababidi, Z., & Shapiro, S. R. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)91387-l · Cited by 224 · cited 1×
“35% major complication rate [45] from the 822 balloon pulFig.”
Percutaneous balloon valvotomy of congenital pulmonary stenosis using oversized balloons
Radtke, W., Keane, J. F., Fellows, K. E., Lang, P., & Lock, J. E. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80434-x · Cited by 184 · cited 2×
“2 times the pulmonary valve annulus in effectively relieving pulmonary stenosis acutely [20] and both acutely and at follow-up [21–23] is well recognized.”
Percutaneous Balloon Valvuloplasty for Pulmonic Stenosis in Adolescents and Adults
Chen, C.-R., Cheng, T. O., Huang, T., Zhou, Y.-L., Chen, J.-Y., Huang, Y.-G., & Li, H.-J. (1996) · New England Journal of Medicine · doi:10.1056/nejm199607043350104 · Cited by 170
Percutaneous balloon valvuloplasty for pulmonic valve stenosis in the adult
Pepine, C. J., Gessner, I. H., & Feldman, R. L. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90491-x · Cited by 132 · cited 1×
“[64], several other groups of workers used this technique [16,36,65–68].”
Results of three to 10 year follow up of balloon dilatation of the pulmonary valve
Rao, P. S., Galal, O., Patnana, M., Buck, S. H., & Wilson, A. D. (1998) · Heart · doi:10.1136/hrt.80.6.591 · Cited by 120
Self-citation“Balloon valvulotomy” of congenital pulmonary valve stenosis with tricuspid valve insufficiency
Semb, B. K. H., Tjønneland, S., Stake, G., & Aabyholm, G. (1979) · CardioVascular and Interventional Radiology · doi:10.1007/bf02552069 · Cited by 107 · cited 1×
“[4] employed a balloon-tipped angiographic (Berman) catheter to produce rupture of pulmonary valve commissures by rapidly withdrawing the inflated balloon across the pulmonary valve.”
Cited by
Gellis, L., Banka, P., Marshall, A., Emani, S., & Porras, D. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25930 · Cited by 13
“BD offers the potential for relief of RVOTO with ongoing preservation of pulmonary valve competence and avoidance of free PR [10].”
Background
Metadata
- Authors
- Rao, P. S.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2007-02-28
- Volume
- 69
- Issue
- 5
- Pages
- 747-763
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W2123954477
- Cited by
- 176
- References
- 28
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.