CoChat

Preliminary effects of renal denervation with saline irrigated catheter on cardiac systolic function in patients with heart failure: A prospective, randomized, controlled, pilot study

Chen, Weijie, Ling, Zhiyu, Xu, Yanping, Liu, Zengzhang, Su, Li, Du, Huaan, Xiao, Peilin, Lan, Xianbin, Shan, Qijun, Yin, Yuehui · 2017 · Catheterization and Cardiovascular Interventions
Cited by 66

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Objective: To assess efficacy and safety of renal denervation (RDN) for heart failure (HF). Background: RDN has been demonstrated to be an effective method in lowing overactive sympathetic nerve. However, it's feasibility and efficacy for HF is unclear. Methods: In this randomized, controlled pilot study, patients with HF were randomly assigned in 1:1 ratio to undergo RDN plus optimal medical therapy (RDN group) or only optimal medical therapy (control group). Before randomization, patients received optimal medical therapy at least half a year. Primary efficacy end point was the change in LVEF over six months; secondary efficacy end points were the change in six‐minute walk distance and SF‐36 Health Survey scores over six months. Results: Up to Apr 2015, sixty symptomatic HF patients were successfully enrolled into study. Thirty patients were randomly assigned to RDN group and 30 patients were randomly assigned to control group. All patients completed six months follow up. During follow up, no severe adverse events were observed. Blood pressure was stable in both groups. Patients in RDN group had shown a significant improvement in LVEF (P < 0.001), SMWD (P = 0.043), NYHA class (P < 0.001), NT‐proBNP (P < 0.001) and office heart rate (P = 0.008). Compared with control group, RDN patients were associated with significant improvement in all domains of SF‐36 but bodily pain (P = 0.74). No significant change in estimate glomerular filtration nor complication of renal artery stenosis were observed. Conclusions: Results imply that RDN could be safely applied to treatment of HF and probably improve cardiac systolic function and patients' quality of life. © 2016 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ccd.26475

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 66

Metadata

Authors
Chen, W., Ling, Z., Xu, Y., Liu, Z., Su, L., Du, H., Xiao, P., Lan, X., Shan, Q., & Yin, Y.
Venue
Catheterization and Cardiovascular Interventions
Publisher
Wiley
Published
2016-05-03
Volume
89
Issue
4
Pages
E153-E161
ISSN
  • 1522-1946 (ISSN-L)
  • 1522-726X
OpenAlex
W2607353521
Cited by
66
References
5
FWCI
4.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preliminary effects of renal denervation with saline irrigated catheter on cardiac systolic function in patients with heart failure: A prospective, randomized, controlled, pilot study. https://app.cochat.ai/papers/10.1002/ccd.26475
The paper
Chen, W., Ling, Z., Xu, Y., Liu, Z., Su, L., Du, H., Xiao, P., Lan, X., Shan, Q., & Yin, Y. (2017). Preliminary effects of renal denervation with saline irrigated catheter on cardiac systolic function in patients with heart failure: A prospective, randomized, controlled, pilot study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.26475

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.