Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients ≥700 grams

Open access
Sathanandam, Shyam K., Gutfinger, Dan, O'Brien, Laura, Forbes, Thomas J., Gillespie, Matthew J., Berman, Darren P., Armstrong, Aimee K., Shahanavaz, Shabana, Jones, Thomas K., Morray, Brian H., Rockefeller, Toby A., Justino, Henri, Nykanen, David G., Zahn, Evan M. · 2020 · Catheterization and Cardiovascular Interventions
Cited by 161

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Objectives: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure. Background: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature. Methods: This was a single arm, prospective, multicenter, non‐randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6‐month follow‐up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow‐up. Results: The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g. Conclusions: This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ccd.28973

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Sathanandam, S. K., Gutfinger, D., O'Brien, L., Forbes, T. J., Gillespie, M. J., Berman, D. P., Armstrong, A. K., Shahanavaz, S., Jones, T. K., Morray, B. H., Rockefeller, T. A., Justino, H., Nykanen, D. G., & Zahn, E. M.
Venue
Catheterization and Cardiovascular Interventions
Publisher
Wiley
Published
2020-05-20
Volume
96
Issue
6
Pages
1266-1276
ISSN
  • 1522-1946 (ISSN-L)
  • 1522-726X
OpenAlex
W3027665709
Cited by
161
References
9
FWCI
9.75
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›