Instant Detection of Cerebral Blood Flow Changes in Infants with Congenital Heart Disease during Transcatheter Interventions
Open accessAbstract
Background: Transcatheter interventions are increasingly used in children with congenital heart disease. However, these interventions can affect cardiac output and cerebral circulation. In this pilot study, we aimed to investigate the use of NeoDoppler, a continuous transfontanellar cerebral Doppler monitoring system, to evaluate the impact of transcatheter interventions on cerebral circulation. Methods: Nineteen participants under one year of age (mean age 3.5 months) undergoing transcatheter cardiac interventions were prospectively included. Transfontanellar cerebral Doppler monitoring with the NeoDoppler system was initiated after intubation and continued until the end of the procedure. Results: Instant detection of changes in cerebral blood flow were observed across a spectrum of transcatheter interventions. Balloon aortic valvuloplasty demonstrated temporary cessation of cerebral blood flow during balloon inflation. Increase in cerebral diastolic blood flow velocity and decreased pulsatility were observed during patent ductus arteriosus occlusion. Changes in cerebral blood flow patterns were detected in two patients who encountered complications during their transcatheter interventions. There was no significant change in Doppler parameters before and after the interventions for the entire patient group. High quality recordings were achieved in 87.3% of the monitoring period. Conclusions: Continuous transfontanellar cerebral Doppler is feasible in monitoring cerebral hemodynamic trends and shows instantaneous changes associated with interventions and complications. It could become a useful monitoring tool during transcatheter interventions in infants.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The authors concluded that NeoDoppler may aid both anesthesiologists and interventional cardiologists by identifying early signs of neurologic or hemodynamic instability.
“The authors concluded that NeoDoppler may aid both anesthesiologists and interventional cardiologists by identifying early signs of neurologic or hemodynamic instability.”
From Trends and Challenges in Noninvasive Hemodynamic Monitoring of Neonates Following Cardiac Surgery: A Narrative Review (2025) · cites this paper as [63]
The Conclusions say the monitoring could be useful to interventionists and anesthesiologists and can display immediate changes associated with hemodynamically significant interventions or complications. Discussion §4.2 likewise describes immediate Doppler changes during complications. The paper does not establish that these changes identify early signs of neurologic instability; §4.4 notes the lack of neurocognitive follow-up or cerebral MRI. (LLM, conf=0.82)
Experimental — accuracy not yet measuredIn a small, single-center study by Olsen et al., NeoDoppler was found to be a potentially valuable tool for real-time cerebral monitoring during transcatheter interventions in infants with CHD.
“In a small, single-center study by Olsen et al., this technology was found to be a potentially valuable tool for real-time cerebral monitoring during transcatheter interventions in infants with CHD [63].”
From Trends and Challenges in Noninvasive Hemodynamic Monitoring of Neonates Following Cardiac Surgery: A Narrative Review (2025) · cites this paper as [63]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Sathanandam, S. K., Gutfinger, D. E., O'Brien, L., et al. (2020) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.28973 · Cited by 168 · see citing works
El-Said, H. G., Bratincsák, A., Foerster, S. R., et al. (2013) · Journal of the American Heart Association · doi:10.1161/jaha.113.000424 · Cited by 92 · see citing works
Near-Infrared Spectroscopy in Pediatric Congenital Heart Disease
Zaleski, K. L., & Kussman, B. D. (2019) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2019.08.048 · Cited by 85 · see citing works
Mitra, S., de Boode, W. P., Weisz, D. E., & Shah, P. S. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013588.pub2 · Cited by 83 · see citing works
eurUS.brain group, Camfferman, F. A., de Goederen, R., et al. (2020) · Pediatric Research · doi:10.1038/s41390-020-0777-x · Cited by 58 · see citing works
Long-Term Outcomes of Balloon Valvuloplasty for Isolated Pulmonary Valve Stenosis
Devanagondi, R., Peck, D., Sagi, J., et al. (2016) · Pediatric Cardiology · doi:10.1007/s00246-016-1506-4 · Cited by 57 · see citing works
Long-Term Outcome After Transcatheter Closure of Atrial Septal Defect in Older Patients
Takaya, Y., Akagi, T., Kijima, Y., Nakagawa, K., Sano, S., & Ito, H. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.02.002 · Cited by 56 · see citing works
NeoDoppler: New ultrasound technology for continuous cerebral circulation monitoring in neonates
Vik, S. D., Torp, H. G., Follestad, T., Støen, R. Ø., & Nyrnes, S. A. (2019) · Pediatric Research · doi:10.1038/s41390-019-0535-0 · Cited by 38 · see citing works
Self-citationBissonnette, B., & Benson, L. N. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03012902 · Cited by 32 · see citing works
Current Status and Future Potential of Transcatheter Interventions in Congenital Heart Disease
Kenny, D. P., & Hijazi, Z. M. (2017) · Circulation Research · doi:10.1161/circresaha.116.309185 · Cited by 30 · see citing works
Saliba, É., Chantepie, A., Gold, F., et al. (1991) · European Journal of Pediatrics · doi:10.1007/bf01955941 · Cited by 25 · see citing works
Cerebral and Splanchnic Hemodynamics after Duct Ligation in Very Low Birth Weight Infants
Hoodbhoy, S., Cutting, H. A., Seddon, J. A., et al. (2008) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2008.07.051 · Cited by 23 · see citing works
van der Laan, M. E., Verhagen, E. A., Bos, A. F., Berger, R. M. F., & Kooi, E. M. W. (2012) · Pediatric Research · doi:10.1038/pr.2012.147 · Cited by 21 · see citing works
Moerman, A., Meert, F., & Hert, S. G. D. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9791-7 · Cited by 18 · see citing works
Transcatheter Cardiac Interventions in the Newborn
Barry, O. M., Bouhout, I., Turner, M. E., Petit, C. J., & Kalfa, D. M. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.03.374 · Cited by 16 · see citing works
Near Infrared Spectroscopy Monitoring in the Pediatric Cardiac Catheterization Laboratory
Tanıdır, İ. C., Öztürk, E., Özyılmaz, İ., et al. (2014) · Artificial Organs · doi:10.1111/aor.12256 · Cited by 14 · see citing works
Keusters, L., Purna, J., Deshpande, P., et al. (2020) · Journal of Perinatology · doi:10.1038/s41372-020-0663-8 · Cited by 13 · see citing works
Continuous monitoring of cerebral blood flow during general anaesthesia in infants
Vik, S. D., Torp, H. G., Jarmund, A. H., Kiss, G. H., Follestad, T., Støen, R. Ø., & Nyrnes, S. A. (2023) · BJA Open · doi:10.1016/j.bjao.2023.100144 · Cited by 13 · see citing works
Self-citationPotential Role of Transfontanelle Ultrasound for Infants Undergoing Modified Blalock-Taussig Shunt
Kim, E., Lee, J., Song, I., Kim, H., Jang, Y., Kim, W., Kwak, J. G., & Kim, J. (2017) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2017.12.017 · Cited by 12 · see citing works
Cerebral blood flow dynamics during cardiac surgery in infants
Leth-Olsen, M., Døhlen, G., Torp, H., & Nyrnes, S. A. (2025) · Pediatric Research · doi:10.1038/s41390-024-03161-z · Cited by 12 · see citing works
Self-citationRodriguez, R. A., Hosking, M., Duncan, W. J., et al. (1998) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/(sici)1097-0304(199803)43:3 · Cited by 11 · see citing works
Leth-Olsen, M., Døhlen, G., Torp, H. G., & Nyrnes, S. A. (2022) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2022.02.021 · Cited by 11 · see citing works
Self-citationNeurophysiological Effects of Pediatric Balloon Dilatation Procedures
de Vries, J. W., Hoorntje, T. M., & Sreeram, N. (2000) · Pediatric Cardiology · doi:10.1007/s002460010110 · Cited by 9 · see citing works
Mir, M., Moore, S. S., Wutthigate, P., Simoneau, J., Martinez, D. V., Shemie, S. D., Brossard‐Racine, M., Dancea, A., Bertolizio, G., & Altit, G. (2023) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2023.02.015 · Cited by 9 · see citing works
Cerebral Blood Flow Velocity During Occlusive Manipulation of Patent Ductus Arteriosus in Children
Rodriguez, R. A., Cornel, G., Hosking, M., et al. (1999) · Journal of Neuroimaging · doi:10.1111/jon19999123 · Cited by 8 · see citing works
Transcatheter Interventions for Neonates with Congenital Heart Disease: A Review
Meliota, G., & Vairo, U. (2023) · Diagnostics · doi:10.3390/diagnostics13162673 · Cited by 6 · see citing works
Ing, R. J., & Twite, M. D. (2018) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2018.01.034 · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Nedelcu, C., Ionescu, N. S., Bizubac, A. M., Filip, C., & Cirstoveanu, C. (2025) · Life · doi:10.3390/life15101621 · Cited by 2 · see citing works
“In a small, single-center study by Olsen et al., this technology was found to be a potentially valuable tool for real-time cerebral monitoring during transcatheter interventions in infants with CHD [63].”
- Authors
- Leth-Olsen, M., Døhlen, G., Torp, H., & Nyrnes, S. A.
- Affiliations
- Norwegian University of Science and Technology (NO)
- Oslo University Hospital (NO)
- Corresponding author
- Leth-Olsen, Martin
- Venue
- Journal of Clinical Medicine
- Publisher
- MDPI AG
- Published
- 2024-05-26
- Volume
- 13
- Issue
- 11
- Pages
- 3115
- ISSN
- 2077-0383 (ISSN-L)
- PMC
- PMC11172647
- OpenAlex
- W4399055059
- Cited by
- 1
- References
- 27
- Citations by year
- 2025: 1
- FWCI
- 0.31
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Clinical Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, cc-by)
- Funders
- Research Council of Norway (260699/O30, 2017/38297, 2018/42794, 2018/115, 8/18)
- Liaison Committee for education, research, and innovation in Central Norway (260699/O30, 2017/38297, 2018/42794, 2018/115, 8/18)
- Norwegian Association for Children with Congenital Heart Disease’s Research Foundation (260699/O30, 2017/38297, 2018/42794, 2018/115, 8/18)
- Heart Foundation, St Olav’s University Hospital’s gift foundation (260699/O30, 2017/38297, 2018/42794, 2018/115, 8/18)
- Topics
- Health Sciences › Medicine › Epidemiology › Congenital Heart Disease Studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiovascular Conditions and Treatments
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cardiovascular and Diving-Related Complications
- Keywords
- cerebral blood flow, congenital heart disease, infants, transcatheter interventions, balloon aortic valvuloplasty, cerebral hemodynamics, procedural complications, cardiac output
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review