The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Electrochemical Impedance Spectroscopy Based Biosensors: Mechanistic Principles, Analytical Examples and Challenges towards Commercialization for Assays of Protein Cancer Biomarkers
Open accessAbstract
Impedimetric affinity biosensors are, without any doubt, among the most sensitive analytical devices available, offering low limits of detection and wide linear response ranges. There are, however, only a few papers detailing the application of impedimetric biosensors for the analysis of clinically relevant samples with due clinical performance. The fact that these devices have not found their way to any commercial or clinical use to date might be surprising, since an electrochemical assay platform based on portable potentiostats is a success story for monitoring a range of clinical parameters such as ions, haematological indicators and glucose. This review discusses the reasons behind this discrepancy and addresses the barriers to be overcome in order to achieve the point‐of‐care diagnostics using such devices for detection of protein oncomarkers approved by FDA. The final part of the review covers the most recent progress in the area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Detection and localization of surgically resectable cancers with a multi-analyte blood test
Cohen, J. D., Li, L., Wang, Y., Thoburn, C., Afsari, B., Danilova, L., Douville, C., Javed, A. A., Wong, F., Mattox, A., et al. (2018) · Science · doi:10.1126/science.aar3247 · Cited by 2,783
Affibody molecules as engineered protein drugs
Frejd, F. Y., & Kim, K.-T. (2017) · Experimental & Molecular Medicine · doi:10.1038/emm.2017.35 · Cited by 225
Cited by
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications
Magar, H. S., Hassan, R. Y. A., & Mulchandani, A. (2021) · Sensors · doi:10.3390/s21196578 · Cited by 1,335
Impedance Analysis of Electrochemical Systems
Vivier, V., & Orazem, M. E. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00876 · Cited by 615
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
Metadata
- Authors
- Bertok, T., Lorencova, L., Chocholova, E., Jane, E., Vikartovska, A., Kasak, P., & Tkac, J.
- Venue
- ChemElectroChem
- Publisher
- Wiley
- Published
- 2018-09-21
- Volume
- 6
- Issue
- 4
- Pages
- 989-1003
- ISSN
- 2196-0216 (ISSN-L)
- OpenAlex
- W2888831785
- Cited by
- 180
- References
- 3
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Impedance Spectroscopy Based Biosensors: Mechanistic Principles, Analytical Examples and Challenges towards Commercialization for Assays of Protein Cancer Biomarkers. https://app.cochat.ai/papers/10.1002/celc.201800848
- The paper
- Bertok, T., Lorencova, L., Chocholova, E., Jane, E., Vikartovska, A., Kasak, P., & Tkac, J. (2019). Electrochemical Impedance Spectroscopy Based Biosensors: Mechanistic Principles, Analytical Examples and Challenges towards Commercialization for Assays of Protein Cancer Biomarkers. ChemElectroChem. https://doi.org/10.1002/celc.201800848
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.