The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications
Open accessAbstract
Electrochemical impedance spectroscopy (EIS) is a powerful technique used for the analysis of interfacial properties related to bio-recognition events occurring at the electrode surface, such as antibody–antigen recognition, substrate–enzyme interaction, or whole cell capturing. Thus, EIS could be exploited in several important biomedical diagnosis and environmental applications. However, the EIS is one of the most complex electrochemical methods, therefore, this review introduced the basic concepts and the theoretical background of the impedimetric technique along with the state of the art of the impedimetric biosensors and the impact of nanomaterials on the EIS performance. The use of nanomaterials such as nanoparticles, nanotubes, nanowires, and nanocomposites provided catalytic activity, enhanced sensing elements immobilization, promoted faster electron transfer, and increased reliability and accuracy of the reported EIS sensors. Thus, the EIS was used for the effective quantitative and qualitative detections of pathogens, DNA, cancer-associated biomarkers, etc. Through this review article, intensive literature review is provided to highlight the impact of nanomaterials on enhancing the analytical features of impedimetric biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The reduction of graphene oxide
Pei, S., & Cheng, H.-M. (2012) · Carbon · doi:10.1016/j.carbon.2011.11.010 · Cited by 5,164
Graphene/Polymer Nanocomposites
Kim, H., Abdala, A. A., & Macosko, C. W. (2010) · Macromolecules · doi:10.1021/ma100572e · Cited by 3,406
Georgakilas, V., Perman, J. A., Tucek, J., & Zboril, R. (2015) · Chemical Reviews · doi:10.1021/cr500304f · Cited by 2,147
Synthesis of Graphene Oxide using Modified Hummers Method: Solvent Influence
Zaaba, N. I., Foo, K. L., Hashim, U., Tan, S. J., Liu, W.-W., & Voon, C. H. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.04.118 · Cited by 1,564
Electrochemical Impedance Spectroscopy and its Applications
Lasia, A. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8933-7 · Cited by 1,355
Katz, E., & Willner, I. (2003) · Electroanalysis · doi:10.1002/elan.200390114 · Cited by 1,351
Electrochemical impedance spectroscopy
Wang, S., Zhang, J., Gharbi, O., Vivier, V., Gao, M., & Orazem, M. E. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00039-w · Cited by 1,140
Gooding, J. J. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.052 · Cited by 1,060
Electrochemical Impedance Spectroscopy of Metal Oxide Electrodes for Energy Applications
Bredar, A. R. C., Chown, A. L., Burton, A. R., & Farnum, B. H. (2020) · ACS Applied Energy Materials · doi:10.1021/acsaem.9b01965 · Cited by 1,035
Review of Carbon and Graphene Quantum Dots for Sensing
Li, M., Chen, T., Gooding, J. J., & Liu, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00514 · Cited by 991
Research works printed but not linked: 46
- Ozdemir, 2013, A Label-Free Potentiometric Sensor Principle for the Detection of Antibody–Antigen Interactions, Anal. Chem., 85, 4770, 10.1021/ac400514u · doi:10.1021/ac400514u
- Page, 1944, Recent Developments in Polarographic Analysis, Nature, 154, 199, 10.1038/154199a0 · doi:10.1038/154199a0
- Chauhan, 2021, Contemporary voltammetric techniques and its application to pesticide analysis: A review, Mater. Today Proc., 37, 3231, 10.1016/j.matpr.2020.09.092 · doi:10.1016/j.matpr.2020.09.092
- Méndez-Vilas, A. (2005). Electrochemical Impedance Spectroscopy as a Tool for Electrical and Structural Characterizations of Membranes in Contact with Electrolyte Solutions. Recent Advances in Multidisciplinary Applied Physics, Elsevier Science Ltd.
- Kreysa, G., Ota, K.-i., and Savinell, R.F. (2014). Electrochemical Impedance Spectroscopy (EIS) Applications to Sensors and Diagnostics. Encyclopedia of Applied Electrochemistry, Springer. · DOI · Paper page
- Sawan, M. (2015). Impedance Spectroscopy for Biosensing: Circuits and Applications. Handbook of Biochips: Integrated Circuits and Systems for Biology and Medicine, Springer. · doi:10.1007/978-1-4614-6623-9
- Ha, 2019, Implementation of Second-Generation Fourier Transform Electrochemical Impedance Spectroscopy with Commercial Potentiostat and Application to Time-Resolved Electrochemical Impedance Spectroscopy, Anal. Chem., 91, 14208, 10.1021/acs.analchem.9b03226 · doi:10.1021/acs.analchem.9b03226
- Lasia, A. (2014). Definition of Impedance and Impedance of Electrical Circuits. Electrochemical Impedance Spectroscopy and Its Applications, Springer. · DOI · Paper page
- Sun, J., and Liu, Y. (2019). Unique Constant Phase Element Behavior of the Electrolyte-Graphene Interface. Nanomaterials, 9. · doi:10.3390/nano9070923
- Karunakaran, C., Bhargava, K., and Benjamin, R. (2015). Biosensors and Bioelectronics, Elsevier.
- Sedki, 2019, Online-monitoring of biofilm formation using nanostructured electrode surfaces, Mater. Sci. Eng. C, 100, 178, 10.1016/j.msec.2019.02.112 · doi:10.1016/j.msec.2019.02.112
- Anusha, T., Sai Bhavani, K., Shankumkha Kumar, J.V., Kumar Brahman, P., and Hassan, R.Y.A. (2021). Fabrication of electrochemical immunosensor based on GCN-β-CD/Au nanocomposite for the monitoring of vitamin D deficiency. Bioelectrochemistry, 107935. In Press. · doi:10.1016/j.bioelechem.2021.107935
- Izadi, 2019, An impedimetric aptasensor for ultrasensitive detection of Penicillin G based on the use of reduced graphene oxide and gold nanoparticles, Microchim. Acta, 186, 372, 10.1007/s00604-019-3510-x · doi:10.1007/s00604-019-3510-x
- Manickam, 2010, A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor Array, IEEE Trans. Biomed. Circuits Syst., 4, 379, 10.1109/TBCAS.2010.2081669 · doi:10.1109/tbcas.2010.2081669
- Espinosa, 2019, Iron Oxide Nanoflower–Based Screen Print Electrode for Enhancement Removal of Organic Dye Using Electrochemical Approach, Electrocatalysis, 10, 663, 10.1007/s12678-019-00554-1 · doi:10.1007/s12678-019-00554-1
- Mahmoud, 2019, Development of an impedimetric non enzymatic sensor based on ZnO and Cu doped ZnO nanoparticles for the detection of glucose, J. Alloy. Compd., 786, 960, 10.1016/j.jallcom.2019.02.060 · doi:10.1016/j.jallcom.2019.02.060
- Ghica, 2019, Impedimetric sensor for tyramine based on gold nanoparticle doped-poly(8-anilino-1-naphthalene sulphonic acid) modified gold electrodes, Talanta, 195, 604, 10.1016/j.talanta.2018.11.054 · doi:10.1016/j.talanta.2018.11.054
- Gao, 2011, Highly sensitive impedimetric sensing of DNA hybridization based on the target DNA-induced displacement of gold nanoparticles attached to ssDNA probe, Electrochem. Commun., 13, 335, 10.1016/j.elecom.2011.01.018 · doi:10.1016/j.elecom.2011.01.018
- Jolly, 2017, Self-assembled gold nanoparticles for impedimetric and amperometric detection of a prostate cancer biomarker, Sens. Actuators B Chem., 251, 637, 10.1016/j.snb.2017.05.040 · doi:10.1016/j.snb.2017.05.040
- Yeter, 2021, An electrochemical label-free DNA impedimetric sensor with AuNP-modified glass fiber/carbonaceous electrode for the detection of HIV-1 DNA, Chem. Pap., 75, 77, 10.1007/s11696-020-01280-5 · doi:10.1007/s11696-020-01280-5
- Lin, 2019, An impedimetric biosensor for E. coli O157:H7 based on the use of self-assembled gold nanoparticles and protein G, Microchim. Acta, 186, 169, 10.1007/s00604-019-3282-3 · doi:10.1007/s00604-019-3282-3
- Elshafey, 2013, Electrochemical impedance immunosensor based on gold nanoparticles–protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue, Biosens. Bioelectron., 50, 143, 10.1016/j.bios.2013.05.063 · doi:10.1016/j.bios.2013.05.063
- Filip, 2015, Graphene as a signal amplifier for preparation of ultrasensitive electrochemical biosensors, Chem Zvesti, 69, 112
- Llorente, 2019, Electrochemical reduction of graphene oxide on biomedical grade CoCr alloy, Appl. Surf. Sci., 465, 1028, 10.1016/j.apsusc.2018.09.188 · doi:10.1016/j.apsusc.2018.09.188
- Takemura, 2020, Electrochemical detection of white spot syndrome virus with a silicone rubber disposable electrode composed of graphene quantum dots and gold nanoparticle-embedded polyaniline nanowires, J. Nanobiotechnology, 18, 152, 10.1186/s12951-020-00712-4 · doi:10.1186/s12951-020-00712-4
- Ghanavati, 2020, A novel label-free impedimetric immunosensor for sensitive detection of prostate specific antigen using Au nanoparticles/MWCNTs- graphene quantum dots nanocomposite, Microchem. J., 159, 105301, 10.1016/j.microc.2020.105301 · doi:10.1016/j.microc.2020.105301
- Subramanian, 2014, An impedimetric immunosensor based on diamond nanowires decorated with nickel nanoparticles, Analyst, 139, 1726, 10.1039/c3an02045b · doi:10.1039/c3an02045b
- Teimouri, 2019, The highly sensitive impedimetric biosensor in label free approach for hepatitis B virus DNA detection based on tellurium doped ZnO nanowires, Appl. Phys. A, 125, 616, 10.1007/s00339-019-2890-4 · doi:10.1007/s00339-019-2890-4
- Sandil, 2019, Protein-functionalized WO3 nanorods–based impedimetric platform for sensitive and label-free detection of a cardiac biomarker, J. Mater. Res., 34, 1331, 10.1557/jmr.2018.481 · doi:10.1557/jmr.2018.481
- Alfadaly, R.A., Elsayed, A., Hassan, R.Y.A., Noureldeen, A., Darwish, H., and Gebreil, A.S. (2021). Microbial Sensing and Removal of Heavy Metals: Bioelectrochemical Detection and Removal of Chromium(VI) and Cadmium(II). Molecules, 26. · doi:10.3390/molecules26092549
- Fu, 2016, Label-Free Detection of Chondroitin Sulphate Proteoglycan 4 by a Polyaniline/Graphene Nanocomposite Functionalized Impedimetric Immunosensor, J. Nanomater., 2016, 7834657, 10.1155/2016/7834657 · doi:10.1155/2016/7834657
- Abdullah, 2014, PANI-Ag-Cu Nanocomposite Thin Films Based Impedimetric Microbial Sensor for Detection of E. coli Bacteria, J. Nanomater., 2014, 951640, 10.1155/2014/951640 · doi:10.1155/2014/951640
- Fusco, 2017, AuNPs-functionalized PANABA-MWCNTs nanocomposite-based impedimetric immunosensor for 2,4-dichlorophenoxy acetic acid detection, Biosens. Bioelectron., 93, 52, 10.1016/j.bios.2016.10.016 · doi:10.1016/j.bios.2016.10.016
- Zaino, 2016, Nanopore-enabled electrode arrays and ensembles, Microchim. Acta, 183, 1019, 10.1007/s00604-015-1701-7 · doi:10.1007/s00604-015-1701-7
- Hou, 2011, Biomimetic smart nanopores and nanochannels, Chem. Soc. Rev., 40, 2385, 10.1039/c0cs00053a · doi:10.1039/c0cs00053a
- Wu, 2015, Impedance sensing of DNA immobilization and hybridization by microfabricated alumina nanopore membranes, Sens. Actuators B: Chem., 216, 105, 10.1016/j.snb.2015.03.094 · doi:10.1016/j.snb.2015.03.094
- Yang, 2008, Study on the activity and stability of urease immobilized onto nanoporous alumina membranes, Microporous Mesoporous Mater., 111, 359, 10.1016/j.micromeso.2007.08.009 · doi:10.1016/j.micromeso.2007.08.009
- Joung, 2013, A nanoporous membrane-based impedimetric immunosensor for label-free detection of pathogenic bacteria in whole milk, Biosens. Bioelectron., 44, 210, 10.1016/j.bios.2013.01.024 · doi:10.1016/j.bios.2013.01.024
- Jin, 2011, A novel porous anodic alumina based capacitive sensor towards trace detection of PCBs, Sens. Actuators B: Chem., 157, 641, 10.1016/j.snb.2011.05.044 · doi:10.1016/j.snb.2011.05.044
- Nagaraj, 2014, Nanochannel-based electrochemical sensor for the detection of pharmaceutical contaminants in water, Environ. Sci. Process. Impacts, 16, 135, 10.1039/C3EM00406F · doi:10.1039/c3em00406f
- Lillo, 2009, Ion-beam pore opening of porous anodic alumina: The formation of single nanopore and nanopore arrays, Mater. Lett., 63, 457, 10.1016/j.matlet.2008.11.007 · doi:10.1016/j.matlet.2008.11.007
- Tan, 2011, A PDMS microfluidic impedance immunosensor for E. coli O157:H7 and Staphylococcus aureus detection via antibody-immobilized nanoporous membrane, Sens. Actuators B Chem., 159, 328, 10.1016/j.snb.2011.06.074 · doi:10.1016/j.snb.2011.06.074
- Ali, 2013, DNA hybridization detection using less than 10-nm gap silicon nanogap structure, Sens. Actuators A Phys., 199, 304, 10.1016/j.sna.2013.06.008 · doi:10.1016/j.sna.2013.06.008
- Mannoor, 2010, Nanogap Dielectric Spectroscopy for Aptamer-Based Protein Detection, Biophys. J., 98, 724, 10.1016/j.bpj.2009.10.042 · doi:10.1016/j.bpj.2009.10.042
- Okyay, 2017, Using nanogap in label-free impedance based electrical biosensors to overcome electrical double layer effect, Microsyst. Technol., 23, 889, 10.1007/s00542-015-2764-4 · doi:10.1007/s00542-015-2764-4
- Ramnani, 2019, Graphene nanogap electrodes in electrical biosensing, Biosens. Bioelectron., 126, 838, 10.1016/j.bios.2018.11.049 · doi:10.1016/j.bios.2018.11.049
Cited by
Electrochemical Impedance Spectroscopy─A Tutorial
Lazanas, A. C., & Prodromidis, M. I. (2023) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.2c00070 · Cited by 3,123
Impedance Analysis of Electrochemical Systems
Vivier, V., & Orazem, M. E. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00876 · Cited by 615
Current trends in blood biomarker detection and imaging for Alzheimer’s disease
Hu, S., Yang, C., & Luo, H. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114278 · Cited by 84
Evaluation Method of Internal Resistance for Repurposing Using Middle and Large-Sized Batteries
Lim, M.-G., Jung, J.-B., Kim, N.-H., Kim, J.-M., Shen, J., & Rho, D.-S. (2023) · Energies · doi:10.3390/en16155652 · Cited by 11
Al-Hiyali, M. I., Kannan, R., Alharthi, Y. Z., & Shutari, H. (2024) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ad7b7a · Cited by 7
Metadata
- Authors
- Magar, H. S., Hassan, R. Y. A., & Mulchandani, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-10-01
- Volume
- 21
- Issue
- 19
- Pages
- 6578
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3202325891
- Cited by
- 1,335
- References
- 65
- FWCI
- 44.93
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- National Institute of Justice (2019-NE-BX-006)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications. https://app.cochat.ai/papers/10.3390/s21196578
- The paper
- Magar, H. S., Hassan, R. Y. A., & Mulchandani, A. (2021). Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications. Sensors. https://doi.org/10.3390/s21196578
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.