The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Interactive variable selection (IVS) for PLS. Part 1: Theory and algorithms
Abstract
A modified PLS algorithm is introduced with the goal of achieving improved prediction ability. The method, denoted IVS‐PLS, is based on dimension‐wise selective reweighting of single elements in the PLS weight vector w. Cross‐validation, a criterion for the estimation of predictive quality, is used for guiding the selection procedure in the modelling stage. A threshold that controls the size of the selected values in w is put inside a cross‐validation loop. This loop is repeated for each dimension and the results are interpreted graphically. The manipulation of w leads to rotation of the classical PLS solution. The results of IVS‐PLS are different from simply selecting X‐variables prior to modelling. The theory is explained and the algorithm is demonstrated for a simulated data set with 200 variables and 40 objects, representing a typical spectral calibration situation with four analytes. Improvements of up to 70% in external PRESS over the classical PLS algorithm are shown to be possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cramer, R. D., Patterson, D. E., & Bunce, J. D. (1988) · Journal of the American Chemical Society · doi:10.1021/ja00226a005 · Cited by 3,931
Wold, S., Ruhe, A., Wold, H., & Dunn, III (1984) · SIAM Journal on Scientific and Statistical Computing · doi:10.1137/0905052 · Cited by 2,529
Self-citation
Cited by
Application of genetic algorithm-PLS for feature selection in spectral data sets
Leardi, R. (2000) · Journal of Chemometrics · doi:10.1002/1099-128x(200009/12)14:5/6<643::aid-cem621>3.0.co;2-e · Cited by 565
Some recent developments in PLS modeling
Wold, S., Trygg, J., Berglund, A., & Antti, H. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00156-3 · Cited by 559
Self-citationPLS generalised linear regression
Bastien, P., Vinzi, V. E., & Tenenhaus, M. (2005) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2004.02.005 · Cited by 281
Per Aspera Ad Astra : Application of Simplex Qsar Approach in Antiviral Research
Muratov, E. N., Artemenko, A. G., Varlamova, E. V., Polischuk, P. G., Lozitsky, V. P., Fedchuk, A. S., Lozitska, R. L., Gridina, T. L., Koroleva, L. S., Sil’nikov, V. N., et al. (2010) · Future Medicinal Chemistry · doi:10.4155/fmc.10.194 · Cited by 64
Metadata
- Authors
- Lindgren, F., Geladi, P., Rännar, S., & Wold, S.
- Venue
- Journal of Chemometrics
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 8
- Issue
- 5
- Pages
- 349-363
- ISSN
- 0886-9383 (ISSN-L)
- 1099-128X
- OpenAlex
- W1965786603
- Cited by
- 217
- References
- 2
- FWCI
- 4.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interactive variable selection (IVS) for PLS. Part 1: Theory and algorithms. https://app.cochat.ai/papers/10.1002/cem.1180080505
- The paper
- Lindgren, F., Geladi, P., Rännar, S., & Wold, S. (1994). Interactive variable selection (IVS) for PLS. Part 1: Theory and algorithms. Journal of Chemometrics. https://doi.org/10.1002/cem.1180080505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.