The DOI matches its Crossref record.
Simple Bisthiocarbonohydrazones as Sensitive, Selective, Colorimetric, and Switch‐On Fluorescent Chemosensors for Fluoride Anions
Abstract
Bisthiocarbonohydrazones are found to be a class of sensitive, selective, ratiometric, and colorimetric chemosensors for anions such as fluoride (F−) or acetate (Ac−). The sensitivities, or the binding constants of the sensors with anions, were found to be strongly dependent on the substituents appended on the π‐conjugation framework, the delocalization bridge CHN, the aromatic moiety, and the hetero atom in the CX group (X=O, S) of the sensors. Single‐crystal structures and 1 H NMR titration analysis shows that the CHN moiety is a hydrogen‐bond donor, and it is proposed that an additional CH⋅⋅⋅F hydrogen bond is formed for the sensors in the presence F−. A sensor bearing anthracenyl groups is demonstrated as a switch‐on fluorescent chemosensor for F− and Ac−. The recognition of F− in acetonitrile (MeCN) by a sensor with nitrophenyl substituents is tolerant to MeOH (MeCN/MeOH=10:1, v/v) and water (MeCN/H 2 O=30:1, v/v); at these solvent ratios the absorption intensity of the sensor–F− complex solution at maximal absorption wavelength was attenuated to half of the original value in pure MeCN.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of Supramolecular Anion Recognition
Busschaert, N., Caltagirone, C., Van Rossom, W., & Gale, P. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00099 · Cited by 1,249
Fluorescence and Colorimetric Chemosensors for Fluoride-Ion Detection
Zhou, Y., Zhang, J. F., & Yoon, J. (2014) · Chemical Reviews · doi:10.1021/cr400352m · Cited by 1,072
Anion receptor chemistry: highlights from 2007
Caltagirone, C., & Gale, P. A. (2009) · Chem. Soc. Rev. · doi:10.1039/b806422a · Cited by 859
Recognition and sensing of fluoride anion
Cametti, M., & Rissanen, K. (2009) · Chemical Communications · doi:10.1039/b902069a · Cited by 654
Zhao, H. X., Liu, L. Q., Liu, Z. D., Wang, Y., Zhao, X. J., & Huang, C. Z. (2011) · Chemical Communications · doi:10.1039/c0cc04399k · Cited by 481
Metadata
- Authors
- Han, F., Bao, Y., Yang, Z., Fyles, T. M., Zhao, J., Peng, X., Fan, J., Wu, Y., & Sun, S.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2007-03-16
- Volume
- 13
- Issue
- 10
- Pages
- 2880-2892
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2105271071
- Cited by
- 164
- References
- 0
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simple Bisthiocarbonohydrazones as Sensitive, Selective, Colorimetric, and Switch‐On Fluorescent Chemosensors for Fluoride Anions. https://app.cochat.ai/papers/10.1002/chem.200600904
- The paper
- Han, F., Bao, Y., Yang, Z., Fyles, T. M., Zhao, J., Peng, X., Fan, J., Wu, Y., & Sun, S. (2007). Simple Bisthiocarbonohydrazones as Sensitive, Selective, Colorimetric, and Switch‐On Fluorescent Chemosensors for Fluoride Anions. Chemistry – A European Journal. https://doi.org/10.1002/chem.200600904
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.