CoChat

Fe3N‐Co2N Nanowires Array: A Non‐Noble‐Metal Bifunctional Catalyst Electrode for High‐Performance Glucose Oxidation and H2O2 Reduction toward Non‐Enzymatic Sensing Applications

Zhou, Dan, Cao, Xiaoqin, Wang, Zao, Hao, Shuai, Hou, Xiandeng, Qu, Fengli, Du, Gu, Asiri, Abdullah M., Zheng, Chengbin, Sun, Xuping · 2017 · Chemistry – A European Journal
Cited by 121

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Among reported electrode materials, a nanoarray is an attractive architecture for molecular detection because of its large specific surface area and easy accessibility for target molecules. Here, a new Fe 3 N‐Co 2 N nanowires array grown on carbon cloth (Fe 3 N‐Co 2 N/CC) is reported as a non‐noble‐metal bifunctional catalyst electrode for high‐performance glucose oxidation and H 2 O 2 reduction. As an electrochemical non‐enzymatic sensor for glucose detection, Fe 3 N‐Co 2 N/CC shows a fast response time of 8 s, a low detection limit (LOD) of 77 n m (signal/noise=3), and a high sensitivity of 4333.7 μA m m−1 cm−2. As an H 2 O 2 sensor, it shows a LOD of 59 n m (signal/noise=3) and a sensitivity of 2273.8 μA m m−1 cm−2 with a response time of 2 s. In addition, the proposed sensor is stable with high selectivity, specificity, and reproducibility, and its application for real sample analysis has been successfully demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/chem.201700594

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 121

Metadata

Authors
Zhou, D., Cao, X., Wang, Z., Hao, S., Hou, X., Qu, F., Du, G., Asiri, A. M., Zheng, C., & Sun, X.
Venue
Chemistry – A European Journal
Publisher
Wiley
Published
2017-03-29
Volume
23
Issue
22
Pages
5214-5218
ISSN
  • 0947-6539 (ISSN-L)
  • 1521-3765
OpenAlex
W2594122609
Cited by
121
References
6
FWCI
7.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.