The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Fluorescent Molecular Rotors for Viscosity Sensors
Abstract
Fluorescent molecular rotors (FMRs) can act as viscosity sensors in various media including subcellular organelles and microfluidic channels. In FMRs, the rotation of rotators connected to a fluorescent π‐conjugated bridge is suppressed by increasing environmental viscosity, resulting in increasing fluorescence (FL) intensity. In this minireview, we describe recently developed FMRs including push–pull type π‐conjugated chromophores, meso‐phenyl (borondipyrromethene) (BODIPY) derivatives, dioxaborine derivatives, cyanine derivatives, and porphyrin derivatives whose FL mechanism is viscosity‐responsive. In addition, FMR design strategies for addressing various issues (e.g., obtaining high FL contrast, internal FL references, and FL intensity‐contrast trade‐off) and their biological and microfluidic applications are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Grabowski, Z. R., Rotkiewicz, K., & Rettig, W. (2003) · Chemical Reviews · doi:10.1021/cr940745l · Cited by 3,714
Fluorescent indicators based on BODIPY
Boens, N., Leen, V., & Dehaen, W. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15132k · Cited by 2,262
AIE macromolecules: syntheses, structures and functionalities
Hu, R., Leung, N. L. C., & Tang, B. Z. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00044g · Cited by 1,460
BODIPY-based probes for the fluorescence imaging of biomolecules in living cells
Kowada, T., Maeda, H., & Kikuchi, K. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00030k · Cited by 1,381
Sasaki, S., Drummen, G. P. C., & Konishi, G.-I. (2016) · Journal of Materials Chemistry C · doi:10.1039/c5tc03933a · Cited by 1,189
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
Molecular Rotor Measures Viscosity of Live Cells via Fluorescence Lifetime Imaging
Kuimova, M. K., Yahioglu, G., Levitt, J. A., & Suhling, K. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800570d · Cited by 815
Reinterpretation of the anomalous fluorescense of -n,n-dimethylamino-benzonitrile
Rotkiewicz, K., Grellmann, K. H., & Grabowski, Z. R. (1973) · Chemical Physics Letters · doi:10.1016/0009-2614(73)80367-7 · Cited by 792
Imaging intracellular viscosity of a single cell during photoinduced cell death
Kuimova, M. K., Botchway, S. W., Parker, A. W., Balaz, M., Collins, H. A., Anderson, H. L., Suhling, K., & Ogilby, P. R. (2009) · Nature Chemistry · doi:10.1038/nchem.120 · Cited by 639
Molecular rotors—fluorescent biosensors for viscosity and flow
Haidekker, M. A., & Theodorakis, E. A. (2007) · Org. Biomol. Chem. · doi:10.1039/b618415d · Cited by 638
Umwandlung von Elektronenanregungsenergie
Lippert, E., Lüder, W., Moll, F., Nägele, W., Boos, H., Prigge, H., & Seibold‐Blankenstein, I. (1961) · Angewandte Chemie · doi:10.1002/ange.19610732103 · Cited by 506
Mapping viscosity in cells using molecular rotors
Kuimova, M. K. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41674c · Cited by 484
Activatable Rotor for Quantifying Lysosomal Viscosity in Living Cells
Wang, L., Xiao, Y., Tian, W., & Deng, L. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311688g · Cited by 464
Peng, X., Yang, Z., Wang, J., Fan, J., He, Y., Song, F., Wang, B., Sun, S., Qu, J., Qi, J., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1104014 · Cited by 431
Mammalian Mitochondrial Complex I: Biogenesis, Regulation, and Reactive Oxygen Species Generation
Koopman, W. J. H., Nijtmans, L. G. J., Dieteren, C. E. J., Roestenberg, P., Valsecchi, F., Smeitink, J. A. M., & Willems, P. H. G. M. (2010) · Antioxidants & Redox Signaling · doi:10.1089/ars.2009.2743 · Cited by 411
Molecular Rotors: What Lies Behind the High Sensitivity of the Thioflavin-T Fluorescent Marker
Amdursky, N., Erez, Y., & Huppert, D. (2012) · Accounts of Chemical Research · doi:10.1021/ar300053p · Cited by 411
Stsiapura, V. I., Maskevich, A. A., Kuzmitsky, V. A., Uversky, V. N., Kuznetsova, I. M., & Turoverov, K. K. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp805822c · Cited by 385
Monitoring Biophysical Properties of Lipid Membranes by Environment-Sensitive Fluorescent Probes
Demchenko, A. P., Mély, Y., Duportail, G., & Klymchenko, A. S. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.02.012 · Cited by 381
Schuddeboom, W., Jonker, S. A., Warman, J. M., Leinhos, U., Kuehnle, W., & Zachariasse, K. A. (1992) · The Journal of Physical Chemistry · doi:10.1021/j100205a041 · Cited by 359
A molecular rotor for measuring viscosity in plasma membranes of live cells
López-Duarte, I., Vu, T. T., Izquierdo, M. A., Bull, J. A., & Kuimova, M. K. (2014) · Chem. Commun. · doi:10.1039/c3cc47530a · Cited by 274
Reactive oxygen species mediate modification of glycocalyx during ischemia-reperfusion injury
Rubio-Gayosso, I., Platts, S. H., & Duling, B. R. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00796.2005 · Cited by 262
Ren, M., Deng, B., Zhou, K., Kong, X., Wang, J.-Y., & Lin, W. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04385 · Cited by 261
Fluid shear stress activates YAP1 to promote cancer cell motility
Lee, H. J., Diaz, M. F., Price, K. M., Ozuna, J. A., Zhang, S., Sevick-Muraca, E. M., Hagan, J. P., & Wenzel, P. L. (2017) · Nature Communications · doi:10.1038/ncomms14122 · Cited by 258
The shear stress of it all: the cell membrane and mechanochemical transduction
White, C. R., & Frangos, J. A. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2128 · Cited by 255
Computational Study of Thioflavin T Torsional Relaxation in the Excited State
Stsiapura, V. I., Maskevich, A. A., Kuzmitsky, V. A., Turoverov, K. K., & Kuznetsova, I. M. (2007) · The Journal of Physical Chemistry A · doi:10.1021/jp070590o · Cited by 243
New fluorescent probes for the measurement of cell membrane viscosity
Haidekker, M. A., Ling, T., Anglo, M., Stevens, H. Y., Frangos, J. A., & Theodorakis, E. A. (2001) · Chemistry & Biology · doi:10.1016/s1074-5521(00)90061-9 · Cited by 226
Aleardi, A. M., Benard, G., Augereau, O., Malgat, M., Talbot, J. C., Mazat, J. P., Letellier, T., Dachary-Prigent, J., Solaini, G. C., & Rossignol, R. (2005) · Journal of Bioenergetics and Biomembranes · doi:10.1007/s10863-005-6631-3 · Cited by 224
Motion-induced change in emission (MICE) for developing fluorescent probes
Su, D., Teoh, C. L., Wang, L., Liu, X., & Chang, Y.-T. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00018a · Cited by 223
Leinhos, U., Kuehnle, W., & Zachariasse, K. A. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100158a024 · Cited by 214
Seghrouchni, I., Drai, J., Bannier, E., Rivière, J., Calmard, P., Garcia, I., Orgiazzi, J., & Revol, A. (2002) · Clinica Chimica Acta · doi:10.1016/s0009-8981(02)00099-2 · Cited by 205
Zachariasse, K. A., Grobys, M., von der Haar, T., Hebecker, A., Il'ichev, Y. V., Morawski, O., Rückert, I., & Kühnle, W. (1997) · Journal of Photochemistry and Photobiology A: Chemistry · doi:10.1016/s1010-6030(96)04601-1 · Cited by 196
Grabowski, Z. R., Rotkiewicz, K., & Siemiarczuk, A. (1979) · Journal of Luminescence · doi:10.1016/0022-2313(79)90153-4 · Cited by 154
Kung, C. E., & Reed, J. K. (1986) · Biochemistry · doi:10.1021/bi00368a042 · Cited by 153
Two emitting states of excited p-(9-anthryl)-n,n-dimethylaniline derivatives in polar solvents
Siemiarczuk, A., Grabowski, Z. R., Krówczyński, A., Asher, M., & Ottolenghi, M. (1977) · Chemical Physics Letters · doi:10.1016/0009-2614(77)80411-9 · Cited by 150
Sobolewski, A. L., & Domcke, W. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00724-5 · Cited by 149
Ratiometric mechanosensitive fluorescent dyes: design and applications
Haidekker, M. A., & Theodorakis, E. A. (2016) · Journal of Materials Chemistry C · doi:10.1039/c5tc03504j · Cited by 142
Viscosity Effect on the Ultrafast Bond Twisting Dynamics in an Amyloid Fibril Sensor: Thioflavin-T
Singh, P. K., Kumbhakar, M., Pal, H., & Nath, S. (2010) · The Journal of Physical Chemistry B · doi:10.1021/jp100371s · Cited by 138
The driving forces for twisted or planar intramolecular charge transfer
Zhong, C. (2015) · Physical Chemistry Chemical Physics · doi:10.1039/c4cp02381a · Cited by 137
Sulatskaya, A. I., Lavysh, A. V., Maskevich, A. A., Kuznetsova, I. М., & Константинович, Т. К. (2017) · Scientific Reports · doi:10.1038/s41598-017-02237-7 · Cited by 122
Imaging tumor microscopic viscosity in vivo using molecular rotors
Shimolina, L. E., Izquierdo, M. A., López‐Duarte, I., Bull, J. A., Shirmanova, M. V., Klapshina, L. G., Вадимовна, З. Е., & Kuimova, M. K. (2017) · Scientific Reports · doi:10.1038/srep41097 · Cited by 116
Li, D., Tian, X., Wang, A., Guan, L., Zheng, J., Li, F., Li, S., Zhou, H., Wu, J., & Tian, Y. (2015) · Chemical Science · doi:10.1039/c5sc03956h · Cited by 111
Molecular rotors: synthesis and evaluation as viscosity sensors
Sutharsan, J., Lichlyter, D. J., Wright, N. E., Dakanali, M., Haidekker, M. A., & Theodorakis, E. A. (2010) · Tetrahedron · doi:10.1016/j.tet.2010.01.093 · Cited by 108
Flapping viscosity probe that shows polarity-independent ratiometric fluorescence
Kotani, R., Sotome, H., Okajima, H., Yokoyama, S., Nakaike, Y., Kashiwagi, A., Mori, C., Nakada, Y., Yamaguchi, S., Osuka, A., et al. (2017) · Journal of Materials Chemistry C · doi:10.1039/c7tc01533j · Cited by 104
Kosower, E. M., & Dodiuk, H. (1976) · Journal of the American Chemical Society · doi:10.1021/ja00420a010 · Cited by 104
Karpenko, J., Niko, Y., Yakubovskyi, V. P., Gerasov, A. O., Bonnet, D., Kovtun, Y. P., & Klymchenko, A. S. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc03411f · Cited by 99
The photophysical properties of a julolidene-based molecular rotor
Allen, B., Benniston, A. C., Harriman, A., Rostron, S. A., & Yu, C. (2005) · Physical Chemistry Chemical Physics · doi:10.1039/b507165h · Cited by 98
A versatile fluorescent probe for imaging viscosity and hypochlorite in living cells
Wang, X., Song, F., & Peng, X. (2015) · Dyes and Pigments · doi:10.1016/j.dyepig.2015.10.012 · Cited by 85
A Simple BODIPY-Based Viscosity Probe for Imaging of Cellular Viscosity in Live Cells
Su, D., Teoh, C. L., Gao, N., Xu, Q., & Chang, Y. (2016) · Sensors · doi:10.3390/s16091397 · Cited by 83
Narayanaswamy, N., Das, S., Samanta, P. K., Banu, K., Sharma, G. P., Mondal, N., Dhar, S. K., Pati, S. K., & Govindaraju, T. (2015) · Nucleic Acids Research · doi:10.1093/nar/gkv875 · Cited by 80
Characterization of changes in the viscosity of lipid membranes with the molecular rotor FCVJ
Nipper, M. E., Majd, S., Mayer, M., Lee, J. C., Theodorakis, E. A., & Haidekker, M. A. (2008) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2008.01.005 · Cited by 77
Self-citationSebastiao, M., Quittot, N., & Bourgault, S. (2017) · Analytical Biochemistry · doi:10.1016/j.ab.2017.06.007 · Cited by 74
Bennet, M. A., Richardson, P., Arlt, J., McCarthy, A., Buller, G. S., & Jones, A. C. (2011) · Lab on a Chip · doi:10.1039/c1lc20391f · Cited by 71
Carufel, C. A. D., Quittot, N., Nguyen, P. T., & Bourgault, S. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201507092 · Cited by 70
Chandross, E. A., & Thomas, H. T. (1971) · Chemical Physics Letters · doi:10.1016/0009-2614(71)80252-x · Cited by 64
Khalil, O. S., Hofeldt, R. H., & McGlynn, S. P. (1972) · Chemical Physics Letters · doi:10.1016/0009-2614(72)85084-x · Cited by 60
Vyšniauskas, A., Qurashi, M., & Kuimova, M. K. (2016) · Chemistry - A European Journal · doi:10.1002/chem.201601925 · Cited by 60
Xia, T., Wang, L., Qu, Y., Rui, Y., Cao, J., Hu, Y., Yang, J., Wu, J., & Xu, J. (2016) · Journal of Materials Chemistry C · doi:10.1039/c6tc01241h · Cited by 56
Intrinsic and Extrinsic Temperature-Dependency of Viscosity-Sensitive Fluorescent Molecular Rotors
Howell, S. G., Dakanali, M., Theodorakis, E. A., & Haidekker, M. A. (2011) · Journal of Fluorescence · doi:10.1007/s10895-011-0979-z · Cited by 55
Cazeau-Dubroca, C., Peirigua, A., Lyazidi, S. A., & NOUCHI, G. (1983) · Chemical Physics Letters · doi:10.1016/0009-2614(83)80099-2 · Cited by 51
Khalil, O. S., Hofeldt, R. H., & McGlynn, S. P. (1973) · Journal of Luminescence · doi:10.1016/0022-2313(73)90019-7 · Cited by 43
Zhu, D., Haidekker, M. A., Lee, J., Won, Y., & Lee, J. C. (2007) · Macromolecules · doi:10.1021/ma0702288 · Cited by 43
Self-citationGao, M., Hong, Y., Chen, B., Wang, Y., Zhou, W., Wong, W. W. H., Zhou, J. Q., Smith, T. A., & Zhao, Z. (2017) · Polymer Chemistry · doi:10.1039/c7py00564d · Cited by 36
A triazine-based BODIPY trimer as a molecular viscometer
Raut, S., Kimball, J., Fudala, R., Bora, I., Chib, R., Jaafari, H., Castillo, M., Smith, N. W., Gryczyński, I., Dzyuba, S. V., et al. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp07214j · Cited by 33
On the excimer model of N,N-dialkyl-p-cyanoanilines fluorescence in polar solvents
Khalil, O. S. (1975) · Chemical Physics Letters · doi:10.1016/0009-2614(75)85308-5 · Cited by 26
Solvent effects on intramolecular charge separation
Köhler, G., Wolschann, P., & Rotkiewicz, K. (1992) · Journal of Chemical Sciences · doi:10.1007/bf02863364 · Cited by 15
Carufel, C. A. D., Quittot, N., Nguyen, P. T., & Bourgault, S. (2015) · Angewandte Chemie · doi:10.1002/ange.201507092 · Cited by 5
Cited by
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Recent advances in multifunctional fluorescent probes for viscosity and analytes
Yang, X., Zhang, D., Ye, Y., & Zhao, Y. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214336 · Cited by 340
Metadata
- Authors
- Lee, S., Heo, J., Woo, H. C., Lee, J., Seo, Y. H., Lee, C., Kim, S., & Kwon, O.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2018-08-16
- Volume
- 24
- Issue
- 52
- Pages
- 13706-13718
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2801882715
- Cited by
- 271
- References
- 68
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.