Role of wearable rhythm recordings in clinical decision making—The wEHRAbles project
Open accessAbstract
Background: Multiple wearable devices for rhythm analysis have been developed using either photoplethysmography (PPG) or handheld ECG. Hypothesis: The aim of this survey was to assess impact of these technologies on physicians' clinical decision‐making regarding initiation of diagnostic steps, drug therapy, and invasive strategies. Methods: The online survey included 10 questions on types of devices, advantages, and disadvantages of wearable devices as well as case scenarios for patients with supraventricular arrhythmias and atrial fibrillation (AF). Results: A total of 417 physicians (median age 37 [IQR 32‐43] years) from 42 countries world‐wide completed the survey. When presented a tracing of a regular tachycardia by a symptomatic patient, most participants would trigger further diagnostic steps (90% for single‐lead ECG vs 83% for PPG, P < .001), while a single‐lead ECG would be sufficient to perform an invasive EP study in approximately half of participants (51% vs 22% for PPG, P < .001). When presented with a single‐lead ECG tracing suggesting AF, most participants (90%) would trigger further diagnostic steps. A symptomatic AF patient would trigger anticoagulation treatment to a higher extent as an asymptomatic patient (59% vs 21%, P < .001). PPG tracings would only rarely lead to therapeutic steps regardless of symptoms. Most participants would like scientific society recommendations on the use of wearable devices (62%). Conclusions: Tracings from wearable rhythm devices suggestive of arrhythmias are most likely to trigger further diagnostic steps, and in the case of PPG recordings rarely therapeutic interventions. A majority of participants expect these devices to facilitate diagnostics and arrhythmia screening but fear data overload and expect scientific society recommendations on the use of wearables.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
It is most likely that, when used in clinical practice, PPG-based devices could prompt ECG-based assessment when possible AF is detected, rather than being used for decision making on their own.
“It is most likely that, when used in clinical practice, PPG-based devices could prompt ECG-based assessment when possible AF is detected, rather than being used for decision making on their own”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [202]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438 · see citing works
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418 · see citing works
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901183 · Cited by 1,917 · see citing works
Brugada, J., Katritsis, D. G., Arbelo, E., Arribas, F., Bax, J. J., Blomström‐Lundqvist, C., Calkins, H. G., Corrado, D., Deftereos, S. G., Diller, G., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz467 · Cited by 1,278 · see citing works
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580 · see citing works
Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation
Guo, Y., Wang, H., Zhang, H., Liu, T., Liang, Z., Xia, Y., Yan, L., Xing, Y., Shi, H., Li, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.08.019 · Cited by 489 · see citing works
Accuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386 · see citing works
Görenek, B., Bax, J. J., Boriani, G., Chen, S., Dagres, N., Glotzer, T. V., Healey, J. S., Israel, C. W., Kudaiberdieva, G., Levin, L., et al. (2017) · EP Europace · doi:10.1093/europace/eux163 · Cited by 249 · see citing works
Smartwatch Performance for the Detection and Quantification of Atrial Fibrillation
Wasserlauf, J., You, C., Patel, R., Valys, A., Albert, D., & Passman, R. (2019) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006834 · Cited by 245 · see citing works
Mairesse, G., Moran, P., van Gelder, I. V., Elsner, C., Rosenqvist, M., Mant, J., Banerjee, A., Gorenek, B., Brachmann, J., Varma, N., et al. (2018) · Europace · doi:10.1093/europace/eux177 · Cited by 191 · see citing works
Portable out-of-hospital electrocardiography: A review of current technologies
Bansal, A., & Joshi, R. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12035 · Cited by 174 · cited 1× · see citing works
“Devices utilize two methods for heart rhythm analysis— photoplethysmography (PPG) or ECG (Table 1).(1) PPG is based on light emitting and light sensing diodes that estimate heart rate from changes in blood volume caused by peripheral pulsations.”
MethodBrasier, N., Raichle, C. J., Dörr, M., Becke, A., Nohturfft, V., Weber, S., Bulacher, F., Salomon, L., Noah, T., Birkemeyer, R., et al. (2018) · EP Europace · doi:10.1093/europace/euy176 · Cited by 146 · see citing works
An information theoretic measure for the evaluation of ordinal scale data
Tastle, W. J., & Wierman, M. J. (2006) · Behavior Research Methods · doi:10.3758/bf03192803 · Cited by 59 · see citing works
Väliaho, E., Kuoppa, P., Lipponen, J. A., Martikainen, T. J., Jäntti, H., Rissanen, T. T., Kolk, I., Castrén, M. K., Halonen, J., Tarvainen, M. P., et al. (2019) · EP Europace · doi:10.1093/europace/euz060 · Cited by 39 · see citing works
Vardas, P. E., Cowie, M., Dagres, N., Asvestas, D., Tzeis, S. E., Vardas, E. P., Hindricks, G., & Camm, A. J. (2019) · EP Europace · doi:10.1093/europace/euz249 · Cited by 20 · see citing works
Reverberi, C., Rabia, G., Rosa, F. D., Bosi, D., Botti, A., & Benatti, G. (2019) · BioMed Research International · doi:10.1155/2019/4861951 · Cited by 19 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261 · see citing works
Self-citationWearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
Gawałko, M., Duncker, D., Manninger, M., van der Velden, R. M. J., Hermans, A. N. L., Verhaert, D. V. M., Pison, L., Pisters, R., Hemels, M., Sultan, A., et al. (2021) · EP Europace · doi:10.1093/europace/euab050 · Cited by 106 · see citing works
Self-citationJensen, M. T., Treskes, R. W., Caiani, E. G., Casado-Arroyo, R., Cowie, M. R., Dilaveris, P., Duncker, D., Di Rienzo, M., Frederix, I., De Groot, N., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab011 · Cited by 93 · see citing works
Self-citation
- Authors
- Manninger, M., Kosiuk, J., Zweiker, D., Njeim, M., Antolic, B., Kircanski, B., Larsen, J. M., Svennberg, E., Vanduynhoven, P., & Duncker, D.
- Affiliations
- Medical University of Graz (AT)
- Helios Clinic Koethen Germany
- Saint Joseph University (LB)
- University Medical Centre Ljubljana Department of Cardiology Ljubljana Slovenia
- Clinical Centre of Serbia Pacemaker Centre Belgrade Serbia
- Aalborg University Hospital (DK)
- Karolinska University Hospital (SE)
- Onze Lieve Vrouwziekenhuis Hospital (BE)
- Medizinische Hochschule Hannover (DE)
- Corresponding author
- Duncker, David
- ORCID
- Venue
- Clinical Cardiology
- Publisher
- Wiley
- Published
- 2020-07-22
- Volume
- 43
- Issue
- 9
- Pages
- 1032-1039
- ISSN
- 0160-9289 (ISSN-L)
- 1932-8737
- PMC
- PMC7462183
- OpenAlex
- W3044085570
- Cited by
- 50
- References
- 16
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 5 · 2023: 8 · 2022: 10 · 2021: 15 · 2020: 3
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Clinical Cardiology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion, cc-by)
- Funders
- Deutsche Forschungsgemeinschaft (Open Access Publication Fund)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- wearable devices, photoplethysmography, clinical decision-making, supraventricular arrhythmias, atrial fibrillation, arrhythmia screening, anticoagulation, invasive electrophysiology, physician perceptions, data overload
- MeSH terms
- Clinical Decision-Making, Wearable Electronic Devices, Action Potentials, Adult, Atrial Fibrillation, Electrocardiography, Heart Conduction System, Heart Rate, Humans, Predictive Value of Tests, Prognosis, Tachycardia, Supraventricular, Reproducibility of Results, Photoplethysmography, Health Care Surveys
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review