Background: The identification of patients at increased risk for ventricular tachycardia or ventricular fibrillation (VT/VF) and sudden cardiac death has consequences for therapeutic options and thus may reduce mortality in patients with coronary artery disease (CAD). Hypothesis: We hypothesized that the intra‐QRS fragmentation in magnetocardiographic recordings is increased in patients with CAD and with a history of VT/VF. Methods: Multichannel magnetocardiography (MCG) was carried out in 34 healthy controls, 42 patients with CAD without a history of VT/VF, and 43 patients with CAD and with a history of VT/VF. The intra‐QRS fragmentation was quantified by a new fragmentation score. Its spatial distribution was investigated using two‐dimensional (2‐D) contour maps according to the sensor position of the 49‐channel magnetogradiometer. Results: Patients with CAD and with a history of VT/VF had significantly increased QRS fragmentation compared with patients with CAD without VT/VF or controls (72.9 ± 37.5,48.5 ± 14.3, and 42.5 ± 7.8, respectively; p< 0.05). The area of high fragmentation in 2‐D contour maps was twice as large in patients with than in those without a history of VT/VF (represented by the number of MCG channels with high fragmentation: 26.3 ± 15.5 vs. 12.4 ± 9.9, p<0.0001). Patients prone to VT/VF could be identified with a sensitivity of 64% and a specificity of 90%. Conclusion: In patients with CAD and with a history of VT/VF, intra‐QRS fragmentation is increased and the area of high fragmentation in 2‐D contour maps is enlarged. These findings may be helpful in identifying patients with CAD at risk for malignant tachyarrhythmias.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/clc.4960241009

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 11

Metadata

Authors
Göudde, P., Agrawal, R., Müuller, H. ‐., Czerski, K., Endt, P., Steinhoff, U., Oeff, M., Schultheiss, H. ‐., & Behrens, S.
Venue
Clinical Cardiology
Publisher
Wiley
Published
2001-10
Volume
24
Issue
10
Pages
682-688
ISSN
  • 0160-9289 (ISSN-L)
  • 1932-8737
OpenAlex
W2062106773
Cited by
11
References
4
FWCI
0.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetocardiographic mapping of QRS fragmentation in patients with a history of malignant tachyarrhythmias. https://app.cochat.ai/papers/10.1002/clc.4960241009
The paper
Göudde, P., Agrawal, R., Müuller, H. ‐., Czerski, K., Endt, P., Steinhoff, U., Oeff, M., Schultheiss, H. ‐., & Behrens, S. (2001). Magnetocardiographic mapping of QRS fragmentation in patients with a history of malignant tachyarrhythmias. Clinical Cardiology. https://doi.org/10.1002/clc.4960241009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.