New Technologies for the Evaluation of Acute Coronary Syndromes: Magnetocardiography—The Next Generation of Super Electrocardiogram?
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There is increasing evidence that progress in magnetic sensor technology combined with more advanced signal denoising methods is rapidly reaching the requirements for near-future availability of several novel device variants for budget-price unshielded MCG.
“Instead, as concerns most routine clinical MCG applications, there is an increasing evidence that progress in magnetic sensor technology combined with more advanced signal denoising methods is rapidly reaching the requirements for the near-future availability of several novel device variants for budget-price unshielded MCG, covering the needs of different deployment scenarios, from ED triage for”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [87]
Cites
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261 · see citing works
Yang (2021) · doi:10.1038/s41598-020-79139-8 · Cited by 5,035 · see citing works
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510 · see citing works
ACC/AHA 2002 Guideline Update for Exercise Testing: Summary Article
Gibbons, R. J., Balady, G. J., Bricker, J. T., CHAITMAN, B. R., Fletcher, G. F., Froelicher, V. F., Mark, D. B., McCallister, B. D., Mooss, A. N., O’Reilly, M. G., et al. (2002) · Circulation · doi:10.1161/01.cir.0000034670.06526.15 · Cited by 2,606 · see citing works
Microscopic Theory of Superconductivity
Bardeen, J., Cooper, L. N., & Schrieffer, J. R. (1957) · Physical Review · doi:10.1103/physrev.106.162 · Cited by 2,602 · see citing works
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · see citing works
Testing of Low-Risk Patients Presenting to the Emergency Department With Chest Pain
Amsterdam, E. A., Kirk, J. D., Bluemke, D. A., Diercks, D., Farkouh, M. E., Garvey, J. L., Kontos, M. C., McCord, J., Miller, T. D., Morise, A. P., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181ec61df · Cited by 605 · see citing works
National Hospital Ambulatory Medical Care Survey: 2001 emergency department summary.
McCaig, L. F., & Burt, C. W. (2003) · PubMed · Cited by 582 · see citing works
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361 · see citing works
J Wave Syndromes Consensus Conference: Emerging Concepts & Gaps in Knowledge
Antzelevitch, C., Yan, G.-X., Ackerman, M., Borggrefe, M., Corrado, D., Guo, J.-H., Gussak, I., Hasdemir, C., Horie, M., Huikuri, H., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.05.024 · Cited by 239 · see citing works
Does This Patient With Chest Pain Have Acute Coronary Syndrome?
Fanaroff, A. C., Rymer, J. A., Goldstein, S. A., Simel, D. L., & Newby, L. K. (2015) · JAMA · doi:10.1001/jama.2015.12735 · Cited by 228 · see citing works
Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I
Boeddinghaus, J., Nestelberger, T., Koechlin, L., Wussler, D. N., López‐Ayala, P., Walter, J. E., Troester, V., Ratmann, P. D., Seidel, F., Zimmermann, T., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.12.065 · Cited by 177 · see citing works
100 Years of Superconductivity
(2011) · CRC Press eBooks · doi:10.1201/b11312 · Cited by 175 · see citing works
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174 · see citing works
Self-citationA National Study of the Prevalence of Life-Threatening Diagnoses in Patients With Chest Pain
Hsia, R. Y.-J., Hale, Z. E., & Tabas, J. A. (2016) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2016.2498 · Cited by 174 · see citing works
Holland, R. P., & Brooks, H. L. (1975) · Circulation Research · doi:10.1161/01.res.37.4.471 · Cited by 148 · see citing works
Tao, R., Zhang, S., Huang, X., Tao, M., Ma, J., Ma, S., Zhang, C., Zhang, T., Tang, F., Lu, J., et al. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2877649 · Cited by 147 · see citing works
Cohen, D., & Kaufman, L. A. (1975) · Circulation Research · doi:10.1161/01.res.36.3.414 · Cited by 131 · see citing works
Magnetocardiography Predicts Coronary Artery Disease in Patients with Acute Chest Pain
Park, J., Hill, P. M., Chung, N., Hugenholtz, P. G., & Jung, F. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00634.x · Cited by 109 · see citing works
Kwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103 · see citing works
BROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99 · see citing works
Kardesch, M., HOGANCAMP, C. E., & Bing, R. J. (1958) · Circulation Research · doi:10.1161/01.res.6.6.715 · Cited by 98 · see citing works
Tolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A. (2006) · Cardiology · doi:10.1159/000093490 · Cited by 78 · see citing works
Self-citationHänninen, H., Takala, P., Mäkijärvi, M., Montonen, J., Korhonen, P., Oikarinen, L., Nenonen, J., Katila, T., & Toivonen, L. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00380.x · Cited by 74 · see citing works
McClelland, A. J. J., Owens, C. G., Menown, I. B. A., Lown, M. T., & Adgey, A. A. J. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00619-2 · Cited by 73 · see citing works
Cardiac Extracellular Potentials
Spach, M. S., Barr, R. C., Johnson, E. A., & Kootsey, J. M. (1973) · Circulation Research · doi:10.1161/01.res.33.4.465 · Cited by 72 · see citing works
Pena, M. E., Pearson, C., Goulet, M. P., Kazan, V. M., DeRita, A. L., Szpunar, S. M., & Dunne, R. (2020) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2019.100466 · Cited by 71 · see citing works
Yamada, S., & Yamaguchi, I. (2005) · Internal Medicine · doi:10.2169/internalmedicine.44.1 · Cited by 70 · see citing works
Possible sources of new information in the magnetocardiogram
Wikswo, J. P., & Barach, J. P. (1982) · Journal of Theoretical Biology · doi:10.1016/0022-5193(82)90350-2 · Cited by 68 · see citing works
Oikarinen, L., PAAVOLA, M., Montonen, J., Viitasalo, M. T., Mäkijärvi, M. A., Toivonen, L. K., & Katila, T. E. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb00013.x · Cited by 65 · see citing works
Tsukada, K., Miyashita, T., Kandori, A., Mitsui, T., Terada, Y., Sato, M., Shiono, J., Horigome, H., Yamada, S., & Yamaguchi, I. (2000) · International journal of cardiac imaging · doi:10.1023/a:1006376326755 · Cited by 64 · see citing works
Hänninen, H., Takala, P., Mäkijärvi, M. A., Montonen, J., Korhonen, P., Oikarinen, L., Simelius, K., Nenonen, J., Katila, T. E., & Toivonen, L. K. (2001) · Basic Research in Cardiology · doi:10.1007/s003950170049 · Cited by 63 · see citing works
The magnetocardiogram in cardiac disorders
SAARINEN, M., Karp, P., Katila, T. E., & SILTANEN, P. (1974) · Cardiovascular Research · doi:10.1093/cvr/8.6.820 · Cited by 61 · see citing works
Solving the inverse problem in magnetocardiography
Nenonen, J. (1994) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.310989 · Cited by 59 · see citing works
A 3-D model-based registration approach for the PET, MR and MCG cardiac data fusion
Mäkelä, T. J., Pham, Q. C., Clarysse, P., Nenonen, J., Lötjönen, J. M. P., Sipilä, O., Hänninen, H., Lauerma, K., Knuuti, J. M., Katila, T. E., et al. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(03)00012-4 · Cited by 58 · see citing works
Identification of ischemic heart disease via machine learning analysis on magnetocardiograms
Tantimongcolwat, T., Naenna, T., Isarankura-Na-Ayudhya, C., Embrechts, M. J., & Prachayasittikul, V. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.04.009 · Cited by 57 · see citing works
Electrically silent magnetic fields
Roth, B. J., & Wikswo, J. P. (1986) · Biophysical Journal · doi:10.1016/s0006-3495(86)83513-5 · Cited by 57 · see citing works
Cohen, D., Norman, J. C., Molokhia, F., & Hood, W. (1971) · Science · doi:10.1126/science.172.3990.1329 · Cited by 53 · see citing works
Kanzaki, H., Nakatani, S., Kandori, A., Tsukada, K., & Miyatake, K. (2003) · Basic Research in Cardiology · doi:10.1007/s00395-003-0392-0 · Cited by 53 · see citing works
Lim, H. K., Kwon, H., Chung, N., Ko, Y.-G., Kim, J.-M., Kim, I.-S., & Park, Y.-K. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.10.013 · Cited by 52 · see citing works
KORHONEN, P., HUSA, T., TIERALA, I., VÄÄNÄNEN, H., MÄKIJÄRVI, M., KATILA, T., & TOIVONEN, L. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00332.x · Cited by 51 · see citing works
Cohen, D., Savard, P., Rifkin, R. D., Lepeschkin, E., & Strauss, W. E. (1983) · Circulation Research · doi:10.1161/01.res.53.2.274 · Cited by 51 · see citing works
Conversion of magnetocardiographic recordings between two different multichannel SQUID devices
Burghoff, M., Nenonen, J., Trahms, L., & Katila, T. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846680 · Cited by 51 · see citing works
Measurements and a Simplified Interpretation of Magnetocardiograms from Humans
Cohen, D. A., & Chandler, L. (1969) · Circulation · doi:10.1161/01.cir.39.3.395 · Cited by 50 · see citing works
Hänninen, H., Takala, P., Korhonen, P., Oikarinen, L., Mäkijärvi, M., Nenonen, J., Katila, T., & Toivonen, L. (2002) · Annals of Medicine · doi:10.1080/07853890252953518 · Cited by 49 · see citing works
Zheng, W., Su, S., Zhang, G., Bi, X., & Lin, Q. (2019) · Biomedical Optics Express · doi:10.1364/boe.380314 · Cited by 49 · see citing works
Non-invasive imaging of arrhythmogenic left-ventricular myocardium after infarction
Leder, U., Haueisen, J., Huck, M., & Nowak, H. (1998) · The Lancet · doi:10.1016/s0140-6736(98)00082-8 · Cited by 48 · see citing works
Kwon, H., Kim, K., Lee, Y.-H., Kim, J.-M., Yu, K. K., Chung, N., & Ko, Y.-G. (2010) · Circulation Journal · doi:10.1253/circj.cj-09-0975 · Cited by 47 · see citing works
The normal human magnetocardiogram. II. A multipole analysis.
Karp, P., Katila, T., Saarinen, M., SILTANEN, P., & Varpula, T. (1980) · Circulation Research · doi:10.1161/01.res.47.1.117 · Cited by 43 · see citing works
Savard, P., Cohen, D., Lepeschkin, E., Cuffin, B. N., & Madias, J. E. (1983) · Circulation Research · doi:10.1161/01.res.53.2.264 · Cited by 43 · see citing works
Magnetocardiogram recordings in a nonshielded environment—reproducibility and ischemia detection
Steinberg, B. A., Roguin, A., Watkins, S. P., Hill, P., Fernando, D., & Resar, J. R. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.05611.x · Cited by 42 · see citing works
Magnetocardiographic and Electrocardiographic Exercise Mapping in Healthy Subjects
Takala, P., Hänninen, H., Montonen, J., Mäkijärvi, M., Nenonen, J., Oikarinen, L., Simelius, K., Toivonen, L., & Katila, T. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1376388 · Cited by 42 · see citing works
Clinical utility of magnetocardiography in cardiology for the detection of myocardial ischemia
Camm, A. J., Henderson, R., Brisinda, D., Body, R., Charles, R. G., Varcoe, B., & Fenici, R. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.07.009 · Cited by 42 · see citing works
Self-citationKandori, A., Kanzaki, H., Miyatake, K., Hashimoto, S., Itoh, S., Tanaka, N., Miyashita, T., & Tsukada, K. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345262 · Cited by 41 · see citing works
Dutz, S., Bellemann, M. E., Leder, U., & Haueisen, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/1/011 · Cited by 39 · see citing works
Hailer, B., Leeuwen, P. V., Lange, S., & Wehr, M. (1999) · Journal of Electrocardiology · doi:10.1016/s0022-0736(99)90103-6 · Cited by 39 · see citing works
A portable diagnostic device for cardiac magnetic field mapping
Mooney, J. W., Ghasemi-Roudsari, S., Banham, E. R., Symonds, C., Pawlowski, N., & Varcoe, B. T. H. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/3/1/015008 · Cited by 39 · see citing works
A Shielded Facility for Low-Level Magnetic Measurements
Cohen, D. (1967) · Journal of Applied Physics · doi:10.1063/1.1709590 · Cited by 38 · see citing works
Shin, E., Lam, Y., Her, A., Brachmann, J., Jung, F., & Park, J. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.11.165 · Cited by 38 · see citing works
Part III the effect of the torso boundaries on the magnetocardiogram
Hosaka, H., Cohen, D., Cuffin, B. N., & Horáček, B. M. (1976) · Journal of Electrocardiology · doi:10.1016/s0022-0736(76)80042-8 · Cited by 38 · see citing works
Spatial Distribution of Repolarization Times in Patients with Coronary Artery Disease
Leeuwen, P. V., Hailer, B., Lange, S., & Grönemeyer, D. H. W. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00256.x · Cited by 37 · see citing works
Park, J. W., & Jung, F. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.050 · Cited by 37 · see citing works
The normal magnetocardiogram: I Morphology.
Saarinen, M., SILTANEN, P., Karp, P., & Katila, T. E. (1978) · PubMed · Cited by 34 · see citing works
Linear estimation theory applied to the reconstruction of a 3-D vector current distribution.
Smith, W. E., Dallas, W. J., Kullmann, W., & Schlitt, H. (1990) · Applied Optics · doi:10.1364/ao.29.000658 · Cited by 32 · see citing works
Part I Abnormal patterns and physiological variations in magnetocardiograms
Cohen, D., Lepeschkin, E., Hosaka, H., Massell, B. F., & Myers, G. S. (1976) · Journal of Electrocardiology · doi:10.1016/s0022-0736(76)80040-4 · Cited by 32 · see citing works
Haberkorn, W., Steinhoff, U., Burghoff, M., Kosch, O., Morguet, A. J., & Koch, H. C. (2006) · BioMagnetic Research and Technology · doi:10.1186/1477-044x-4-5 · Cited by 31 · see citing works
On, K., Watanabe, S., Yamada, S., Takeyasu, N., Nakagawa, Y., Nishina, H., Morimoto, T., Aihara, H., Kimura, T., Sato, Y., et al. (2007) · Circulation Journal · doi:10.1253/circj.71.1586 · Cited by 31 · see citing works
Magnetocardiography in coronary artery disease with a new system in an unshielded setting
Hailer, B., Chaikovsky, I. A., Auth‐Eisernitz, S., Schäfer, H., Steinberg, F., & Grönemeyer, D. H. W. (2003) · Clinical Cardiology · doi:10.1002/clc.4960261007 · Cited by 30 · see citing works
Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-141912 · Cited by 29 · see citing works
FENICI, R., NENONEN, J., PESOLA, K., KORHONEN, P., LÖTJÖNEN, J., MÄKIJÄRVI, M., TOIVONEN, L., POUTANEN, V., KETO, P., & KATILA, T. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00602.x · Cited by 29 · see citing works
Self-citationGreen, L. S., Lux, R. L., Stilli, D., Haws, C. W., & TACCARDI, B. (1987) · Journal of Electrocardiology · doi:10.1016/0022-0736(87)90003-3 · Cited by 29 · see citing works
Use of a superconducting instrumentation for biomagnetic measurements performed in a hospital
Barbanera, S., Carelli, P., Fenici, R., Leoni, R., Modena, I., & Romani, G. (1981) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1981.1061052 · Cited by 29 · see citing works
Self-citationAgarwal, R. K., Saini, A., Alyousef, T., & Umscheid, C. A. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2012.00538.x · Cited by 28 · see citing works
Detection of patients with coronary artery disease using cardiac magnetic field mapping at rest
Gapelyuk, A., Wessel, N., Fischer, R., Zacharzowsky, U. B., Koch, L., Selbig, D., Schütt, H., Sawitzki, B., Luft, F. C., Dietz, R., et al. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2007.03.013 · Cited by 28 · see citing works
Takala, P., Hänninen, H., Montonen, J., Korhonen, P. E., Mäkijärvi, M. A., Nenonen, J., Oikarinen, L., Toivonen, L., & Katila, T. E. (2002) · Basic Research in Cardiology · doi:10.1007/s395-002-8391-y · Cited by 28 · see citing works
Steinisch, M., Torke, P. R., Haueisen, J., Hailer, B., Grönemeyer, D. H. W., Leeuwen, P. V., & Comani, S. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2012.11.014 · Cited by 28 · see citing works
Kawakami, S., Takaki, H., Hashimoto, S., Kimura, Y., Nakashima, T., Aiba, T., KUSANO, K. F., Kamakura, S., Yasuda, S., & Sugimachi, M. (2016) · Circulation Journal · doi:10.1253/circj.cj-16-0683 · Cited by 27 · see citing works
Park, J.-W., Leithäuser, B., Vršansky, M., & Jung, F. (2008) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-2008-1064 · Cited by 27 · see citing works
Nenonen, J., Pesola, K., H[auml ]nninen, H., Lauerma, K., Takala, P., M[auml ]kel[auml ], T., M[auml ]kij[auml ]rvi, M., Knuuti, J., Toivonen, L., & Katila, T. (2001) · Journal of Electrocardiology · doi:10.1054/jelc.2001.28824 · Cited by 27 · see citing works
Korhonen, P., Väänänen, H., Mäkijärvi, M. A., Katila, T. E., & Toivonen, L. K. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00772.x · Cited by 26 · see citing works
Escalona-Vargas, D., Bolin, E. H., Lowery, C. L., Siegel, E. R., & Eswaran, H. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abc353 · Cited by 26 · see citing works
Brisinda, D., Meloni, A. M., & Fenici, R. (2003) · Lecture notes in computer science · doi:10.1007/3-540-44883-7_13 · Cited by 25 · see citing works
Self-citationPhantom Validation of Multichannel Magnetocardiography Source Localization
Fenici, R., Brisinda, D., Nenonen, J., & Fenici, P. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00063.x · Cited by 25 · see citing works
Self-citationJurkko, R., Mäntynen, V., Tapanainen, J. M., Montonen, J., Väänänen, H., Parikka, H. J., & Toivonen, L. K. (2008) · EP Europace · doi:10.1093/europace/eun335 · Cited by 25 · see citing works
Hänninen, H., Takala, P., Mäkijärvi, M. A., Korhonen, P., Oikarinen, L., Simelius, K., Nenonen, J., Katila, T. E., & Toivonen, L. K. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)02052-5 · Cited by 24 · see citing works
Fragmentation of bandpass-filtered QRS-complex of patients prone to malignant arrhythmia
ENDT, P., Hahlbohm, H.-D., Kreiseler, D., Oeff, M., Steinhoff, U., & Trahms, L. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02518875 · Cited by 24 · see citing works
Magnetocardiography and exercise testing
Brockmeier, K., Comani, S., Erné, S. N., Di Luzio, S., Pasquarelli, A., & Romani, G. L. (1994) · Journal of Electrocardiology · doi:10.1016/s0022-0736(05)80096-2 · Cited by 24 · see citing works
A vector magnetometer module for biomagnetic application
Burghoff, M., Schleyerbach, H., Drung, D., Trahms, L., & Koch, H. (1999) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.783920 · Cited by 22 · see citing works
Application of superconducting magnetometers to the measurement of the vector magnetocardiogram
Wikswo, J., & Fairbank, W. (1977) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1977.1059333 · Cited by 22 · see citing works
Fenici, R., Brisinda, D., Venuti, A., & Sorbo, A. R. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.07.238 · Cited by 22 · see citing works
Self-citationEvaluating Chest Pain in the Emergency Department
Januzzi, J. L., & McCarthy, C. P. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.065 · Cited by 22 · see citing works
Park, J., Leithäuser, B., Hill, P., & Jung, F. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00217.x · Cited by 21 · see citing works
High-resolution isofield mapping in magnetocardiography
Erne, S. N., Fenici, R., Hahlbohm, H.-D., Jaszczuk, W., Lehmann, H. P., & Masselli, M. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455932 · Cited by 21 · see citing works
Self-citationSubtraction Magnetocardiogram for Detecting Coronary Heart Disease
Kandori, A., Ogata, K., Miyashita, T., Takaki, H., Kanzaki, H., Hashimoto, S., Shimizu, W., Kamakura, S., Watanabe, S., & Aonuma, K. (2010) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2010.00392.x · Cited by 20 · see citing works
Ikefuji, H., Nomura, M., Nakaya, Y., Mori, T., Kondo, N., 家石, 潔., Fujimoto, S., & Ito, S. (2007) · The Journal of Medical Investigation · doi:10.2152/jmi.54.116 · Cited by 20 · see citing works
Wu, Y., Lin, L. C., Tseng, W., Liu, Y., Kao, H.-L., Lin, M. S., Huang, H. C., Wang, S. Y., Horng, H. E., Yang, H. C., et al. (2014) · PubMed Central · Cited by 20 · see citing works
An Integrated Maximum Current Density Approach for Noninvasive Detection of Myocardial Infarction
Zhao, C., Jiang, S., Wu, Y., Zhu, J., Zhou, D., Hailer, B., Grönemeyer, D. H. W., & Leeuwen, P. V. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2649570 · Cited by 20 · see citing works
Ghasemi-Roudsari, S., Al-Shimary, A., Varcoe, B., Byrom, R., Kearney, L., & Kearney, M. (2018) · PLoS ONE · doi:10.1371/journal.pone.0191241 · Cited by 19 · see citing works
Chaikovsky, I., Hailer, B., Sosnytskyy, V., Lutay, M., Mjasnikov, G., Kazmirchuk, A., Bydnyk, M., Lomakovskyy, A., & Sosnytskaja, T. (2014) · Coronary Artery Disease · doi:10.1097/mca.0000000000000107 · Cited by 19 · see citing works
Forty Years of Magnetocardiology
Stroink, G. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-12197-5_1 · Cited by 19 · see citing works
Diagnostic outcomes of magnetocardiography in patients with coronary artery disease.
Li, Y., Che, Z., Quan, W., Yuan, R., Shen, Y., Liu, Z., Wang, W., Huigen, J., & Lü, G. (2015) · PubMed Central · Cited by 19 · see citing works
Comparative study of the normal vector magnetocardiogram and vector electrocardiogram
Nousiainen, J., Tech, Lekkala, J. O., Tech, & Malmivuo, J. A. (1986) · Journal of Electrocardiology · doi:10.1016/s0022-0736(86)80037-1 · Cited by 19 · see citing works
Sorbo, A. R., Lombardi, G., La Brocca, L., Guida, G., Fenici, R., & Brisinda, D. (2018) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12526 · Cited by 18 · see citing works
Self-citationStandard Template of Adult Magnetocardiogram
Kandori, A., Ogata, K., Miyashita, T., Watanabe, Y., Tanaka, K. J., Murakami, M., Oka, Y., Takaki, H., Hashimoto, S., Yamada, Y., et al. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00246.x · Cited by 18 · see citing works
Myocardial viability evaluation using magnetocardiography in patients with coronary artery disease
Morguet, A. J., Behrens, S., Kosch, O., Lange, C., Zabel, M., Selbig, D., Munz, D. L., Schultheiß, H., & Koch, H. C. (2004) · Coronary Artery Disease · doi:10.1097/00019501-200405000-00004 · Cited by 18 · see citing works
Andrei Irimia, A., Swinney, K. R., & Wikswo, J. P. (2009) · Physical Review E · doi:10.1103/physreve.79.051908 · Cited by 18 · see citing works
The Value of Magnetocardiography in the Course of Coronary Intervention
Hailer, B., Leeuwen, P. V., Chaikovsky, I. A., Auth‐Eisernitz, S., Schäfer, H., & Grönemeyer, D. H. W. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.05625.x · Cited by 18 · see citing works
Wu, Y.-W., Lee, C.-M., Liu, Y.-B., Wang, S.-S., Huang, H.-C., Tseng, W.-K., Jui, H.-Y., Wang, S.-Y., Horng, H.-E., Yang, H.-C., et al. (2013) · Circulation Journal · doi:10.1253/circj.cj-12-1170 · Cited by 18 · see citing works
Optimal magnetic sensor vests for cardiac source imaging
Lau, S., Petković, B., & Haueisen, J. (2016) · Sensors · doi:10.3390/s16060754 · Cited by 17 · see citing works
Bridging noninvasive and interventional electroanatomical imaging: role of magnetocardiography
Fenici, R., & Brisinda, D. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2006.10.032 · Cited by 17 · see citing works
Self-citationRepolarization Spatial‐Time Current Abnormalities in Patients with Coronary Heart Disease
Ogata, K., Kandori, A., Watanabe, Y., SUZUKI, A., Tanaka, K. J., Oka, Y., Takaki, H., Kanzaki, H., Nakatani, S., Miyatake, K., et al. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02313.x · Cited by 16 · see citing works
Magnetocardiography scoring system to predict the presence of obstructive coronary artery disease
Shin, E., Park, S. G., Saleh, A., Lam, Y., Bhak, J., Jung, F., Morita, S., & Brachmann, J. (2018) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-189301 · Cited by 16 · see citing works
Shiono, J., Horigome, H., Matsui, A., Terada, Y., Miyashita, T., & Tsukada, K. (2003) · International journal of cardiac imaging · doi:10.1023/a:1022823217232 · Cited by 15 · see citing works
Unshielded fetal magnetocardiography system using two-dimensional gradiometers
Seki, Y., Kandori, A., Kumagai, Y., Ohnuma, M., Ishiyama, A., Ishii, T., Nakamura, Y., Horigome, H., & Chiba, T. (2008) · Review of Scientific Instruments · doi:10.1063/1.2897588 · Cited by 15 · see citing works
The history of electrocardiography
Lüderitz, B., & de Luna, A. B. (2017) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2017.07.014 · Cited by 15 · see citing works
Evaluation of Myocardial Ischemia in Kawasaki Disease Using an Isointegral Map on Magnetocardiogram
Shiono, J., Horigome, H., Matsui, A., Terada, Y., Watanabe, S., Miyashita, T., & Tsukada, K. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.t01-1-00915.x · Cited by 14 · see citing works
Iwakami, N., Aiba, T., Kamakura, S., Takaki, H., Furukawa, T. A., Sato, T. S., Sun, W., Shishido, T., Nishimura, K., Inoue‐Yamada, Y., et al. (2020) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12741 · Cited by 14 · see citing works
Diagnostic accuracy of the magnetocardiograph for patients with suspected acute coronary syndrome
Goodacre, S., Walters, S. J., Qayyum, H., Coffey, F., Carlton, E., Coats, T., Glazebrook, W., & Unitt, L. (2021) · Emergency Medicine Journal · doi:10.1136/emermed-2020-210396 · Cited by 13 · see citing works
Beat to beat surface recording and averaging of his-purkinje activity in man
Erne, S. N., Fenici, R., Hahlbohm, H.-D., Lehmann, H. P., & Trontelj, Z. (1983) · Journal of Electrocardiology · doi:10.1016/s0022-0736(83)80085-5 · Cited by 12 · see citing works
Self-citationMagnetocardiography in patients with acute chest pain and bundle branch block
Leithäuser, B., Park, J.-W., Hill, P., Lam, Y.-Y., & Jung, F. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.254 · Cited by 11 · see citing works
Göudde, P., Agrawal, R., Müuller, H. ‐., Czerski, K., ENDT, P., Steinhoff, U., Oeff, M., Schultheiß, H., & Behrens, S. (2001) · Clinical Cardiology · doi:10.1002/clc.4960241009 · Cited by 11 · see citing works
Desai, L., Wakai, R. T., Tsao, S. S. L., Strasburger, J. F., Gotteiner, N. L., & Patel, A. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13900 · Cited by 11 · see citing works
Lombardi, G., Sorbo, A. R., Guida, G., La Brocca, L., Fenici, R., & Brisinda, D. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.02.004 · Cited by 10 · see citing works
Self-citationFrom 3D to 4D imaging: is that useful for interventional cardiac electrophysiology?
Fenici, R., & Brisinda, D. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353714 · Cited by 10 · see citing works
Self-citationHuang, X., Hua, N., Tang, F., & Zhang, S. (2020) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt-20-121 · Cited by 10 · see citing works
Guida, G., Sorbo, A. R., Fenici, R., & Brisinda, D. (2018) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12569 · Cited by 9 · see citing works
Self-citationPredictive value of rest magnetocardiography in patients with stable angina
Fenici, R., & Brisinda, D. (2007) · International Congress Series · doi:10.1016/j.ics.2007.02.022 · Cited by 8 · see citing works
Self-citationComparison of clinical-based and ECG-based triage of acute chest pain in the Emergency Department
Dechamps, M., Castanares‐Zapatero, D., Berghe, P. V., Meert, P., & Manara, A. (2016) · Internal and Emergency Medicine · doi:10.1007/s11739-016-1558-8 · Cited by 8 · see citing works
Fenici, R., Brisinda, D., Nenonen, J., Morana, G., & Fenici, P. (2001) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2001.46.s2.219 · Cited by 8 · see citing works
Self-citationClassification of magnetocardiographic parameters based on the probability density function
Kwon, H.-C., Lim, H. K., Kim, J. M., Kim, K., Chung, N., Kim, T. E., Lee, Y., & Ko, Y. (2006) · Journal of the Korean Physical Society · Cited by 8 · see citing works
Current density imaging of focal cardiac sources
Nenonen, J., Pesola, K., Feneici, R., Lauerma, K., Mäkijärvi, M., & Katila, T. (2001) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2001.46.s2.50 · Cited by 7 · see citing works
Mäkijärvi, M. A., Korhonen, P., Jurkko, R., Väänänen, H., SILTANEN, P., & Hänninen, H. (2010) · Springer eBooks · doi:10.1007/978-1-84882-046-3_44 · Cited by 7 · see citing works
Fenici, R., Mashkar, R., & Brisinda, D. (2020) · European Heart Journal · doi:10.1093/ehjci/ehaa946.0386 · Cited by 7 · see citing works
Self-citationAn approach to clinical magnetocardiology.
AWANO, I., MURAMOTO, A., & Awano, N. (1982) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.138.367 · Cited by 6 · see citing works
Goernig, M., Haueisen, J., Schreiber, J., LEDER, U., Hänninen, H., Mäkelä, T. J., Takala, P., Nenonen, J., Lauerma, K., Knuuti, J. M., et al. (2008) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2008.09.002 · Cited by 6 · see citing works
Magnetoenterography for the Detection of Partial Mesenteric Ischemia
Somarajan, S., Muszynski, N. D., Olson, J. D., Bradshaw, L. A., & Richards, W. O. (2019) · Journal of Surgical Research · doi:10.1016/j.jss.2019.01.034 · Cited by 6 · see citing works
Magnetocardiography capabilities in myocardium injuries diagnosis
Sosnytskyy, V., Chaikovsky, I. A., Stadnyuk, L., Miasnykov, G., Kazmirchyk, A., Sosnytska, T., & Gurjeva, O. (2013) · World Journal of Cardiovascular Diseases · doi:10.4236/wjcd.2013.35059 · Cited by 5 · see citing works
Noninvasive detection of myocardial ischemia: A case of magnetocardiography
Shin, E., Ann, S. H., Brachmann, J., Lam, Y., Jung, F., & Park, J. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-151945 · Cited by 5 · see citing works
Sosnytskyy, V., Stadnyuk, L. A., Sosnytska, T., Кожухов, С. Н., & Мясников, Г. В. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx493.p5502 · Cited by 4 · see citing works
Tolstrup, K., Brisinda, D., Meloni, A., Cheung, B. M. Y., Siegel, R., & Fenici, R. (2006) · Cited by 4 · see citing works
Self-citationTamaki, W., Tsuda, E., Hashimoto, S., Toyomasa, T., & Fujieda, M. (2019) · Heart and Vessels · doi:10.1007/s00380-019-01383-4 · Cited by 4 · see citing works
Kashyap, R., Smars, P. A., Gartzen, C., Bellolio, M. F., & Reeder, G. (2008) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2008.01.133 · Cited by 3 · see citing works
Self-citationChaikovsky, I. A., Primin, M., Владимирович, Н. И., Verba, A., Mjasnikov, G., Kazmirchyk, A., Ji, W., Fan, X., Tan, X., Lei, M., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.309 · Cited by 2 · see citing works
Flüg, M., Achenbach, S., Moshage, W. E. L., Schubert, J., & Bachmann, K. (1997) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1997.42.s2.241 · Cited by 1 · see citing works
Tamaki, W., Tsuda, E., Hashimoto, S., Toyomasa, T., & Fujieda, M. (2019) · Heart and Vessels · doi:10.1007/s00380-019-01409-x · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 71 · see citing works
Self-citationFenici, R., Picerni, M., Fenici, P., & Brisinda, D. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100514 · Cited by 7 · see citing works
Self-citationWearable Wireless Dual-Plane OPM-MCG System for Rest/Stress Cardiac Magnetic Field Measurement
Li, T., Cheng, H., Wang, D., Yin, Y., Li, C., Gu, W., Jiang, C., Lyu, B., & Gao, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3595239 · Cited by 1 · see citing works
Classification of current density vector map using transformer hybrid residual network
Zhu, L., Yang, Y., Yu, W., Zeng, Q., Zheng, Z., Lin, Q., Zhao, X., & Hu, Z. (2025) · PLoS ONE · doi:10.1371/journal.pone.0338189 · Cited by 1 · see citing works
Coriasso, N., & Daher, E. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100425 · Cited by 1 · see citing works
Analytical Sampling Bounds and Hexagonal Topology for Magnetocardiography Sensor ArraysPreprint
Zhang, A., (49484), X. Z., Yang, J., Tian, K., Chen, W., & Zheng, Q. S. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6890083
- Authors
- Brisinda, D., Fenici, R., & Smars, P.
- Affiliations
- Università Cattolica del Sacro Cuore (IT)
- Mayo Clinic (US)
- Corresponding author
- Smars, Peter
- Venue
- Contemporary Cardiology
- Publisher
- Springer International Publishing
- Published
- 2022
- Pages
- 177-213
- ISSN
- 2196-8969 (ISSN-L)
- 2196-8977
- OpenAlex
- W4293461986
- Cited by
- 6
- References
- 145
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 1
- FWCI
- 7.77
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Contemporary cardiology (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- magnetocardiography, acute coronary syndrome, chest pain, ischemic heart disease, missed diagnosis, high-sensitivity troponin, emergency department disposition, atypical presentation, cardiac biomarkers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review