Magnetocardiography and exercise testing
The DOI matches its Crossref record; 6 of the 7 references it cites were found in a registry or an index.
Abstract
Twenty healthy male subjects (age range, 15-25 years; median, 21 years) underwent magnetocardiography during physical exercise. Significant ST-segment displacements of the magnetic signal were found during exercise at a heart rate of 120 beats/min compared to the magnetic signal at rest (P < .001). Since no significant ST-segment changes were found in the electrocardiogram recorded simultaneously with the magnetocardiogram, it is concluded that the magnetocardiogram shows junctional ST-T segment changes earlier than the electrocardiogram.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The exercise ECG (eECG), which records the electrical signal of patients in exercise, is a widely used diagnostic procedure in the evaluation of both normal participants and cardiologic patients with coronary heart disease (13–16).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [14]
In the citing paper
“However, despite the great clinical significance of movable MCG systems, few studies have been reported (14, 15, 23–27).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [14]
Citations
Cites
Biomagnetism: Clinical Aspects
Hoke, M. (1992) · Cited by 235
Cohen, D., & Kaufman, L. A. (1975) · Circulation Research · doi:10.1161/01.res.36.3.414 · Cited by 131
Fox, K. M., Selwyn, A. P., Oakley, D., & Shillingford, J. P. (1979) · The American Journal of Cardiology · doi:10.1016/0002-9149(79)90171-1 · Cited by 73
Toward the optimal lead system and optimal criteria for exercise electrocardiography
Simoons, M. L., & Block, P. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90270-8 · Cited by 47
Biomagnetometry: imaging the heart's magnetic field.
Hart, G. (1991) · Heart · doi:10.1136/hrt.65.2.61 · Cited by 33
Exercise electrocardiographic mapping in normal subjects
McPherson, D. D., Horacer, B. M., Sutherland, D. J., Armstrong, C., Spencer, C., & Montague, T. J. (1985) · Journal of Electrocardiology · doi:10.1016/s0022-0736(85)80017-0 · Cited by 19
Research works printed but not linked: 1
- Goldhammer, 1933, Elektrokardiographische untersuchungen bei kranken mit angina pectoris, Z Klin Med, 122, 134
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“However, despite the great clinical significance of movable MCG systems, few studies have been reported ( 14 , 15 , 23 – 27 ).”
BROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99
Self-citationAC biosusceptometry in the study of drug delivery
Corá, L. A., Romeiro, F. G., Stelzer, M., Américo, M. F., de Oliveira, R. B., Baffa, O., & Miranda, J. R. D. A. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.01.026 · Cited by 78
Kanzaki, H., Nakatani, S., Kandori, A., Tsukada, K., & Miyatake, K. (2003) · Basic Research in Cardiology · doi:10.1007/s00395-003-0392-0 · Cited by 56
Hänninen, H., Takala, P., Korhonen, P., Oikarinen, L., Mäkijärvi, M., Nenonen, J., Katila, T., & Toivonen, L. (2002) · Annals of Medicine · doi:10.1080/07853890252953518 · Cited by 49
Metadata
- Authors
- Brockmeier, K., Comani, S., Erné, S. N., Di Luzio, S., Pasquarelli, A., & Romani, G. L.
- Affiliations
- Freie Universität Berlin (DE)
- University of Chieti-Pescara (IT)
- National Research Council (IT)
- Venue
- Journal of Electrocardiology
- Publisher
- Elsevier BV
- Published
- 1994-04
- Volume
- 27
- Issue
- 2
- Pages
- 137-142
- ISSN
- 0022-0736 (ISSN-L)
- OpenAlex
- W2036762188
- Cited by
- 24
- References
- 7
- Citations by year
- 2023: 1 · 2022: 1
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Electrocardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- magnetocardiography, exercise testing, ST segment displacement, ST-T segment changes, electrocardiogram comparison, heart rate, exercise-induced changes
- MeSH terms
- Adolescent, Adult, Electrocardiography, Exercise Test, Heart Function Tests, Humans, Magnetics, Male, Exercise
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetocardiography and exercise testing. https://app.cochat.ai/papers/10.1016/s0022-0736(05)80096-2
- The paper
- Brockmeier, K., Comani, S., Erné, S. N., Di Luzio, S., Pasquarelli, A., & Romani, G. L. (1994). Magnetocardiography and exercise testing. Journal of Electrocardiology. https://doi.org/10.1016/s0022-0736(05)80096-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.