The DOI matches its Crossref record.
Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes
Abstract
Spin echoes have been known since 1950. Although their formal description by use of the Bloch equations is straightforward, it does not lead to an intuitive understanding of their behavior except for the special cases of 180° or 90° pulses, especially when many pulses are applied before the magnetization has returned into thermal equilibrium. The extended‐phasegraph algorithm, which takes into account that the total magnetization in spin‐echo sequences is a superposition of many isochromats, allows the recognition of all possible echo signals in arbitrary pulse sequences. Its application to multi‐echo sequences leads to a number of surprising results. It can be demonstrated that refocusing pulses with flip angles much lower than 180° generate an unexpectedly high signal intensity after a few echo periods. Apart from leading to a simple algorithm for the exact calculation of echo intensities in arbitrary multi‐pulse sequences, the phase‐graph algorithm leads to a simple understanding of the contrast behavior of different gradient echo sequences and gives a rational means for the design of MR‐imaging sequences that are free from spurious echoes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Basic principles of diffusion-weighted imaging
Bammer, R. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00303-0 · Cited by 851
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Applications of stimulated echo correction to multicomponent T2 analysis
Prasloski, T., Mädler, B., Xiang, Q., MacKay, A., & Jones, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23157 · Cited by 253
Teixeira, R. P. A. G., Malik, S. J., & Hajnal, J. V. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26670 · Cited by 39
Metadata
- Authors
- Hennig, J.
- Venue
- Concepts in Magnetic Resonance
- Publisher
- Wiley
- Published
- 1991-07
- Volume
- 3
- Issue
- 3
- Pages
- 125-143
- ISSN
- 1043-7347 (ISSN-L)
- 1099-0534
- OpenAlex
- W2165120519
- Cited by
- 241
- References
- 0
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes. https://app.cochat.ai/papers/10.1002/cmr.1820030302
- The paper
- Hennig, J. (1991). Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes. Concepts in Magnetic Resonance. https://doi.org/10.1002/cmr.1820030302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.