Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 253

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Applications of stimulated echo correction to multicomponent T2 analysis

Open access
Prasloski, Thomas, Mädler, Burkhard, Xiang, Qing‐San, MacKay, Alex, Jones, Craig·2012·Magnetic Resonance in Medicine

Abstract

We propose a multicomponent fitting algorithm for multiecho T2 data which allows for correction of T2 distributions in the presence of stimulated echoes. Tracking the population of spins in many coherence pathways via the iterated method of the Extended Phase Graph algorithm allows for accurate quantification of echo magnitudes. The resulting decay curves allow for correction of errors due to nonideal refocusing pulses as a result of inhomogeneities in the B1 transmit field. Non‐Negative Least Squares fitting is used to quantify the magnitude of T2 components at various T2 values. This method, allowing calculation of the T2 distribution with simultaneous extraction of the refocusing pulse flip angle, requires no change to image acquisition procedures and no extra data input. Validation by means of both simulations and in vivo data shows excellent interscan reproducibility while vastly improving the accuracy of extracted T2 parameters in voxels where poor B1 homogeneity leads to refocusing pulse flip angles significantly less than 180°. Most notably, myelin water fraction values in these regions are found to have increased consistency and accuracy. Magn Reson Med, 2011. © 2011 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.23157

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 253

Metadata

Authors
Prasloski, T., Mädler, B., Xiang, Q., MacKay, A., & Jones, C.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2011-10-19
Volume
67
Issue
6
Pages
1803-1814
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2086242446
Cited by
253
References
22
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Applications of stimulated echo correction to multicomponent T2 analysis. https://app.cochat.ai/papers/10.1002/mrm.23157
The paper
Prasloski, T., Mädler, B., Xiang, Q., MacKay, A., & Jones, C. (2012). Applications of stimulated echo correction to multicomponent T2 analysis. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.23157

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.