Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 332

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Yield of endoscopic ultrasound-guided fine-needle aspiration biopsy in patients with suspected pancreatic carcinoma: Emphasis on atypical, suspicious, and false-negative aspirates

Open access
Eloubeidi, Mohamad A., Jhala, Darshana, Chhieng, David C., Chen, Victor K., Eltoum, Isam, Vickers, Selwyn, Mel Wilcox, C., Jhala, Nirag·2003·Cancer

Abstract

BACKGROUND: Although atypical or suspicious cytology may support a clinical diagnosis of a malignancy, it is often not sufficient for the implementation of therapy in patients with pancreatic carcinoma. Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) is a relatively new method for obtaining cytology samples, and one that may decrease the number of atypical/suspicious diagnoses. The goals of the current study were to prospectively evaluate the yield of EUS-FNAB in the diagnosis of patients presenting with solid pancreatic lesions and to evaluate the significance of atypical, suspicious, and false-negative aspirates. METHODS: All patients who presented with a solid pancreatic lesion and underwent EUS-FNAB over a 13-month period were included in the current study. One endoscopist performed all EUS-FNABs. On-site evaluation of specimen adequacy by a cytopathologist was available for each case. Follow-up included histologic correlation (n = 21) and clinical and/or imaging follow-up (n = 80), including 38 patients who died of the disease. RESULTS: EUS-FNABs were obtained from 101 patients (mean age, 62 +/- 11.8 years; age range, 34-89 years). The male-to-female ratio was 2:1. Sixty-five percent of the lesions were located in the head of the pancreas, 12% were located in the uncinate, 17% were located in the body, and 6% were located in the tail. The mean size of the tumors was 3.3 cm (range, 1.3-7 cm). A median of 4 needle passes were performed (range, 1-11 needle passes). Sixty-two biopsies (61.4%) were interpreted as malignant on cytologic evaluation, 5 (5%) as suspicious for a malignancy, 6 (5.9%) as atypical/indeterminate, and 26 (25.7%) as benign processes. Of the 76 malignant lesions, 71 were adenocarcinomas, 3 were neuroendocrine tumors, 1 was a lymphoma, and 1 was a metastatic renal cell carcinoma. All except one of the suspicious/atypical aspirates were subsequently confirmed to be malignant. Agreement was complete for the atypical cases. Among the suspicious cases, 2 of the 5 were identified as carcinoma by one cytopathologist and as suspicious lesions by the other, yielding a 40% disagreement rate between the 2 cytopathologists. Therefore, for the 10 atypical or suspicious cases that later were confirmed to be malignant, the final diagnosis of malignant disease was not made due to scant cellularity that could be attributed to sampling error in 8 cases and to interpretative disagreement in 2 cases (20%). All four false-negative diagnoses were attributed to sampling error. Two percent of all biopsies were inadequate for interpretation. Of the 99 adequate specimens, 72 yielded true-positive results, 23 yielded true-negative results, and 4 yielded false-negative results. No false-positives were encountered. Therefore, the sensitivity, specificity, positive predictive value, and negative predictive value of EUS-FNAB for solid pancreatic masses were 94.7% (95% confidence interval [CI], 89.7-99.8%), 100%, 100%, and 85.2% (95% CI, 71.8-98.6%), respectively. CONCLUSIONS: EUS-FNAB is a safe and highly accurate method for tissue diagnosis of patients with solid pancreatic lesions. Patients with suspicious and atypical EUS-FNAB aspirates deserve further clinical evaluation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cncr.11643

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 332

Metadata

Authors
Eloubeidi, M. A., Jhala, D., Chhieng, D. C., Chen, V. K., Eltoum, I., Vickers, S., Mel Wilcox, C., & Jhala, N.
Venue
Cancer
Publisher
Wiley
Published
2003-09-16
Volume
99
Issue
5
Pages
285-292
ISSN
0008-543X (ISSN-L)
OpenAlex
W1593959916
Cited by
332
References
11
FWCI
6.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Yield of endoscopic ultrasound-guided fine-needle aspiration biopsy in patients with suspected pancreatic carcinoma: Emphasis on atypical, suspicious, and false-negative aspirates. https://app.cochat.ai/papers/10.1002/cncr.11643
The paper
Eloubeidi, M. A., Jhala, D., Chhieng, D. C., Chen, V. K., Eltoum, I., Vickers, S., Mel Wilcox, C., & Jhala, N. (2003). Yield of endoscopic ultrasound-guided fine-needle aspiration biopsy in patients with suspected pancreatic carcinoma: Emphasis on atypical, suspicious, and false-negative aspirates. Cancer. https://doi.org/10.1002/cncr.11643

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.