CoChat

Topographic organization of the orientation column system in large flat‐mounts of the cat visual cortex: A 2‐deoxyglucose study

Löwel, Siegeid, Freeman, Brian, Singer, Wolf · 1987 · Journal of Comparative Neurology
Cited by 124

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

We developed a flat‐mount technique in order to visualize, without additional reconstruction, the system of orientation columns in the cat visual cortex by using 2‐deoxyglucose‐autoradiography. Experimental animals were injected with 2‐deoxyglucose and then stimulated for 45–60 minutes either with vertical or horizontal or oblique gratings alone or with vertical and horizontal gratings presented in alternation. In both areas 17 and 18 stimulation with either vertical or horizontal or oblique stripes produced similar and highly ordered patterns of parallel bands of increased 2‐deoxyglucose uptake that were perpendicular to the boundaries of the areas. In area 17 they occasionally extended without interruption from the 17/18 border on the top of the lateral gyrus to the monocular segment in the splenial sulcus. Superposition of serial sections revealed that these bands were present in all cortical layers and in precise register along lines orthogonal to the lamination. The center‐to‐center spacing of the bands was 1.0–1.1 mm in area 17 and 1.2–1.4 mm in area 18. Stimulation with alternating vertical and horizontal contours led to a pattern the general organization of which resembled that induced by a single orientation but the spacing of which was reduced by a factor of 0.5. This strongly supports the concept that orientation is mapped in a system of parallel bands and argues against a recently formulated hypothesis that iso‐orientation bands extend like spokes from centers that lack orientation selectivity (Braitenberg and Braitenberg, Biol. Cybern, 33:179–186, '79). Another characteristic feature, revealed by the flat‐mount technique, was a periodic variation of 2‐deoxyglucose uptake along the bands that gave them a beaded appearance. The mean center‐to‐center distance between adjacent beads on the same band was in the range of 0.9–1.2 mm and remained unchanged when horizontal and vertical gratings were presented in alternation. We propose that these beads reflect another columnar system whose features have yet to be determined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cne.902550307

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 124

Metadata

Authors
Löwel, S., Freeman, B., & Singer, W.
Venue
Journal of Comparative Neurology
Publisher
Wiley
Published
1987-01-15
Volume
255
Issue
3
Pages
401-415
ISSN
  • 0021-9967 (ISSN-L)
  • 1096-9861
OpenAlex
W1993642737
Cited by
124
References
5
FWCI
5.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.