The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Förster Resonance Energy Transfer Investigations Using Quantum‐Dot Fluorophores
Abstract
Förster resonance energy transfer (FRET), which involves the nonradiative transfer of excitation energy from an excited donor fluorophore to a proximal ground‐state acceptor fluorophore, is a well‐characterized photophysical tool. It is very sensitive to nanometer‐scale changes in donor–acceptor separation distance and their relative dipole orientations. It has found a wide range of applications in analytical chemistry, protein conformation studies, and biological assays. Luminescent semiconductor nanocrystals (quantum dots, QDs) are inorganic fluorophores with unique optical and spectroscopic properties that could enhance FRET as an analytical tool, due to broad excitation spectra and tunable narrow and symmetric photoemission. Recently, there have been several FRET investigations using luminescent QDs that focused on addressing basic fundamental questions, as well as developing targeted applications with potential use in biology, including sensor design and protein conformation studies. Herein, we provide a critical review of those developments. We discuss some of the basic aspects of FRET applied to QDs as both donors and acceptors, and highlight some of the advantages offered (and limitations encountered) by QDs as energy donors and acceptors compared to conventional dyes. We also review the recent developments made in using QD bioreceptor conjugates to design FRET‐based assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabbousi, B. O., Rodriguez-Viejo, J., Mikulec, F. V., Heine, J. R., Mattoussi, H., Ober, R., Jensen, K. F., & Bawendi, M. G. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp971091y · Cited by 4,229
Self-citation
Cited by
Biosensing with Luminescent Semiconductor Quantum Dots
Sapsford, K. E., Pons, T., Medintz, I. L., & Mattoussi, H. (2006) · Sensors · doi:10.3390/s6080925 · Cited by 420
Self-citationRowland, C. E., Fedin, I., Zhang, H., Gray, S. K., Govorov, A. O., Talapin, D. V., & Schaller, R. D. (2015) · Nature Materials · doi:10.1038/nmat4231 · Cited by 288
Advances on fluorescence bioimaging and photo-mediated therapy of NIR-II small molecule dyes
Zhang, W., Laraib, Huo, F., & Yin, C. (2025) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2025.216587 · Cited by 26
Metadata
- Authors
- Clapp, A. R., Medintz, I. L., & Mattoussi, H.
- Venue
- ChemPhysChem
- Publisher
- Wiley
- Published
- 2006-01-11
- Volume
- 7
- Issue
- 1
- Pages
- 47-57
- ISSN
- 1439-4235 (ISSN-L)
- 1439-7641
- OpenAlex
- W2107437823
- Cited by
- 583
- References
- 1
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Förster Resonance Energy Transfer Investigations Using Quantum‐Dot Fluorophores. https://app.cochat.ai/papers/10.1002/cphc.200500217
- The paper
- Clapp, A. R., Medintz, I. L., & Mattoussi, H. (2006). Förster Resonance Energy Transfer Investigations Using Quantum‐Dot Fluorophores. ChemPhysChem. https://doi.org/10.1002/cphc.200500217
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.