The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrodeposition of Nano‐ and Microcrystalline Aluminium in Three Different Air and Water Stable Ionic Liquids
Abstract
The present work shows, for the first time, a comparative experimental study on the electrodeposition of aluminium in three different water and air stable ionic liquids, namely 1‐butyl‐1‐methylpyrrolidinium‐bis(trifluoromethylsulfonyl)imide ([BMP]Tf 2 N), 1‐ethyl‐3‐methylimidazolium‐bis(trifluoromethylsulfonyl)imide ([EMIm] Tf 2 N), and trihexyl‐tetradecyl‐phosphoniumbis(trifluoromethylsulfonyl)imide (P 14,6,6,6 Tf 2 N). The ionic liquids [BMP]Tf 2 N and [EMIm]Tf 2 N show biphasic behaviour in the AlCl 3 concentration range from 1.6 to 2.5 mol L−1 and 2.5 to 5 mol L−1, respectively. The biphasic mixtures become monophasic at temperatures ≥80 °C. It was found that nanocrystalline aluminium can be electrodeposited in the ionic liquid [BMP]Tf 2 N saturated with AlCl 3. The deposits obtained are generally uniform, dense, shining, and adherent with very fine crystallites in the nanometer size regime. However, coarse cubic‐shaped aluminium particles in the micrometer range are obtained in the ionic liquid [EMIm]Tf 2 N. In this liquid the particle size significantly increases as the temperature rises. A very thin, mirrorlike aluminium film containing very fine crystallites of about 20 nm is obtained in the ionic liquid [trihexyl‐tetradecyl‐phosphonium]Tf 2 N at room temperature. At 150 °C, the average grain size is found to be 35 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Air and water stable 1-ethyl-3-methylimidazolium based ionic liquids
Wilkes, J. S., & Zaworotko, M. J. (1992) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39920000965 · Cited by 1,883
Cited by
Applications of ionic liquids in the chemical industry
Plechkova, N. V., & Seddon, K. R. (2008) · Chem. Soc. Rev. · doi:10.1039/b006677j · Cited by 5,686
Ionic-liquid materials for the electrochemical challenges of the future
Armand, M., Endres, F., MacFarlane, D. R., Ohno, H., & Scrosati, B. (2009) · Nature Materials · doi:10.1038/nmat2448 · Cited by 4,619
Self-citationStructure and Nanostructure in Ionic Liquids
Hayes, R., Warr, G. G., & Atkin, R. (2015) · Chemical Reviews · doi:10.1021/cr500411q · Cited by 2,293
An Overview and Future Perspectives of Aluminum Batteries
Elia, G. A., Marquardt, K., Hoeppner, K., Fantini, S., Lin, R., Knipping, E., Peters, W., Drillet, J., Passerini, S., & Hahn, R. (2016) · Advanced Materials · doi:10.1002/adma.201601357 · Cited by 890
Application of ionic liquids to the electrodeposition of metals
Abbott, A. P., & McKenzie, K. J. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b607329h · Cited by 817
Metadata
- Authors
- Zein El Abedin, S., Moustafa, E. M., Hempelmann, R., Natter, H., & Endres, F.
- Venue
- ChemPhysChem
- Publisher
- Wiley
- Published
- 2006-06-30
- Volume
- 7
- Issue
- 7
- Pages
- 1535-1543
- ISSN
- 1439-4235 (ISSN-L)
- 1439-7641
- OpenAlex
- W2132214322
- Cited by
- 223
- References
- 1
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.