The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Make them Blink: Probes for Super‐Resolution Microscopy
Abstract
In recent years, a number of approaches have emerged that enable far‐field fluorescence imaging beyond the diffraction limit of light, namely super‐resolution microscopy. These techniques are beginning to profoundly alter our abilities to look at biological structures and dynamics and are bound to spread into conventional biological laboratories. Nowadays these approaches can be divided into two categories, one based on targeted switching and readout, and the other based on stochastic switching and readout of the fluorescence information. The main prerequisite for a successful implementation of both categories is the ability to prepare the fluorescent emitters in two distinct states, a bright and a dark state. Herein, we provide an overview of recent developments in super‐resolution microscopy techniques and outline the special requirements for the fluorescent probes used. In combination with the advances in understanding the photophysics and photochemistry of single fluorophores, we demonstrate how essentially any single‐molecule compatible fluorophore can be used for super‐resolution microscopy. We present examples for super‐resolution microscopy with standard organic fluorophores, discuss factors that influence resolution and present approaches for calibration samples for super‐resolution microscopes including AFM‐based single‐molecule assembly and DNA origami.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Cited by
Direct stochastic optical reconstruction microscopy with standard fluorescent probes
van de Linde, S., Löschberger, A., Klein, T., Heidbreder, M., Wolter, S., Heilemann, M., & Sauer, M. (2011) · Nature Protocols · doi:10.1038/nprot.2011.336 · Cited by 1,071
Uno, S.-N., Kamiya, M., Yoshihara, T., Sugawara, K., Okabe, K., Tarhan, M. C., Fujita, H., Funatsu, T., Okada, Y., Tobita, S., et al. (2014) · Nature Chemistry · doi:10.1038/nchem.2002 · Cited by 469
Chemistries for DNA Nanotechnology
Madsen, M., & Gothelf, K. V. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00570 · Cited by 447
Ultra-stable organic fluorophores for single-molecule research
Zheng, Q., Juette, M. F., Jockusch, S., Wasserman, M. R., Zhou, Z., Altman, R. B., & Blanchard, S. C. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60237k · Cited by 406
Photophysical processes in single molecule organic fluorescent probes
Stennett, E. M. S., Ciuba, M. A., & Levitus, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60211g · Cited by 323
Metadata
- Authors
- Vogelsang, J., Steinhauer, C., Forthmann, C., Stein, I. H., Person‐Skegro, B., Cordes, T., & Tinnefeld, P.
- Venue
- ChemPhysChem
- Publisher
- Wiley
- Published
- 2010-08-16
- Volume
- 11
- Issue
- 12
- Pages
- 2475-2490
- ISSN
- 1439-4235 (ISSN-L)
- 1439-7641
- OpenAlex
- W2126616934
- Cited by
- 199
- References
- 3
- FWCI
- 13.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Make them Blink: Probes for Super‐Resolution Microscopy. https://app.cochat.ai/papers/10.1002/cphc.201000189
- The paper
- Vogelsang, J., Steinhauer, C., Forthmann, C., Stein, I. H., Person‐Skegro, B., Cordes, T., & Tinnefeld, P. (2010). Make them Blink: Probes for Super‐Resolution Microscopy. ChemPhysChem. https://doi.org/10.1002/cphc.201000189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.