Mechanobiology in Lung Epithelial Cells: Measurements, Perturbations, and Responses
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Epithelial cells of the lung are located at the interface between the environment and the organism and serve many important functions including barrier protection, fluid balance, clearance of particulate, initiation of immune responses, mucus and surfactant production, and repair following injury. Because of the complex structure of the lung and its cyclic deformation during the respiratory cycle, epithelial cells are exposed to continuously varying levels of mechanical stresses. While normal lung function is maintained under these conditions, changes in mechanical stresses can have profound effects on the function of epithelial cells and therefore the function of the organ. In this review, we will describe the types of stresses and strains in the lungs, how these are transmitted, and how these may vary in human disease or animal models. Many approaches have been developed to better understand how cells sense and respond to mechanical stresses, and we will discuss these approaches and how they have been used to study lung epithelial cells in culture. Understanding how cells sense and respond to changes in mechanical stresses will contribute to our understanding of the role of lung epithelial cells during normal function and development and how their function may change in diseases such as acute lung injury, asthma, emphysema, and fibrosis. © 2012 American Physiological Society.Compr Physiol 2:1‐29, 2012.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Molecular Mechanisms of Stress-Responsive Changes in Collagen and Elastin Networks in Skin
Aziz, J., Shezali, H., Radzi, Z., Yahya, N. A., Abu Kassim, N. H., Czernuszka, J., & Rahman, M. T. (2016) · Skin Pharmacology and Physiology · doi:10.1159/000447017 · Cited by 7,323
The Acute Respiratory Distress Syndrome
Ware, L. B., & Matthay, M. A. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421806 · Cited by 4,666
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Cell Migration: A Physically Integrated Molecular Process
Lauffenburger, D. A., & Horwitz, A. F. (1996) · Cell · doi:10.1016/s0092-8674(00)81280-5 · Cited by 3,915
Chronic Obstructive Pulmonary Disease
Barnes, P. J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007273430407 · Cited by 1,078
Cell prestress. I. Stiffness and prestress are closely associated in adherent contractile cells
Wang, N., Tolić-Nørrelykke, I. M., Chen, J., Mijailovich, S. M., Butler, J. P., Fredberg, J. J., & Stamenović, D. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00269.2001 · Cited by 669
Cyclic stretch-induced reorganization of the cytoskeleton and its role in enhanced gene transfer
Geiger, R. C., Taylor, W., Glucksberg, M. R., & Dean, D. A. (2006) · Gene Therapy · doi:10.1038/sj.gt.3302693 · Cited by 64 · cited 1×
“It is interesting to note that studies using A549 cells suggest a higher tolerance for mechanical stretch compared with primary cells, as stretch between 10% and 16% for 24 h failed to induce changes in cell viability or apoptosis (99, 165).”
Cited by
Integrins as biomechanical sensors of the microenvironment
Kechagia, J. Z., Ivaska, J., & Roca-Cusachs, P. (2019) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-019-0134-2 · Cited by 1,311
Critical Power: An Important Fatigue Threshold in Exercise Physiology
POOLE, D. C., BURNLEY, M., VANHATALO, A., ROSSITER, H. B., & JONES, A. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000939 · Cited by 535
A lung-on-a-chip array with an integrated bio-inspired respiration mechanism
Stucki, A. O., Stucki, J. D., Hall, S. R. R., Felder, M., Mermoud, Y., Schmid, R. A., Geiser, T., & Guenat, O. T. (2015) · Lab on a Chip · doi:10.1039/c4lc01252f · Cited by 410
Tensile Forces and Mechanotransduction at Cell–Cell Junctions
Charras, G., & Yap, A. S. (2018) · Current Biology · doi:10.1016/j.cub.2018.02.003 · Cited by 405
Muscle oxygen transport and utilization in heart failure: implications for exercise (in)tolerance
Poole, D. C., Hirai, D. M., Copp, S. W., & Musch, T. I. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00943.2011 · Cited by 285
Metadata
- Authors
- Waters, C. M., Roan, E., & Navajas, D.
- Venue
- Comprehensive Physiology
- Publisher
- Wiley
- Published
- 2012-01
- Volume
- 2
- Issue
- 1
- Pages
- 1-29
- ISSN
- 2040-4603 (ISSN-L)
- OpenAlex
- W1607599317
- Cited by
- 123
- References
- 8
- Type
- other
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.