Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Venous System: Physiology of the Capacitance Vessels

Rothe, Carl F.·1983·Comprehensive Physiology

Abstract

The sections in this article are: 1 Synopsis 2 Perspectives 3 Definitions and Basic Concepts 3.1 Definitions 3.1.1 Capacitance 3.1.2 Capacitance Vessels 3.1.3 Capacity 3.1.4 Compliance 3.1.5 Distensibility 3.1.6 Resistance Vessels 3.1.7 Stressed Volume 3.1.8 Unstressed Volume 3.1.9 Venoconstriction 3.1.10 Venous Return 3.1.11 Viscoelastic Properties 3.2 Active Contraction of Veins 3.3 Effect of Flow on Vascular Volume 3.4 Central Venous Pressure 3.5 Mean Circulatory Filling Pressure 3.6 Venous Hemodynamics 3.7 Venous Resistance 4 Structural Characteristics of Veins 4.1 Anatomy 4.1.1 Innervation 4.1.2 Venous Valves 4.2 Volume of Blood 4.3 Vascular Compliance 4.3.1 Total Body 4.3.2 Arterial Bed 4.3.3 Pulmonary Bed 4.3.4 Liver 4.3.5 Intestine 4.3.6 Spleen 4.3.7 Limbs 4.4 Linearity of Pressure-Volume Relationship 5 Venous Return and Potential Role of Veins in Cardiovascular Homeostasis 5.1 Guytonian Relationship Between Venous Return and Cardiac Output 5.2 De Jager-Krogh Phenomenon 5.3 Venous Pooling on Standing 6 Reflex Control of Capacitance System 6.1 Effect of Neural and Hormonal Stimulation 6.2 Baroreceptors 6.2.1 Early Studies 6.2.2 General Systemic Venoconstriction 6.2.3 Splanchnic Bed 6.3 Chemoreceptors 6.4 Atrial, Ventricular, and Pulmonary Receptors 6.5 Receptor Interaction 6.6 Venous Myogenic Activity 6.7 Venoarteriolar Reflex 6.8 Effect of Temperature 6.9 Time Course of Reflex Response 6.10 Capacitance-Vessel Tone 7 Veins in Health and Disease 7.1 Exercise 7.2 Vasovagal Syncope 7.3 Orthostatic Hypotension 7.4 Shock 7.4.1 Hemorrhage 7.4.2 Cardiogenic Shock 7.4.3 Endotoxin 7.5 Hypertension 8 Methods of Measurement of Vascular Capacitance 8.1 Transmural Pressure of Capacitance Vessels 8.2 Volume of Capacitance Vessels 8.2.1 Visual and Direct Observations 8.2.2 Plethysmography and Weighing 8.2.3 Tissue Radioactivity Monitoring 8.2.4 Indicator Mean Transit Time 8.2.5 Integral of Inflow Minus Outflow 8.2.6 Pressure of Isolated Vascular Segment or Organ; Zero Inflow 8.2.7 Pressure Gradient Along Perfused Isolated Vein 8.2.8 Changing Pressure During Temporary Venous Occlusion 8.2.9 Time Constant 8.2.10 Oscillations in Volume 8.3 Measures of Total-Body Vascular Compliance and Capacitance 8.3.1 Pump-Bypass and Reservoir Technique 8.3.2 Pump-Bypass, Closed-System Approach 8.3.3 Mean Circulatory Filling Pressure 8.4 General Problems 8.4.1 Trauma and Anesthesia 8.4.2 Lumped Parameters 8.4.3 Differences Between Tissues 8.4.4 Transmural Pressure 8.4.5 Passive Changes 8.4.6 Arterial Compliance 8.4.7 Transcapillary Fluid Shifts 8.4.8 Albumin and Erythrocyte Space 8.4.9 Saturation of Response 9 Pharmacology of Veins 9.1 Anesthetics 9.2 Angiotensin 9.3 Catecholamines 9.4 Histamine 9.5 Morphine 9.6 Nitroprusside 9.7 Serotonin 9.8 Vasopressin 10 Future Research

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cphy.cp020313

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 197

Metadata

Authors
Rothe, C. F.
Venue
Comprehensive Physiology
Publisher
Wiley
Published
1983-12
Pages
397-452
ISSN
2040-4603 (ISSN-L)
OpenAlex
W1601395312
Cited by
197
References
2
Type
other
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.