Modulated Ionomer Distribution in the Catalyst Layer of Polymer Electrolyte Membrane Fuel Cells for High Temperature Operation
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Ionomer distribution is an important design parameter for high performance polymer electrolyte membrane fuel cells (PEMFCs); however, the nano‐scale modulation of the ionomer morphology has not been intensively explored. Here, we propose a new route to modulate the ionomer distribution that features the introduction of poly(ethylene glycol) (PEG) to the cathode catalyst layer and the leaching the PEG phase from the catalyst layer using a water effluent during operation. The key concept in the approach is the expansion of the ionomer thin film through the PEG addition. We demonstrate that the modulated ionomer distribution increases the electrochemical active area and proton transport property, without loss in oxygen transport, at a fixed ionomer content. At a high temperature of 120 °C, the power performance at 0.6 V is increased by 1.73‐fold with the modulated ionomer distribution as a result of 1.25‐fold increase in the electrochemical active area and two‐fold increase in the proton transport rate in the catalyst layer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuel Cell Catalyst Layers: A Polymer Science Perspective
Holdcroft, S. (2014) · Chemistry of Materials · doi:10.1021/cm401445h · Cited by 481
Passalacqua, E., Lufrano, F., Squadrito, G., Patti, A., & Giorgi, L. (2001) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00679-4 · Cited by 440
Soboleva, T., Zhao, X., Malek, K., Xie, Z., Navessin, T., & Holdcroft, S. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am900600y · Cited by 424
Optimum Nafion content in PEM fuel cell electrodes
Sasikumar, G., Ihm, J. W., & Ryu, H. (2004) · Electrochimica Acta · doi:10.1016/j.electacta.2004.01.126 · Cited by 187
Microstructure of Catalyst Layers in PEM Fuel Cells Redefined: A Computational Approach
Malek, K., Mashio, T., & Eikerling, M. (2011) · Electrocatalysis · doi:10.1007/s12678-011-0047-0 · Cited by 151
Su, L., Jia, W., Li, C., & Lei, Y. (2014) · ChemSusChem · doi:10.1002/cssc.201300823 · Cited by 109
Cited by
Nguyen, H., Klose, C., Metzler, L., Vierrath, S., & Breitwieser, M. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202103559 · Cited by 133
Doo, G., Lee, J. H., Yuk, S., Choi, S., Lee, D.-H., Lee, D. W., Kim, H. G., Kwon, S. H., Lee, S. G., & Kim, H.-T. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b01751 · Cited by 126
Self-citationLee, J. H., Doo, G., Kwon, S. H., Kang, H., Choi, S., Yim, S.-D., Kim, H.-T., & Lee, S. G. (2020) · ACS Applied Polymer Materials · doi:10.1021/acsapm.0c00042 · Cited by 27
Self-citationSo, S., Kang, H., Choi, D., & Oh, K.-H. (2020) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2020.05.128 · Cited by 20
Self-citation
Metadata
- Authors
- Choo, M., Oh, K., Kim, H., & Park, J.
- Venue
- ChemSusChem
- Publisher
- Wiley
- Published
- 2014-04-28
- Volume
- 7
- Issue
- 8
- Pages
- 2335-2341
- ISSN
- 1864-5631 (ISSN-L)
- 1864-564X
- OpenAlex
- W2110739553
- Cited by
- 29
- References
- 6
- FWCI
- 0.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.