Sequential immunofluorescence staining and image analysis for detection of large numbers of antigens in individual cell nuclei
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Visualization of more than one antigen by multicolor immunostaining is often desirable or even necessary to explore spatial and temporal relationships of functional significance. Previously presented staining protocols have been limited to the visualization of three or four antigens. Methods: Immunofluorescence staining was performed both on slices of formalin‐fixed tissue and on cells in culture. Images of the stained material were recorded using digital imaging fluorescence microscopy. The primary and secondary antibodies, as well as the fluorophores, were thereafter removed using a combination of denaturation and elution techniques. After removal of the fluorescence stain, a new immunofluorescence staining was performed, visualizing a new set of antigens. The procedure was repeated up to three times. A method for image registration combined with segmentation, extraction of data, and cell classification was developed for efficient and objective analysis of the image data. Results: The results show that immunofluorescence stains in many cases can be repeatedly removed without major effects on the antigenicity of the sample. Conclusions: The concentration of at least six different antigens in each cell can thus be measured semiquantitatively using sequential immunofluorescence staining and the described image analysis techniques. The number of antigens that can be visualized in a single sample is considerably increased by the presented protocol. Cytometry 47:32–41, 2002. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vandesande, F., & Dierickx, K. (1975) · Cell and Tissue Research · doi:10.1007/bf00218970 · Cited by 496 · cited 1×
“buffer (7), dimethylformamide (18), glycine and dimeth-”
Cited by
Structural and molecular interrogation of intact biological systems
Chung, K., Wallace, J., Kim, S.-Y., Kalyanasundaram, S., Andalman, A. S., Davidson, T. J., Mirzabekov, J. J., Zalocusky, K. A., Mattis, J., Denisin, A. K., et al. (2013) · Nature · doi:10.1038/nature12107 · Cited by 2,008
Highly multiplexed imaging of tumor tissues with subcellular resolution by mass cytometry
Giesen, C., Wang, H. A. O., Schapiro, D., Zivanovic, N., Jacobs, A., Hattendorf, B., Schüffler, P. J., Grolimund, D., Buhmann, J. M., Brandt, S., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2869 · Cited by 1,951
Methods and applications for single-cell and spatial multi-omics
Vandereyken, K., Sifrim, A., Thienpont, B., & Voet, T. (2023) · Nature Reviews Genetics · doi:10.1038/s41576-023-00580-2 · Cited by 1,244
Multiplexed ion beam imaging of human breast tumors
Angelo, M., Bendall, S. C., Finck, R., Hale, M. B., Hitzman, C., Borowsky, A. D., Levenson, R. M., Lowe, J. B., Liu, S. D., Zhao, S., et al. (2014) · Nature Medicine · doi:10.1038/nm.3488 · Cited by 1,108
Micheva, K. D., & Smith, S. J. (2007) · Neuron · doi:10.1016/j.neuron.2007.06.014 · Cited by 787
“While antibody elution is not a new method (for example, Kolodziejczyk and Baertschi [1986], Tramu et al. [1978], Wahlby et al. [2002] ), it has been limited previously by ultrastructural damage and decrease in antigenicity.”
Metadata
- Authors
- Wählby, C., Erlandsson, F., Bengtsson, E., & Zetterberg, A.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 2001-12-20
- Volume
- 47
- Issue
- 1
- Pages
- 32-41
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2094695556
- Cited by
- 87
- References
- 1
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.